EX72SF: High-Density 26 GHz Modular Microwave Switching, Latch with Self-Terminating Options

FIGURE 1-2: EX72SF (SHOWN WITH A FULL COMPLIMENT OF AGILENT SWITCHES)

The EX72SF is a 2U (3.5”) enclosure that can house up to six Agilent SPDT switches as well as up to six full-size Agilent multi-pole single throw latching terminated or unterminated switches. It can be delivered preconfigured from the factory with twelve switches or can be purchased with less than the full compliment of switches. Additional switches can be added by the customer at later dates. The EX72SF is totally self contained unit with EX7000-OEM board set and ac power supply built into the assembly. Also provided on the EX72SF is a 32-channel, general purpose I/O bus. Access to this bus is through a front panel-mounted 37-pin D-sub connector. Further details on this bus can be found in Section 3.

See Section 3, Basic Operation, for a complete list of Agilent switch modules that can be used with the EX72SF.

EX7400: LXI Based Custom RF Interface Platform

The EX7400 is built around the same internal components as the EX71HD and EX72SF. It starts life as a 4U high and 24” deep rack mountable enclosure. It can be purchased in this configuration allowing a customer to add their own RF and microwave components to the front and rear panels as well as the removable mezzanine that is located at approximately the mid way point between the top and bottom covers. It may also be supplied as a custom or special unit which is preconfigured at the factory with all of the components and inter-connect cabling specified by the customer.

COMMON FEATURES

Preconfigured units, whether an EX71HD, EX72SF, or the EX7400, are delivered with a complete Configuration File that contains all the pertinent details about each programmable device mounted inside. In the case of the EX7400, which may contain internal inter-connect path cabling, the Configuration File also contains all of the point-to-point signal path information. The information included in the Configuration File allows the user to establish a complete signal route by indicating only the end points in a compliant IVI-Switch Connect statement, thus simplifying the programming task.

The EX7000 series assemblies, referred to here after as EX7000, consists of an LXI Class A compliant digital controller interface, one or more 72-channel relay driver board, integral ac power supply, and a selectable assortment of electromechanical microwave switches. More than one relay driver boards are used in custom applications where the internal number of coils exceeds the 72 coil capacity of one relay driver board. As many as four relay driver boards, one plus three

10

EX7000 Series Introduction

Image 10
Contents EX7000 Series VXI Technology, Inc EX7000 Series Preface Table of Contents Section IndexCertification WarrantyLimitation of Warranty Restricted Rights LegendEMC Steve Mauga, QA ManagerService should only be performed by qualified personnel Terms and SymbolsSupport Resources Section IntroductionCommon Features EX7400 LXI Based Custom RF Interface PlatformInteractive Control Populated EX7400 MainframeRelay Drive Control 4JAVA-BASED Graphical User InterfaceExclude Lists Configuration TableRelay Odometer Scan ListsEX7000 Specifications EX72SFOverview Installation LocationUnpacking EX7000 Hardware Setup Driver InstallationNetwork Configuration MAC Address AutoIP Default Address VXI Technology, Inc EX7000 Series Preparation for Use Rear Panel View EX7000 Typical Rear Panel View EX7400Trigger Bus Connectors Digital I/O ConnectorCharacteristic Value General Purpose I/OReset Button Front Panel ViewEX72SF EX7400 WEB page Operation General WEB page OperationPassword Protection EX7000 Main WEBVXI Technology Logo EX7000 Title BlockSoft Front Panel EX7000 Soft Front PanelA pseudorandom fashion until it finds one that is available Dhcp or static IP configurations Time Configuration EX7000 Time Configuration WEB page ManualTime Configuration WEB page Sntp Upgrade Device IdentifyReset RebootTheory of Operation System OverviewRelay Drive Connector Banks OPEN-COLLECTOR VS. TTL Drive LinesRelay Access & Control Continuous ModePulse Mode Continuous Operation ModeIndex