VXI user manual EX7000 Time Configuration WEB page Manual

Page 31

www.vxitech.com

TIME CONFIGURATION

This entry page is used to change the time configuration of the EX7000. By default, the instrument has no notion of “wall-clock” or calendar time. The instrument has no battery-backed clock or any other mechanism to retain time between reboots and power-cycles. By default, the instrument’s time and date at power-up are midnight, January 1, 1970 (the beginning of the “epoch”). The time and date can be manually specified on the Time Configuration page (Figure 4-6). Manual configuration will be necessary if the network environment is such that the instrument cannot reach the Internet. Manual time entry is not affected by the Time Zone control and does not require an instrument reboot to be activated. However, manually-specified time is volatile, and, therefore, must be reentered upon an instrument reboot or power cycle. It is not, however, affected by the Reset page.

FIGURE 4-6: EX7000 TIME CONFIGURATION WEB PAGE – MANUAL

Optionally, the EX7000 supports SNTP (Simple Network Time Protocol), allowing it to receive its time from an SNTP server. The Time Zone control provides a pull-down selection in which the user’s specific time zone is selected. SNTP or PTP (Peer-To-Peer Time Synchronization or IEEE 1588) servers are specified in the Server configuration panel, by IP Address or hostname. An instrument reboot is then required to activate the new selection.

EX7000 Series Web Page Operation

31

Image 31
Contents EX7000 Series VXI Technology, Inc EX7000 Series Preface Table of Contents Index SectionRestricted Rights Legend WarrantyLimitation of Warranty CertificationSteve Mauga, QA Manager EMCTerms and Symbols Service should only be performed by qualified personnelSupport Resources Introduction SectionEX7400 LXI Based Custom RF Interface Platform Common FeaturesPopulated EX7400 Mainframe Interactive Control4JAVA-BASED Graphical User Interface Relay Drive ControlScan Lists Configuration TableRelay Odometer Exclude ListsEX72SF EX7000 SpecificationsOverview Installation LocationUnpacking EX7000 Hardware Setup Driver InstallationNetwork Configuration MAC Address AutoIP Default Address VXI Technology, Inc EX7000 Series Preparation for Use EX7000 Typical Rear Panel View EX7400 Rear Panel ViewDigital I/O Connector Trigger Bus ConnectorsGeneral Purpose I/O Characteristic ValueFront Panel View Reset ButtonEX72SF EX7400 General WEB page Operation WEB page OperationEX7000 Main WEB Password ProtectionEX7000 Title Block VXI Technology LogoEX7000 Soft Front Panel Soft Front PanelA pseudorandom fashion until it finds one that is available Dhcp or static IP configurations EX7000 Time Configuration WEB page Manual Time ConfigurationTime Configuration WEB page Sntp Device Identify UpgradeReboot ResetSystem Overview Theory of OperationOPEN-COLLECTOR VS. TTL Drive Lines Relay Drive Connector BanksContinuous Mode Relay Access & ControlContinuous Operation Mode Pulse ModeIndex