VXI EX7000 user manual EX7400

Page 24

VXI Technology, Inc.

Installation is in the reverse order. Carefully insert the multi-pin white plastic connector, at the end of the switch module cable, into the mating cable extending from the EX72SF enclosure opening. Press the two plastic connectors firmly together until you can feel slight clicking action as the release tab on the enclosure side connector drops into place, locking the two connectors together. Next, align the sides of the carrier with the dark plastic card guides on each side of the rectangular opening. Slide the switch and carrier all the way in until it reaches the rear stop which should place the front body of the connector approximately flush with the front panel of the enclosure. Place the faceplate back in position and secure with the two pan head Philips screws.

To remove a SP4T or SP6T switches from the enclosure, simply remove the four flat head Philips screws from each corner of the switch. Slide the switch forward until it is away from the enclosure and far enough out to access the 16 pin ribbon cable connector plugged into the rear of the switch. Pull the release tab on the rear of the switch away from the connector and pull the ribbon cable connector out of the switch.

Installation is in the reverse order. Carefully insert the ribbon cable connector into the mating connector on the switch module. Align the ribbon cable connector tab with the release tab on the switch’s connector. Press the ribbon cable connector firmly in until the release tab on the switch clicks into place locking the connector in place. Slide the switch all the way in until it the mounting flange is flush with the front panel of the enclosure. The switch can operate in any orientation but the standard configuration is for the #1 port to be closest to the right side of the enclosure which puts port 5 and 6 at the top. Align the four holes and secure with the four flat head Philips head screws.

Following the mechanical installation, the EX72SF needs to have its Configuration file updated. This will not be necessary for cases where a switch is simply replaced with another of the same model. The Configuration file tells the internal control and drive circuitry exactly what is connected to each port of the unit. Updating the Configuration file is accomplished by running the Configurator software tool and following the intuitive prompts. Consult the Configurator User’s manual for details. Alternatively, the new Configuration file can be generated by the factory and downloaded over the Internet. Consult the factory for details.

EX7400

Generally speaking, most EX7400 models will have their switches mounted internally and are not intended for easy field upgrades or repairs. Please contact the VTI Microwave in the event of a failure.

24

EX7000 Series Basic Operation

Image 24
Contents EX7000 Series VXI Technology, Inc EX7000 Series Preface Table of Contents Section IndexWarranty Limitation of WarrantyCertification Restricted Rights LegendEMC Steve Mauga, QA ManagerService should only be performed by qualified personnel Terms and SymbolsSupport Resources Section IntroductionCommon Features EX7400 LXI Based Custom RF Interface PlatformInteractive Control Populated EX7400 MainframeRelay Drive Control 4JAVA-BASED Graphical User InterfaceConfiguration Table Relay OdometerExclude Lists Scan ListsEX7000 Specifications EX72SFInstallation Location OverviewUnpacking Driver Installation EX7000 Hardware SetupNetwork Configuration MAC Address AutoIP Default Address VXI Technology, Inc EX7000 Series Preparation for Use Rear Panel View EX7000 Typical Rear Panel View EX7400Trigger Bus Connectors Digital I/O ConnectorCharacteristic Value General Purpose I/OReset Button Front Panel ViewEX72SF EX7400 WEB page Operation General WEB page OperationPassword Protection EX7000 Main WEBVXI Technology Logo EX7000 Title BlockSoft Front Panel EX7000 Soft Front PanelA pseudorandom fashion until it finds one that is available Dhcp or static IP configurations Time Configuration EX7000 Time Configuration WEB page ManualTime Configuration WEB page Sntp Upgrade Device IdentifyReset RebootTheory of Operation System OverviewRelay Drive Connector Banks OPEN-COLLECTOR VS. TTL Drive LinesRelay Access & Control Continuous ModePulse Mode Continuous Operation ModeIndex