Omron V400-H111 user manual Performance Data

Page 4

Introduction

Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.

Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PERFORMANCE DATA

Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.

COPYRIGHT AND COPY PERMISSION

This document shall not be copied for sales or promotions without permission.

This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.

Introduction

V400-H111/211

User’s Manual

3

Image 4
Contents USER’S Manual V400-H111/211 Read and Understand this Document Performance Data Meanings of Alert Symbols Meanings of Signal WordsAlert Statements in this Manual Precautions for Safe Use Installation Environment PrecautionsPower Supply and Wiring Precautions Other PrecautionsPrecautions for Correct Use How to Use This Manual FormatVisual Aids Contents System Settings Startup Reading 2D Code Outputting Results FunctionsSection Product Overview Features Readable CodesDual System Lighting Zoom Lens ManualLiquid Crystal Display Memory Card Slot Useful FunctionsData Conversion on Display Data AccumulationInstallation and Connections p.17 System SettingsOperation Overview Reading 2D CodeOperation Overview V400-H111/211 Section Installation and Connections Basic System Configuration Basic system configuration is shown in the following diagramComponent Names and Functions Connecting a Personal Computer V400-W21-2M/5M Cable CableConnecting a Personal Computer V400-W22-2M/5M Cable Connecting a Programmable Controller V400-W20-2M/5M Cable Attach the provided ferrite cores to the cable Connecting Cables to the Handheld 2D Code ReaderRemove the cover from the Code Reader Connect the cable Cable Disconnecting the Cable from the Handheld 2D Code Reader Cable Removing the Cable from the Host Device Connecting the Cable to the Host DeviceRemove the cable Power Supply Connecting the Power Supply V400-W21-2M/5M, V400-W20-2M/5MRecommended Power Supply Connection MethodConnecting the AC Adaptor V400-W22-2M/5M Connect the cable and AC adaptor as shown belowMounting Procedure Removal ProcedureContactor Optional Loosen the four screws to detach the contactorMemory Cards Inserting the Memory CardOpen the Memory Card slot cover Close the Memory Card slot coverRemoving Memory Cards Push the Memory Card in gently until a click is heardMemo Section Reading 2D Code Turn on the power and start the Handheld 2D Code Reader Basic OperationStartup Outputting ResultsStartup BuzzerTrigger Mode Level Trigger Factory settingTrigger Buttons Zoom LeverOutputting Results Monitor DescriptionNormal This area displays images taken by the CameraMode B Mode aMode C Output for Unsuccessful Readings LED IndicatorsRead data is output in the following format Functions SleepSection System Settings Using the LCD monitor Creating the Setting Files OverviewBacking Up Data Uploading DataCreating Setting Files Basic Operation for Setting Mode Making Settings on the Main BodyNext page, to switch between Making Settings on the Main Body V400-H111/211 Starting Setting Mode Setup Screen Start setting modeSelect Setup Setup window structureSelect Communication in the Setup window Change the settingDefault settings are indicated with an asterisk Changing Communication ConditionsSave the setting data Exit communication settingExit setting mode Setting Functions Select Function in the Setup windowExit function setting Starting Setting Mode Uploading from the Memory CardSelect Upload Settings in the menu window Uploading Setting Data to the 2D Code ReaderSelect the data setting file Uploading from the Memory Card V400-H111/211 Select Backup Settings in the menu window Backing Up 2D Code Reader DataRestoring the Factory Setting Data Return the settings to the factory settingsInstalling the 2DCR Configear Click the OK button Click the buttonClick the Continue button Click the OK buttonCommunicating Using 2DCR Configear Communication SettingSetting Reader MenuFile EditDirect Command Input ButtonsDisplay Form Status DisplayCreating Setting Files Using the 2DCR Configear Saves the created data setting fileModelV OpenCommunication Settings Function Settings Level Trigger * or AlternateSection System Settings Data Conversion on Display Setting MethodCreate the CSV file for the display Conversion function Select the desired start position and number of bytes Click 1. New RegistClick the Import button Enter the desired name Click the OK button Select on in Data Conversion on Display fieldDeleting the selected items Deleting Items and Changing Item OrderSwapping the order of the selected items Exit creation of setting data file Save the settingsSaving Sending the Setting File to the 2D Code Reader Click the ConnectS buttonExit the 2DCR Configear Select Setting Reader Send Setting from the menuSelect the desired file and click the Open button Memo Section Troubleshooting Section Troubleshooting Appendices Handling the Handheld 2D Code Reader MaintenanceInspection Handheld 2D Code Reader Specifications and DimensionsV400-H111/211 Appendices Specifications and Dimensions V400-W20-2M/V400-W21-2M CableV400-W20-5M/V400-W21-5M V400-W22-2M V400-W22-5MContactor AC adapterV400-AC2 V600-A22Ascii Table FCS Calculation Method FCS Calculation MethodCalculation Example for Sending FCS Header FooterCalculation Programming Example for Sending FCS FCS Check Subroutine Example for Received DataFollowing diagram, the symbol size is 12 ⋅ Data Capacity TablesDataMatrix DataMatrix ECC200QR Code Following diagram, the symbol size is 21 ⋅ 21 VersionQR Code Model Appendices Data Capacity Tables V400-H111/211 Memo Revision History Cat. No. Z228-E1-01V400-H111/211

V400-H111 specifications

The Omron V400-H111 is a state-of-the-art vision sensor designed for a wide range of applications in industrial automation. This high-performing unit is renowned for its advanced features, which enable manufacturers to enhance productivity and improve quality control in their operations.

One of the leading characteristics of the Omron V400-H111 is its sophisticated image processing capabilities. Equipped with an integrated camera, the vision sensor can perform complex inspections and analysis tasks with remarkable accuracy. The sensor utilizes a powerful algorithm that enables it to detect defects and anomalies in products almost instantaneously. This enhances the overall efficiency of production lines by allowing immediate corrective actions to be taken.

In addition to its robust inspection capabilities, the V400-H111 also offers exceptional flexibility in deployment. It features a compact design that can be easily integrated into various machinery and production setups. The sensor's high degree of adaptability enables it to perform optimally in different lighting conditions and on various surfaces, thus catering to diverse manufacturing environments.

The V400-H111 employs cutting-edge technology such as pattern matching and 1D/2D code reading. These technologies allow the sensor to identify and verify product features with extreme precision. Moreover, the sensor is capable of reading barcodes and QR codes, making it ideal for traceability applications in supply chain management.

Another important aspect of the Omron V400-H111 is its user-friendly interface. The system comes with an intuitive software platform that simplifies the setup and configuration processes. Even operators with limited technical knowledge can easily program the sensor for specific tasks, thereby reducing the training time and increasing operational efficiency.

The durability and reliability of the V400-H111 are further enhanced by its robust construction. Built to withstand the rigors of an industrial environment, the sensor is resistant to dust and moisture, ensuring long-term performance and reduced maintenance requirements.

In summary, the Omron V400-H111 vision sensor is a game-changing tool for manufacturers seeking to optimize their quality control systems. With its powerful image processing capabilities, flexible deployment options, advanced reading technologies, user-friendly interface, and robust construction, it stands out as a premier choice for enhancing production processes.