Overview

DaqBoard/500 Series boards have several software options. Three types of software are available:

Overview …… 4-1Out-ofthe-boxgraphical programs, e.g., DaqView, ViewXL, and post acquisition data analysis programs such as eZ-PostView, eZ-TimeView, and eZ-FrequencyView.

Drivers for Third-party, Icon-driven Software …… 4-2 drivers for third-party, icon-driven software such as LabVIEW.

Out-of-theBoxTMSoftware various language drivers to aid custom programming using API; includes DaqCOMTM ActiveX/COM support.

Out-of-theBoxTMSoftware

Out-of-the-Box programs are convenient for fill-in-the-blank applications that do not require programming for basic data acquisition and display:

DaqView is a Windows-based program for basic set-up and data acquisition. DaqView lets you select desired channels, gains, and a host of other parameters with a click of a mouse. DaqView lets you stream data to disk and display data in numerical or graphical formats.

ViewXL allows you to interface directly with Microsoft Excel to enhance data handling and display. Within Excel you have a full-featured Daq control panel and all the data display capabilities of Excel.

eZ-PostViewprovides a simple method of graphically viewing acquired data. Up to 8 windows can be displayed on one screen, with up to 16 channels overlaid on each window. eZ-PostView makes it simple to visually inspect acquired waveforms from multiple channels within seconds of acquiring the data. Documentation, in Adobe PDF format, is provided on the CD. Refer to the PostAcquisition Analysis.PDF.

eZ-TimeView & eZ-FrequencyView

eZ-TimeView and eZ-FrequencyView are optional post-acquisition analysis packages, which are related to eZ-PostView, but include more features. eZ-TimeView is targeted at time-domain analysis, including min/max, peak-peak, mean, RMS, plus a wide variety of plotting and waveform viewing capabilities. eZ-FrequencyView is targeted at post-acquisition frequency- domain analysis, including FFT’s, octave analysis, plus dozens of other analysis features. Documentation, in Adobe PDF format, is provided on the CD. Refer to the PostAcquisition Analysis.PDF.

The Daq Configuration control panel allows for interface configuration, testing, and troubleshooting.

DaqView can only be used with one DaqBoard at a time.

LabVIEW can be used with multiple boards.

For multiple board use (via custom programming) refer to the Using Multiple Devices section of the Programmer’s Manual or to DaqCOM documentation.

DaqBoard/500 Series

989394

Software and Board Operation 4-1

Image 29
Contents User’s Guide 16-Bit, 200-KHz PCI Data Acquisition BoardsOMB-DAQBOARD-500 Series Shop online atInternet e-mail info@omega.com OMEGAnet Online Service omega.comServicing North America For immediate technical or application assistanceWarnings, Cautions, Notes, and Tips Specifications and Calibration⇒ Programs ⇒ Omega DaqX Software OMB-DAQBOARD-500 Series, Installation Guide 1 - Introduction Table of Contents3 - Configuration 6 - Specifications GlossaryThis product requires one of the following Operating Systems Windows Windows XPInstallation Guide OMB-DAQBOARD-500 SeriesDaqView/500 Authorization Code Reference NoteIMPORTANT Software must be installed before installing hardware Step 1 - Install SoftwareInstallation, A Pictorial Overview Reference Notes2. Remove the PC’s cover. Refer to your PC Owner’s Manual as needed Step 2 - Install Boards in available PCI Bus-slotsIMPORTANT Bus Mastering DMA must be Enabled 9. Secure the board by inserting the rear-panel adapter-plate screw Accessing the DaqBoard/500 Properties Tab Step 3 - Configure BoardsTest Hardware Tab Using “Add Device”Step 4 - Test Hardware Basic Information IntroductionDaqBoard/500 Series User’s Manual Block DiagramDaqBoard/500 Series Block Diagram Timer 0 and Timer Board FeaturesAnalog I/O Digital I/O947294 Overview Connections and PinoutsStandard 68-Pin SCSCI Type III, Socket Female Connector with Orb 68-Pin SCSI Type III PinoutSignal PowerAnalog Input Channels Signal DefinitionsDifferential Channels, Pin Reference HI + Pin #Clocks, Triggers, Counters, and Timers Ground Lines Power LineScrew Terminals for TB2 Side TB-100 Terminal Connector OptionScrew Terminals for TB1 Side 2-6 Connections & PinoutsExternal Connections Connecting User WiringDifferential Channels Screw Terminal Reference HI +Choosing A/D Input Configuration Signal TypesSingle-Ended Configuration Single-EndedDifferential Configuration for Grounded Sources Differential DIFFDifferential for Grounded Signal Sources If the Input Signal is DC Coupled Differential for Floating Signal SourcesIf the Input Signal is AC Coupled Differential Configuration for Floating SourcesConfiguration through Software ConfigurationAnalog Input Configuration ADC RangesDAC OUTPUT DaqBoard/500 DAC Range Resolution DAC RangesRange Configuration Microvolt ResolutionOut-of-theBoxTM Software Software and Board OperationOverview …… Out-of-the-BoxTM Software …… Drivers for Third-party, Icon-driven Software …… DaqCOM Driver ……DaqCOM Driver Drivers for Third-party, Icon-driven SoftwareLabVIEW 4-2 Software and Board OperationProcess Definitions Theory of OperationADC Pacer Clocking Clocking the ADCADC External Event Clocking ADC Maximum Clock RateADC Software Starting Triggering an ADC AcquisitionADC External Gate ADC External TriggerStopping an ADC Acquisition CLOCK ADC Clock and FIFO ErrorsDAC Software Update Digital AcquisitionClocking the DAC DaqBoard/500 Only4-8 Software and Board Operation CE Standards and Directives CE-ComplianceOverview ……5-1 CE Standards and Directives …… Safety Conditions ……5-2 Emissions/Immunity Conditions ……5-2Emissions/Immunity Conditions Safety ConditionsGeneral SpecificationsAnalog Inputs of calibration6-2 Specifications Analog Input Triggering/ClockingAnalog Outputs DaqBoard/500 Only Digital Inputs / OutputsCounter - 1 Counter designated as CNTR1 Physical & Environmentalsingle-ended mode Glossaryreferenced to common Page Page RETURN REQUESTS/INQUIRIES WARRANTY/DISCLAIMERShop online at omega.com 324545A-01OMEGA…Of Course TEMPERATURE