Omega OMB-DAQBOARD-500 Drivers for Third-party, Icon-driven Software, DaqCOM Driver, LabVIEW

Page 30
Drivers for Third-party, Icon-driven Software

Reference Notes:

The software documents: DaqView, ViewXL, and Post Acquisition Data Analysis User’s

Guide, are available in PDF version.

During software installation, Adobe® PDF versions of user manuals will automatically install onto your hard drive as a part of product support. The default location is in the Programs group, which can be accessed from the Windows Desktop. Refer to the PDF documentation for details regarding both hardware and software.

Note that the PDF documents can be read directly from the CD by using the <View PDFs> button located on the opening install screen.

A copy of the Adobe Acrobat Reader® is included on your CD. The Reader provides

a means of reading and printing the PDF documents. Note that hardcopy versions of the manuals can be ordered from the factory.

Drivers for Third-party, Icon-driven Software

DaqView can only be used with one DaqBoard at a time.

LabVIEW can be used with multiple boards.

For multiple board use (via custom programming) refer to the Using Multiple Devices section of the Programmer’s Manual or to DaqCOM documentation.

LabVIEW®

The DaqBoard/500 Series boards are fully supported by our data acquisition VIs for LabVIEW and include engineering data conversion, data display and logging capabilities.

DaqCOM Driver

The DaqCOM™ suite of programming allows applications developers to rapidly develop and deploy custom systems by leveraging COM (Component Object Model) technology. DaqCOM does this by providing a powerful easy-to-use interface to most programming languages including, Visual Basic®, VBA, C++, and J++. In addition, DaqCOM supports the new Windows.NET architecture and includes examples for VisualBasic.NET and C++. Support for VisualStudio.NET is accomplished via the COMInterop feature within VisualStudio.NET.

4-2 Software and Board Operation

988994

DaqBoard/500 Series

Image 30
Contents OMB-DAQBOARD-500 Series 16-Bit, 200-KHz PCI Data Acquisition BoardsUser’s Guide Shop online atServicing North America OMEGAnet Online Service omega.comInternet e-mail info@omega.com For immediate technical or application assistanceSpecifications and Calibration Warnings, Cautions, Notes, and Tips⇒ Programs ⇒ Omega DaqX Software 3 - Configuration Table of ContentsOMB-DAQBOARD-500 Series, Installation Guide 1 - Introduction 6 - Specifications GlossaryWindows Windows XP This product requires one of the following Operating SystemsDaqView/500 Authorization Code OMB-DAQBOARD-500 SeriesInstallation Guide Reference NoteInstallation, A Pictorial Overview Step 1 - Install SoftwareIMPORTANT Software must be installed before installing hardware Reference NotesStep 2 - Install Boards in available PCI Bus-slots IMPORTANT Bus Mastering DMA must be Enabled2. Remove the PC’s cover. Refer to your PC Owner’s Manual as needed 9. Secure the board by inserting the rear-panel adapter-plate screw Step 3 - Configure Boards Accessing the DaqBoard/500 Properties TabUsing “Add Device” Step 4 - Test HardwareTest Hardware Tab Introduction Basic InformationBlock Diagram DaqBoard/500 Series Block DiagramDaqBoard/500 Series User’s Manual Analog I/O Board FeaturesTimer 0 and Timer Digital I/OIntroduction Connections and Pinouts OverviewSignal 68-Pin SCSI Type III PinoutStandard 68-Pin SCSCI Type III, Socket Female Connector with Orb PowerDifferential Channels, Pin Reference Signal DefinitionsAnalog Input Channels HI + Pin #Clocks, Triggers, Counters, and Timers Power Line Ground LinesScrew Terminals for TB1 Side TB-100 Terminal Connector OptionScrew Terminals for TB2 Side 2-6 Connections & PinoutsDifferential Channels Screw Terminal Reference Connecting User WiringExternal Connections HI +Single-Ended Configuration Signal TypesChoosing A/D Input Configuration Single-EndedDifferential DIFF Differential for Grounded Signal SourcesDifferential Configuration for Grounded Sources If the Input Signal is AC Coupled Differential for Floating Signal SourcesIf the Input Signal is DC Coupled Differential Configuration for Floating SourcesAnalog Input Configuration ConfigurationConfiguration through Software ADC RangesRange Configuration DAC RangesDAC OUTPUT DaqBoard/500 DAC Range Resolution Microvolt ResolutionOverview …… Out-of-the-BoxTM Software …… Software and Board OperationOut-of-theBoxTM Software Drivers for Third-party, Icon-driven Software …… DaqCOM Driver ……LabVIEW Drivers for Third-party, Icon-driven SoftwareDaqCOM Driver 4-2 Software and Board OperationTheory of Operation Process DefinitionsADC External Event Clocking Clocking the ADCADC Pacer Clocking ADC Maximum Clock RateADC External Gate Starting Triggering an ADC AcquisitionADC Software ADC External TriggerADC Clock and FIFO Errors Stopping an ADC Acquisition CLOCKClocking the DAC Digital AcquisitionDAC Software Update DaqBoard/500 Only4-8 Software and Board Operation Overview ……5-1 CE Standards and Directives …… Safety Conditions ……5-2 CE-ComplianceCE Standards and Directives Emissions/Immunity Conditions ……5-2Safety Conditions Emissions/Immunity ConditionsAnalog Inputs SpecificationsGeneral of calibrationAnalog Input Triggering/Clocking 6-2 SpecificationsDigital Inputs / Outputs Analog Outputs DaqBoard/500 OnlyPhysical & Environmental Counter - 1 Counter designated as CNTR1Glossary single-ended modereferenced to common Page Page WARRANTY/DISCLAIMER RETURN REQUESTS/INQUIRIESOMEGA…Of Course 324545A-01Shop online at omega.com TEMPERATURE