Omega 1002 manual Trigger Method Selection

Page 34

3.2.2.8.2 Trigger Method Selection

There are several trigger methods that can be selected by the user (see section 1.4.5):

[Bit1,Bit0 ]

Descriptions

[ 0, 0 ]

General trigger mode.

 

8254 timer 0 trigger (internal pacer trigger ) or software

 

trigger.

[ 0, 1 ]

External clock trigger mode.

[ 1, 0 ]

Pre-trigger mode.

[ 1, 1 ]

Post-trigger mode.

Note:

1.In the general trigger mode, both the 8254 timer 0 and the software trigger are used as the A/D trigger signals. The timer 0 and the software trigger should not be used at the same time! This means the user should not generate a software trigger while the 8254 timer 0 is activated!

2.In the external clock trigger mode, an external input is taken as the A/D trigger signal. A single falling edge of the external trigger will generate a single A/D trigger.

3.The pre-trigger mode employs the 8254 timer 1. The user should first configure timer 1, then set the trigger mode to pre-trigger. Once the pre-trigger mode has been activated, it will automatically turn on timer 1 and start the A/D trigger. This will continue until a falling edge from an external trigger signal is received. Any change to the trigger mode selection will turn off the pre-trigger mode.

4.The post-trigger mode employs the 8254 timer 1. The user should first configure timer 1, then set the trigger mode to post-trigger. Once the post-trigger mode has been activated, it will automatically turn off the timer 1 until it receives a falling edge from an external signal. Any change to the trigger mode selection will turn off the post-trigger mode.

5.The A/D trigger selection is set to 0 after power-on or hardware reset.

34

Image 34
Contents User’sGuide Servicing North America Table of Contents Software and Demo Program Diagnostic Program Introduction General DescriptionBlock Diagram X86 SystemFeatures Power Consumption SpecificationsAnalog Inputs 3 D/I and D/O 4 A/D Trigger MethodsProgrammable Timer/Counter Interrupt ChannelApplications OME-PCI-1002 series multifunction cardsProduct Check List Release NotesHardware Configuration Board LayoutJumper Setting A/D CalibrationSystem Block Diagram OME-PCI-1002 System Function BlockDaughter Boards OME-DB-8225 OME-DB-37OME-DB-16P Isolated Input Board OME-DB-16R Relay Board Analog Input Signal Connection Page Page Signal Shielding Jumper Settings Connectors Page How to Find the I/O Address O RegistersPage I/O Address Map Section 8254 Registers Status Register Clear Interrupt General Control Register Interrupt Source SelectionTrigger Method Selection Function Operation Digital I/O8254 Timer A/D triggerSymbol Name Minimum Maximum A/D Conversion CPUSuggested Settling Times 1 A/D Conversion Trigger Modes Software Trigger and Polling Techniques Page Page Software and Demo Program Power-ON Plug & Play Test Driver Plug & Play TestD I/O Test A/D TestWARRANTY/DISCLAIMER Temperature