1.4 Specifications

1.4.1 Power Consumption

+5V @ 960mA maximum, OME-PCI-1002L/H

Operating temperature : 0°C to +70°C

1.4.2 Analog Inputs

Channels: ( software programmable )

32 single-ended inputs/16 differential inputs, jumper selectable.

Gain control : ( software programmable )

OME-PCI-1002H, Gains - 1, 10, 100, 1000.

OME-PCI-1002L, Gains - 1, 2, 4, 8.

Input signal range :

OME-PCI-1002L: Bipolar

Range: ±10, ±5V, ±2.5V, ±1.25V

OME-PCI-1002H: Bipolar

Range: ±10, ±1V, ±0.1V, ±0.01V

Input current: 250 nA max (125 nA typical) at 25 °C.

Over voltage: continuous single channel to 70Vp-p

Input impedance:

OME-PCI-1002H/L: 1010Ω // 6pF

8

Image 8
Contents User’sGuide Servicing North America Table of Contents Software and Demo Program Diagnostic Program Introduction General DescriptionBlock Diagram X86 SystemFeatures Analog Inputs SpecificationsPower Consumption 3 D/I and D/O 4 A/D Trigger MethodsProgrammable Timer/Counter Interrupt ChannelApplications OME-PCI-1002 series multifunction cardsProduct Check List Release NotesHardware Configuration Board LayoutJumper Setting A/D CalibrationSystem Block Diagram OME-PCI-1002 System Function BlockDaughter Boards OME-DB-8225 OME-DB-37OME-DB-16P Isolated Input Board OME-DB-16R Relay Board Analog Input Signal Connection Page Page Signal Shielding Jumper Settings Connectors Page How to Find the I/O Address O RegistersPage I/O Address Map Section 8254 Registers Status Register Clear Interrupt General Control Register Interrupt Source SelectionTrigger Method Selection Function Operation Digital I/O8254 Timer A/D triggerSymbol Name Minimum Maximum A/D Conversion CPUSuggested Settling Times 1 A/D Conversion Trigger Modes Software Trigger and Polling Techniques Page Page Software and Demo Program Power-ON Plug & Play Test Driver Plug & Play TestD I/O Test A/D TestWARRANTY/DISCLAIMER Temperature