Omega Speaker Systems HX93DA, HX93A manual Temperature Adjustment

Page 12

13

HX93A, HX93DA SERIES

RH/Temperature Transmitter

 

 

13.Calibration Procedure for HX93AC (all styles)

Temperature Adjustment

Recommended equipment:

RTD Simulator OMEGA® Model No.: CL510-1

Handheld Digital Multi-meter, OMEGA® Model No.: HHM29

Dc Power Supply, OMEGA® Model No.: PSU-93

1.Remove enclosure cover

2.Connect the power supply and multimeter as shown in the figure below.

3.Disconnect the 2-wire Connector “J4” from the main Board.

4.Connect the RTD simulator to the “J4” header on the main board as shown below.

5.Apply power to transmitter and allow to warm up for 10 min.

6.Set the RTD simulator to the 0ºF position.

7.Adjust potentiometer “P5” on the main board for a output reading of 4.43 mA @ 0°F

8.Set the RTD simulator to the 150ºF position.

9.Adjust potentiometer “P4” for a output reading of 18.46 mA 150°F

10.Repeat steps 6, 7, 8 and 9 as necessary until proper readings are maintained.

11. Calibration complete.

1 2 3

12 3

TB1

TB2

P5

P4

J4

CL-301

SENSOR HEAD

HHM29

18.41 mA

10A uAmA COM V

+24V –

PSU-93

Figure 7 - HX93AC Calibration Procedure

Temperature Adjustment

8

Image 12
Contents User’sGuide Servicing North America For immediate technical or application assistanceServicing Europe HX93A, HX93DA Series SectionRM/Temperature Transmitter HX93A, HX93DA SeriesRH/Temperature Transmitter General DescriptionUnpacking Additional Transmitter Models Available DescriptionExample When using a 24 Vdc power supply Theory of OperationFor HX93A For HX93DA Recommended Accessories MountingComplimentary Instruments Current Transmitter Wiring Examples Electrical ConnectionsVoltage Transmitter Wiring Examples Relative Humidity Output CalculationsTemperature Output Calculations RH Measured Vs Output ReadingFor Current output in ºC -20 to 75ºC Vdc ÷ .005848 4 = 81.5ºFCalibration Procedure for HX93AC all styles Relative Humidity AdjustmentCalibration Recommended equipmentTemperature Adjustment HX93AC Calibration Procedure Temperature AdjustmentCalibration Procedure for HX93AV all styles HX93AV Calibration Procedure Relative Humidity AdjustmentHX93AV Calibration Procedure Temperature Adjustment 15A. Display Scaling for HX93DAC all styles Relative Humidity Display Scaling Recommended equipmentTemperature Display Scaling Recommended equipment For ºF DisplayFor ºC Display Maintenance SpecificationsTemperature Relative HumidityGeneral Specifications DimensionsWeight Wall Mount Model Duct Mount Model Sensor Type Ohm Platinum RTWARRANTY/DISCLAIMER Temperature