Omnitron Systems Technology 8000-0 user manual Port Structure

Page 4

2.0PORT STRUCTURE

2.1OVERVIEW

The Network Management Module front panel provides the access to the Management ports. Management can be accessed through the serial port or the UTP port. The module features a backplane Ethernet port for connectivity to adjacent modules.

Serial Port

Daisy Chain Port

UTP Management Port

2.1.1Serial Console Port

The NMM features a Serial RS-232 Console Port (aka Craft Interface) for the initial setup and configuration described in this manual. The Serial Console Port is accessed through the DB9 female DCE interface.

2.1.2Daisy Chain Ports (Multi-Chassis)

The NMM provides a pair of redundant ports to daisy chain (cascade) up to 19 chassis providing single IP address management.

Multi-Chassis Configuration

To configure a set of chassis for a multi-chassis configuration, the following requirements must be followed:

Only one NMM per chassis

No other management modules can be installed in the chassis (i.e. 10/100M, GX/TM, etc.)

Each NMM must have a unique chassis number (see Section 3.4.1.3)

Remote OAM must be disabled (see Section 3.4.3.2)

Page 4

Image 4
Contents IConverter Network Management Module Table of Contents Overview Port Structure UTP Management Port B B B B B B B Out-of-Band Management Installation Procedure Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting IP Parameters as Dhcp Client Setting NMM Passwords Setting Snmp Preferences Setting the Snmp Trap IP Host Addresses Vlan ID NMM Access the NMM Remotely Updating the NMM Firmware via the Serial Console Port Verify Operation Module Status NMMLED NMM Specifications Troubleshooting Guide Possible CausesWarranty Limitation of Warranty