3.4.1.2Setting IP Parameters as DHCP Client

To configure the IP automatically as a DHCP client, select 9 from the Management Options screen. The Other Networking Features screen will appear.

Management Options

iConverter, Serial Agent

Network Management

 

1: Chassis and Module Management

 

2:

Set Module Identifier

 

Management Module Preferences

 

3: IP and Control Preferences

 

4:

SNMP Preferences

 

5:

Abandon Preference Changes

 

6:

Save Preference Changes

 

7: Restore to Factory Defaults

 

8:

Restart Management Module

 

9:

Other Networking Features

 

Management Module Maintenance

 

10: Firmware Update

 

11: Set Date/Time

 

IP Address

= 192.168.1.220

 

Chassis Number = 1

 

Enter Choice, (H)elp, E(x)it > 9

 

 

 

 

 

 

 

Other Networking Features Screen

iConverter, Serial Agent

1: Enable/Disable DHCP Client

Disabled

2: Enable/Disable Keep Alive Trap

Disabled

3: Keep Alive Trap interval (10-600 secs)

10

4: Serial Baud Rate

57600 bps

5: Enable/Disable Remote OAM

Enable

6: Enable/Disable IP Protocol

Enable

7: Enable/Disable VLAN Support

Disabled

8: VLAN ID (0-4095)

2

9: VLAN Priority (0-7)

7

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

To enable DHCP client, select 1 at the Other Networking Features screen and follow the screen prompts to enable DHCP.

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.

3.4.1.3Setting the Chassis Number and Name

A Chassis Name, or sysName, can be assigned to the NMM for identification to the SNMP management software. The name can be any 1-32 character alphanumeric string.

The Chassis Number can remain as 1 (factory default) when the NMM is installed without another management module (a media converter with integrated management such as the 10/100M) in the same chassis. When the NMM is installed in the same chassis with another management module, they must all be set to the same Chassis Number.

To set the Chassis Number, select 4 at the IP and Control Preferences screen, press <ENTER> and follow the instructions to enter the chassis number.

Page 12

Image 12
Contents IConverter Network Management Module Table of Contents Overview Port Structure UTP Management Port B B B B B B B Out-of-Band Management Installation Procedure Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting IP Parameters as Dhcp Client Setting NMM Passwords Setting Snmp Preferences Setting the Snmp Trap IP Host Addresses Vlan ID NMM Access the NMM Remotely Updating the NMM Firmware via the Serial Console Port Verify Operation Module Status NMMLED NMM Specifications Troubleshooting Guide Possible CausesWarranty Limitation of Warranty