Omnitron Systems Technology 8000-0 user manual Passwords

Page 9

3.4CONFIGURE THE MODULE VIA COMMAND LINE INTERFACE

To configure, attach the NMM to a DB-9 serial (RS-232) equipped computer with terminal emulation software such as HyperTerminal. Using a standard serial cable, connect the serial port of the PC and the Serial Console Port of the NMM. This is a standard asynchronous DCE serial interface. The pin-outs are illustrated below.

 

 

DB-9 Female

 

RD

2

5

1

TD

3

 

 

GND

5

9

6

RTS

7

 

 

Serial Connector Pin Outs

Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:” window. Set the PC’s serial port to the following:

Bits Per Second:

57,600

Stop Bits:

1

Data Bits:

8

Parity:

NONE

Hardware Flow Control:

NONE

Power the chassis containing the NMM and press <ENTER> to bring up a command line prompt on the attached PC.

The module is configured with the following defaults:

IP

 

IP Address:

192.168.1.220

IP Subnet Mask:

255.255.255.0

Passwords

 

Serial:

No password assigned

FTP:

No password assigned

Telnet:

public

SNMPv1/v2c Communities

READ:

public

 

 

WRITE:

public

 

 

SNMPv3 Parameters

 

 

 

User 1 name (read only):

guest

 

 

User 2 name (read/write):

admin

 

 

User 1 Privacy pwd:

publicguest

User 1 Authen pwd:

publicguest

User 2 Privacy pwd:

privateadmin

User 2 Authen pwd:

privateadmin

Page 9

Image 9
Contents IConverter Network Management Module Table of Contents Overview Port Structure UTP Management Port B B B B B B B Out-of-Band Management Installation Procedure Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting IP Parameters as Dhcp Client Setting NMM Passwords Setting Snmp Preferences Setting the Snmp Trap IP Host Addresses Vlan ID NMM Access the NMM Remotely Updating the NMM Firmware via the Serial Console Port Verify Operation NMM Module StatusLED NMM Specifications Possible Causes Troubleshooting GuideLimitation of Warranty Warranty