Omnitron Systems Technology 8000-0 user manual Vlan ID

Page 16

3.4.3Management Support

3.4.3.1VLAN

The NMM Management Processor can independently transmit and receive Management Data with an IEEE 802.1Q tag. To enable and configure this feature, type 9 from the Management Options screen to access the Other Networking Features screen.

Other Networking Features Screen

iConverter, Serial Agent

1: Enable/Disable DHCP Client

Disabled

2: Enable/Disable Keep Alive Trap

Disabled

3: Keep Alive Trap interval (10-600 secs)

10

4: Serial Baud Rate

57600 bps

5: Enable/Disable Remote OAM

Enable

6: Enable/Disable IP Protocol

Enable

7: Enable/Disable VLAN Support

Disabled

8: VLAN ID (0-4095)

2

9: VLAN Priority (0-7)

7

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

To configure the VLAN management ID, select option 8. To configure the priority setting for the VLAN management channel, select option 9. To enable or disable VLAN management support, select option 7.

Once VLAN support is enabled, IP management support will only be accessible using the configured

VLAN ID.

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.

3.4.3.2Remote OAM

Remote OAM (Operations, Administration and Maintenance) allows the NMM to support IP-less management through the IEEE 802.3ah management channel and Omnitron’s secure and encrypted management channel. With IP-less management, an NMM in a chassis at the network core can manage up to 18 iConverter Network Interface Devices (NIDs) at different edge locations with a single IP address. This star configuration with IP-less management requires an NMM in the master chassis, and a media converter with integrated management (such as an iConverter 10/100M) installed at each end of the IP-less managed links

Remote OAM is enabled by default. For multi-chassis cascade configurations, Remote OAM needs to be disabled. To disable/enable Remote OAM, select option 5 from the Other Networking Feature screen.

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.

3.4.4Enabling/Disabling Soft-switch Reload

The Soft-switch Reload function controls the configurations of the NMM and other iConverter modules managed by the NMM following a power up.

When the Soft-switch Reload is disabled, the configurations of the NMM and the other managed modules (non-management modules) are determined by their hardware DIP-switch settings following a return of power. The DIP-switch settings override any previous software settings stored in the FLASH memory of the NMM.

When the Soft-switch Reload is enabled, the configurations of the NMM and the other managed modules are determined by the previous software settings stored in the FLASH memory following a return of power. Each of the module’s hardware DIP-switch settings are ignored until a change is made to the module’s DIP-

Page 16

Image 16
Contents IConverter Network Management Module Table of Contents Overview Port Structure UTP Management Port B B B B B B B Out-of-Band Management Installation Procedure Passwords Management Options screen will be displayed Setting IP and Control Preferences Setting IP Parameters as Dhcp Client Setting NMM Passwords Setting Snmp Preferences Setting the Snmp Trap IP Host Addresses Vlan ID NMM Access the NMM Remotely Updating the NMM Firmware via the Serial Console Port Verify Operation Module Status NMMLED NMM Specifications Troubleshooting Guide Possible CausesWarranty Limitation of Warranty