Omega Vehicle Security PTC900 manual Module 3 Display and Program LOCK-OUT Parameters

Page 16

6.3MODULE 3 - DISPLAY AND PROGRAM LOCK-OUT PARAMETERS ( )

PARAMETER MENU

** These parameters only appear if a Setpoint option card is installed.

= Setpoint Number 1 thru 4

Module 3 is the programming module for setting the Display Lock-out Parameters and the “Quick Programming Mode” Value Access Parameters. In the Quick Programming mode, after the PROGRAM LOCKOUT PARAMETERS

and before the Security Code ( ), a Display Intensity Level ( ) parameter is available when the security code is non-zero. It allows the display intensity to be set to 1 of 16 levels (0-15).

DISPLAY LOCK-OUT PARAMETERS

When operating in the Display Mode, the meter displays can be viewed consecutively by repeatedly pressing the DSP key. The annunciators to the left of the display indicate which display is currently shown. Timer (TMR), Cycle Counter (CNT), or Date (DAT). The Time Display for the Real-Time Clock is shown with no annunciator. Any of these displays can be locked from view with the DISPLAY LOCK-OUT parameters. Using these parameters, each display can be programmed for “Read” or “Lock” defined as follows:

SELECTION

DISPLAY

DESCRIPTION

 

 

 

Read

 

Visible in Display Mode

 

 

 

Lock

 

Not visible in Display Mode

 

 

 

TIMER & CYCLE COUNTER START/STOP VALUE ACCESS

 

«

 

 

«

 

 

«

 

 

«

ª

 

 

ª

 

 

ª

 

 

 

ª

 

 

 

 

 

 

 

 

 

 

Timer & Counter Start/Stop Values can be programmed for

, , or .

PTC901: REAL-TIME CLOCK TIME SETTING ACCESS

«

 

 

 

ª

 

 

 

This parameter can be programmed for

or

. Selecting

allows

setting or changing the RTC Time in Quick Programming mode.

 

TIMER DISPLAY LOCK-OUT

CYCLE COUNTER DISPLAY LOCK-OUT

PTC901: REAL-TIME CLOCK DATE/TIME DISPLAY LOCK-OUT

 

«

 

 

 

«

 

 

«

 

 

«

 

ª

 

 

 

ª

 

 

 

ª

 

 

 

ª

 

 

 

These displays can be programmed for

or

. When a particular meter

function is not used, the Display Lock-out should be set to

for that display.

PROGRAM LOCK-OUT PARAMETERS (VALUE ACCESS)

“Full” Programming Mode permits all parameters to be viewed and modified. This programming mode can be locked with a Security Code and/or a User Input. When locked, and the PAR key is pressed, the meter enters a Quick Programming Mode. In this mode, access to Setpoint Values, Timer & Cycle Counter Start/Stop Values, and Time Setting for the Real-Time Clock can be programmed for “Read”, “Enter”, or “Lock” defined as follows:

SELECTION

DISPLAY

DESCRIPTION

 

 

 

Read

 

Visible, not changeable, in Quick Programming Mode

 

 

 

Enter

 

Visible and changeable in Quick Programming Mode

 

 

 

Lock

 

Not visible in Quick Programming Mode

 

 

 

SETPOINT 1 to 4 VALUE ACCESS ** ( = 1 thru 4)

 

 

«

 

 

 

«

 

 

 

 

«

ª

 

 

ª

 

 

ª

 

 

 

 

 

 

 

 

 

 

 

Setpoint Values for SP1 thru SP4 can be programmed for

,

, or

.

 

 

and

are only displayed when they apply to the Setpoint Action

(

 

) programmed for that particular Setpoint. (See Module 6 for details.)

 

 

 

SECURITY CODE

 

«

to

 

 

 

ª

 

 

 

 

 

 

 

 

Entry of a non-zero value will cause the

prompt to appear when trying

to access the “Full” Programming Mode. Access will only be allowed after entering a matching security code or the universal unlock code of . With this lock-out, a User Input would not have to be used for the Program Lock-out function. Note however, the Security Code lock-out is overridden when an User Input, configured for Program Lock-out ( ), is not active (See Chart.)

PROGRAMMING MODE ACCESS

SECURITY

USER INPUT

USER INPUT

MODE WHEN “PAR”

FULL PROGRAMMING

CODE

SELECTION

STATE

KEY IS PRESSED

MODE ACCESS

 

 

 

 

 

0

not

————

Full Programming

Immediate access

 

 

 

 

 

not 0

 

————

Quick Programming

After Quick Programming

not

with correct Security

 

 

 

 

code entry

not 0

 

Active

Quick Programming

After Quick Programming

 

with correct Security

 

 

 

 

code entry

 

 

 

 

 

not 0

 

Not Active

Full Programming

Immediate access

 

 

 

 

 

0

 

Active

Quick Programming

No access

 

 

 

 

 

0

 

Not Active

Full Programming

Immediate access

 

 

 

 

 

Throughout this bulletin, Programming Mode (without Quick in front) always refers to “Full” Programming.

16

Image 16
Contents User’s Guide Servicing North America Safety Summary General DescriptionTable of Contents General Meter SpecificationsCommunication Cards LDP6-CDC Optional PLUG-IN Cards and AccessoriesSetpoint Cards LDP6-CDS Setting the Jumpers Installing the MeterIndicates factory setting Installing PLUG-IN Cards Wiring the MeterTo Install TOP ViewSinking Logic AC Power DC PowerSourcing Logic Setpoint PLUG-IN Card Terminals Sourcing Output Logic CardSinking Output Logic Card RS232 CommunicationsMeter automatically adjusts the minutes Reviewing the Front Buttons and DisplayTime synchronization between multiple With the HostProgramming the Meter Programming MenuModule 1 Timer Input Parameters Parameter MenuModule 2 User Input and Front Panel Function KEY ParametersRtC-d DspRtC-t SP-1 SP-2SP-3 SP-4Module 3 Display and Program LOCK-OUT Parameters Module 5 Timer Operating Modes Module 4 Cycle Counter ParametersDLYINt INt-LINP OP Module 6 S Etpoint a Larm P Arameters LAtCHOUt « toTimer Stop TIMER/COUNTER Auto ResetOutput Reset with Display Reset Setpoint POWER-UP StateSPNt Module 7 Serial Communications ParametersStrStp Command Chart Command String ConstructionRegister Identification Chart Command String ExamplesAuto/Manual Mode Register MMR ID U Abbreviated TransmissionMeter Response Examples Setpoint Output Register SOR IDSET Time SET Date Module 8 REAL-TIME Clock ParametersSET DAY 12-59p +B/Module 9 Factory Service Operations Restore Factory DefaultsProblem Remedies Press DSP key to return to the Display ModeSp0f-2 Sp0f-3Sp0f-4 USEr-2SP-1 SP-2 SP-3 SP-4 ASM-nACt-n OUt-nPTC900/PTC901 Programming Quick Overview Accessories Part Number InformationWARRANTY/DISCLAIMER Shop online at omega.com

PTC900 specifications

The Omega Vehicle Security PTC900 is a sophisticated vehicle security system designed to provide comprehensive protection against theft and unauthorized access. This cutting-edge technology integrates advanced features and a robust design to ensure peace of mind for vehicle owners.

One of the standout characteristics of the PTC900 is its state-of-the-art immobilizer technology. The system incorporates a unique electronic key code that prevents the engine from starting unless the authorized key is present. This feature significantly deters potential thieves, making it exceedingly difficult to operate the vehicle without the proper authorization.

The PTC900 is equipped with a dual-stage shock sensor that detects both minor and significant impacts. When a disturbance is detected, the system emits a loud alarm, drawing attention and potentially scaring off intruders. This sensor capability allows for a tailored response to various threats, enhancing security without unnecessary disruptions from harmless movements.

Additionally, the Omega Vehicle Security system includes a remote keyless entry feature, allowing users to lock and unlock their vehicles from a distance conveniently. This technology not only provides ease of use but also reinforces the security system by eliminating the need for traditional keys that can be copied or misused.

Another remarkable aspect of the PTC900 is its user-friendly interface. The intuitive control panel enables quick adjustments and customizations to various security settings, allowing users to tailor the system to their specific needs. With clear indicators for system status, users can easily monitor their vehicle’s security at a glance.

The reliability of the Omega Vehicle Security system is further enhanced by its weather-resistant construction, ensuring durability under various environmental conditions. The compact design allows for seamless integration into different vehicle types without compromising aesthetics or functionality.

For those seeking enhanced peace of mind, the PTC900 also offers optional GPS tracking capabilities. This feature enables vehicle owners to monitor their vehicle's location in real time, providing an additional layer of security against theft. If the vehicle is stolen, owners can quickly share location data with law enforcement, increasing the likelihood of recovery.

In conclusion, the Omega Vehicle Security PTC900 stands out as a premium solution in vehicle protection. With its advanced immobilizer technology, dual-stage shock sensor, remote keyless entry, user-friendly features, and optional GPS tracking, it provides comprehensive security, ensuring that vehicle owners can enjoy their investments without fear.