Omega Vehicle Security manual PTC900/PTC901 Programming Quick Overview

Page 29

Real-Time Clock parameters apply to the PTC901 only.

F1/F2 Keys

PAR

Timer Range

Timer Input

Timer Input

Timing

Timer Start

Timer Stop

Flash Timer

Timer Input

Timer Reset

 

Operation

Filtering

Direction

Value

Value

Annunciator

State at

at Power-up

 

 

 

 

 

 

 

Power-up

 

PAR

 

 

 

 

 

USER INPUTS

 

 

 

FUNCTION KEYS

 

 

 

 

 

 

 

PAR

Timer Display

Cycle Counter

 

Real-Time Clock

 

Real-Time Clock

 

Setpoint On

 

Setpoint Off

 

Setpoint

 

Timer Start

Lock-out

Display

 

Date Display

 

Time Display

 

Value Access

 

Value Access

 

Time-Out

 

Value Access

 

Lock-out

 

Lock-out

 

Lock-out

 

 

 

 

 

 

 

 

 

Value Access

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timer Stop

Cycle Counter

 

Cycle Counter

 

RTC Time

 

Security

Value Access

Start Value

 

Stop Value

 

Set Access

 

Code

 

Access

 

Access

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAR

Cycle Counter

 

Cycle Counter

 

Cycle Counter

 

Cycle Counter

 

Cycle Counter

Count Source

 

Count DIrection

 

Start Value

 

Stop Value

 

Reset at Power-up

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setpoint 1

 

Setpoint 1

 

 

 

 

 

 

Predefined Timer

 

 

 

Setpoint 1 Time-

 

 

 

 

 

 

Operating Mode

 

On Value

 

Off Value

 

 

out Value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAR

Setpoint

Setpoint

 

 

Setpoint

 

 

Output

 

Setpoint

 

Setpoint Off

 

Time-out

 

Daily On

Select

Assignment

 

 

Action

 

 

Logic

 

 

On

 

 

 

 

 

 

Value

 

Occurrence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Daily Off

Timer Stop

Timer/Counter

Output Reset

Setpoint

Power-up

Occurrence

 

Auto Reset

w/Display

Annunciator

State

 

 

 

Reset

 

 

PAR

PTC900/PTC901 PROGRAMMING QUICK OVERVIEW

Baud Rate

PAR

Set Time

PAR

Display

Intensity

Level

 

Data Bit

 

 

Parity Bit

 

Meter

Abbreviated

Real-Time Clock

 

Print

 

 

 

 

 

 

 

Address

 

Printing

Print Formatting

 

Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set Date

 

 

Set Day

 

Time Display

 

Date Display

 

Auto Change

 

 

Meter Type

 

Calibrate

 

 

 

 

 

 

Format

 

Format

 

for Daylight

 

for Clock

Real-Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Savings Time

Synchronization

Clock

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

= Setpoint number

 

Factory Service

 

 

Code

 

 

Image 29
Contents User’s Guide Servicing North America General Description Safety SummaryGeneral Meter Specifications Table of ContentsSetpoint Cards LDP6-CDS Optional PLUG-IN Cards and AccessoriesCommunication Cards LDP6-CDC Indicates factory setting Installing the MeterSetting the Jumpers Wiring the Meter Installing PLUG-IN CardsTo Install TOP ViewSourcing Logic AC Power DC PowerSinking Logic Sourcing Output Logic Card Setpoint PLUG-IN Card TerminalsSinking Output Logic Card RS232 CommunicationsReviewing the Front Buttons and Display Meter automatically adjusts the minutesTime synchronization between multiple With the HostProgramming Menu Programming the MeterParameter Menu Module 1 Timer Input ParametersParameters Module 2 User Input and Front Panel Function KEYRtC-t DspRtC-d SP-2 SP-1SP-3 SP-4Module 3 Display and Program LOCK-OUT Parameters Module 4 Cycle Counter Parameters Module 5 Timer Operating ModesDLYINt INt-LINP OP LAtCH Module 6 S Etpoint a Larm P ArametersOUt « toTIMER/COUNTER Auto Reset Timer StopOutput Reset with Display Reset Setpoint POWER-UP StateStrStp Module 7 Serial Communications ParametersSPNt Command String Construction Command ChartRegister Identification Chart Command String ExamplesAbbreviated Transmission Auto/Manual Mode Register MMR ID UMeter Response Examples Setpoint Output Register SOR IDSET DAY Module 8 REAL-TIME Clock ParametersSET Time SET Date +B/ 12-59pRestore Factory Defaults Module 9 Factory Service OperationsProblem Remedies Press DSP key to return to the Display ModeSp0f-3 Sp0f-2Sp0f-4 USEr-2ASM-n SP-1 SP-2 SP-3 SP-4ACt-n OUt-nPTC900/PTC901 Programming Quick Overview Part Number Information AccessoriesWARRANTY/DISCLAIMER Shop online at omega.com

PTC900 specifications

The Omega Vehicle Security PTC900 is a sophisticated vehicle security system designed to provide comprehensive protection against theft and unauthorized access. This cutting-edge technology integrates advanced features and a robust design to ensure peace of mind for vehicle owners.

One of the standout characteristics of the PTC900 is its state-of-the-art immobilizer technology. The system incorporates a unique electronic key code that prevents the engine from starting unless the authorized key is present. This feature significantly deters potential thieves, making it exceedingly difficult to operate the vehicle without the proper authorization.

The PTC900 is equipped with a dual-stage shock sensor that detects both minor and significant impacts. When a disturbance is detected, the system emits a loud alarm, drawing attention and potentially scaring off intruders. This sensor capability allows for a tailored response to various threats, enhancing security without unnecessary disruptions from harmless movements.

Additionally, the Omega Vehicle Security system includes a remote keyless entry feature, allowing users to lock and unlock their vehicles from a distance conveniently. This technology not only provides ease of use but also reinforces the security system by eliminating the need for traditional keys that can be copied or misused.

Another remarkable aspect of the PTC900 is its user-friendly interface. The intuitive control panel enables quick adjustments and customizations to various security settings, allowing users to tailor the system to their specific needs. With clear indicators for system status, users can easily monitor their vehicle’s security at a glance.

The reliability of the Omega Vehicle Security system is further enhanced by its weather-resistant construction, ensuring durability under various environmental conditions. The compact design allows for seamless integration into different vehicle types without compromising aesthetics or functionality.

For those seeking enhanced peace of mind, the PTC900 also offers optional GPS tracking capabilities. This feature enables vehicle owners to monitor their vehicle's location in real time, providing an additional layer of security against theft. If the vehicle is stolen, owners can quickly share location data with law enforcement, increasing the likelihood of recovery.

In conclusion, the Omega Vehicle Security PTC900 stands out as a premium solution in vehicle protection. With its advanced immobilizer technology, dual-stage shock sensor, remote keyless entry, user-friendly features, and optional GPS tracking, it provides comprehensive security, ensuring that vehicle owners can enjoy their investments without fear.