Omega Vehicle Security PTC900 manual TIME-OUT Value, Timer Stop, PTC901 Daily on Occurrence

Page 20

TIME-OUT VALUE

 

«

 

to

 

ª

 

 

 

 

 

 

 

 

 

 

The Time-Out Value only appears when the Setpoint Action (

) is

programmed for Timed Output mode (

). In this mode, the Time-Out Value

is the Setpoint Output time duration, from activation to deactivation. This value is always entered in minutes, seconds, and hundredths of seconds format. The maximum Time-Out Value is 99 minutes 59.99 seconds.

TIMER STOP

«

ª

Timer stops when the Setpoint output activates (

) or deactivates (

).

Select

if the output should not affect the Timer Run/Stop status.

 

Stopping the Timer as a result of this parameter does not constitute a condition (event) for the Setpoint On or Setpoint Off parameters.

PTC901: DAILY ON OCCURRENCE

 

«

 

 

 

 

 

ª

 

 

 

 

 

 

This parameter only appears when the Setpoint is assigned (

) to the

Real-Time Clock Time display (

). This parameter determines the days of

the week when the Setpoint output will activate.

 

 

Selecting

displays a sublist for choosing the days of the week. On all

days entered as

in the sublist, the output will activate. On all days entered

as , the output will not activate. The output activation is repetitive, and will

occur every week on the chosen day(s).

 

 

 

DISPLAY

DESCRIPTION

FACTORY

 

 

 

 

 

Sunday

 

 

 

 

 

 

Monday

 

 

 

 

 

 

Tuesday

 

 

 

 

 

 

Wednesday

 

 

 

 

 

 

Thursday

 

 

 

 

 

 

Friday

 

 

 

 

 

 

Saturday

 

 

Setpoint One-Shot Mode

 

 

 

If all days are set to

, the Setpoint will operate in “One-shot” mode. When

a One-shot setpoint is enabled (armed), the setpoint output will activate at the

set time and disable itself from activating again. To enable or re-enable a one-

shot alarm, go to the Setpoint value entry display and press the Up or Dn key

repeatedly while the AM/PM digit is selected (flashing). When the 2nd digit

decimal point is lit, the Setpoint is enabled. The Setpoint enable status is saved

at power-down. The enable state of the Setpoint is not affected or changed when

the Parameter List is exchanged.

 

 

 

The setpoint will turn off (de-activate) as programmed per the Setpoint

Action selected. If

 

mode is selected, program all the Daily Off days to

to have the Setpoint turn off at the next Daily Off Occurrence. The One-

shot status can also be viewed or set from the Setpoint Off value entry display.

PTC901: DAILY OFF OCCURRENCE

 

«

 

 

 

 

ª

 

 

 

 

 

This parameter only appears when the Setpoint is assigned (

) to the

Real-Time Clock Time display (

) and when the Setpoint Action (

)

is programmed for On-Off Output mode (

). In this mode, this parameter

determines the days of the week when the Setpoint output will deactivate.

 

Selecting

displays a sublist for choosing the days of the week. On all

days entered as

in the sublist, the output will deactivate. On all days entered

as , the output will not deactivate. The output deactivation is repetitive, and

will occur every week on the chosen day(s).

 

 

 

 

DISPLAY

DESCRIPTION

FACTORY

 

 

Sunday

Monday

Tuesday

Wednesday

Thursday

Friday

Saturday

TIMER/COUNTER AUTO RESET

«

ª

When the Setpoint output activates (

) or deactivates (

), the meter

automatically resets the Setpoint Assignment display (

). Select

if the

Setpoint output should not cause the assigned display to reset. Does not apply to manual activations or deactivations by user input, function key, or serial communications.

OUTPUT RESET WITH DISPLAY RESET

«

ª

When

is selected,

the Setpoint output will reset when the Setpoint

Assignment display (

) resets. Select

if the Setpoint output should not

reset when the assigned display resets.

 

SETPOINT ANNUNCIATOR

«

ª

This parameter controls the illumination of the LED annunciator for the corresponding Setpoint output ( ) as follows:

Normal (

)

Annunciator displayed when output is “on” (activated)

Reverse (

)

Annunciator displayed when output is “off” (deactivated)

Flash (

 

)

Annunciator and display flashes when output is “on” (activated)

Off (

)

 

Annunciator disabled

 

 

 

SETPOINT POWER-UP STATE

« ª

Determines the on/off state of the Setpoint output at power-up. Regardless of output logic setting (normal or reverse).

Deactivates the Setpoint output at power-up

Activates the Setpoint output at power-up

Restores the output to the state it was in prior to power-down

20

Image 20
Contents User’s Guide Servicing North America Safety Summary General DescriptionTable of Contents General Meter SpecificationsSetpoint Cards LDP6-CDS Optional PLUG-IN Cards and AccessoriesCommunication Cards LDP6-CDC Indicates factory setting Installing the MeterSetting the Jumpers Installing PLUG-IN Cards Wiring the MeterTo Install TOP ViewSourcing Logic AC Power DC PowerSinking Logic Setpoint PLUG-IN Card Terminals Sourcing Output Logic CardSinking Output Logic Card RS232 CommunicationsMeter automatically adjusts the minutes Reviewing the Front Buttons and DisplayTime synchronization between multiple With the HostProgramming the Meter Programming MenuModule 1 Timer Input Parameters Parameter MenuModule 2 User Input and Front Panel Function KEY ParametersRtC-t DspRtC-d SP-1 SP-2SP-3 SP-4Module 3 Display and Program LOCK-OUT Parameters Module 5 Timer Operating Modes Module 4 Cycle Counter ParametersDLYINt INt-LINP OP Module 6 S Etpoint a Larm P Arameters LAtCHOUt « toTimer Stop TIMER/COUNTER Auto ResetOutput Reset with Display Reset Setpoint POWER-UP StateStrStp Module 7 Serial Communications ParametersSPNt Command Chart Command String ConstructionRegister Identification Chart Command String ExamplesAuto/Manual Mode Register MMR ID U Abbreviated TransmissionMeter Response Examples Setpoint Output Register SOR IDSET DAY Module 8 REAL-TIME Clock ParametersSET Time SET Date 12-59p +B/Module 9 Factory Service Operations Restore Factory DefaultsProblem Remedies Press DSP key to return to the Display ModeSp0f-2 Sp0f-3Sp0f-4 USEr-2SP-1 SP-2 SP-3 SP-4 ASM-nACt-n OUt-nPTC900/PTC901 Programming Quick Overview Accessories Part Number InformationWARRANTY/DISCLAIMER Shop online at omega.com

PTC900 specifications

The Omega Vehicle Security PTC900 is a sophisticated vehicle security system designed to provide comprehensive protection against theft and unauthorized access. This cutting-edge technology integrates advanced features and a robust design to ensure peace of mind for vehicle owners.

One of the standout characteristics of the PTC900 is its state-of-the-art immobilizer technology. The system incorporates a unique electronic key code that prevents the engine from starting unless the authorized key is present. This feature significantly deters potential thieves, making it exceedingly difficult to operate the vehicle without the proper authorization.

The PTC900 is equipped with a dual-stage shock sensor that detects both minor and significant impacts. When a disturbance is detected, the system emits a loud alarm, drawing attention and potentially scaring off intruders. This sensor capability allows for a tailored response to various threats, enhancing security without unnecessary disruptions from harmless movements.

Additionally, the Omega Vehicle Security system includes a remote keyless entry feature, allowing users to lock and unlock their vehicles from a distance conveniently. This technology not only provides ease of use but also reinforces the security system by eliminating the need for traditional keys that can be copied or misused.

Another remarkable aspect of the PTC900 is its user-friendly interface. The intuitive control panel enables quick adjustments and customizations to various security settings, allowing users to tailor the system to their specific needs. With clear indicators for system status, users can easily monitor their vehicle’s security at a glance.

The reliability of the Omega Vehicle Security system is further enhanced by its weather-resistant construction, ensuring durability under various environmental conditions. The compact design allows for seamless integration into different vehicle types without compromising aesthetics or functionality.

For those seeking enhanced peace of mind, the PTC900 also offers optional GPS tracking capabilities. This feature enables vehicle owners to monitor their vehicle's location in real time, providing an additional layer of security against theft. If the vehicle is stolen, owners can quickly share location data with law enforcement, increasing the likelihood of recovery.

In conclusion, the Omega Vehicle Security PTC900 stands out as a premium solution in vehicle protection. With its advanced immobilizer technology, dual-stage shock sensor, remote keyless entry, user-friendly features, and optional GPS tracking, it provides comprehensive security, ensuring that vehicle owners can enjoy their investments without fear.