Omega Vehicle Security PTC900 manual Inp Op

Page 18

Timing Diagrams for Predefined Timer Operating Modes

NOTE: Input A is shown as a Sourcing input (active high). If a Sinking input (active low) is used, the logic levels for Input A would be inverted.

On-Delay Timing

On-Delay / Interval Timing

Input A

 

 

 

 

Input A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

 

 

 

T

 

 

T1

 

T2

 

 

 

 

T

 

 

 

 

 

 

 

Output 1

 

 

 

 

Output 1

 

 

 

 

 

 

 

Off-Delay Timing

Input A

T T

Output 1

Interval Timing (Level triggered)

Input A

T T

Output 1

The input signal must be wired to both the Input A and User Input 1 terminals. The Timer Input plug jumper and the User Input plug jumper must both be set to the same position (either both SNK or both SRC).

The input signal must be wired to both the Input A and User Input 1 terminals. The Timer Input plug jumper and the User Input plug jumper must be set to opposite positions (one SNK, one SRC) and the Input signal must be a current sinking type (i.e. pulls input to common).

Repeat Cycle Timing

Input A

 

 

 

 

 

 

 

 

 

T1

 

T2

T1

 

 

 

 

 

T

 

 

 

 

 

 

 

 

 

Output 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interval Timing (Edge triggered)

Input A

 

T

T

Output 1

Parameter Settings for Predefined Timer Operating Modes

MODULE 1 - Timer Input Parameters (

)

DISPLAY

PARAMETER

INP OP

Timer Input Operation

ON-dLY

OF-dLY

rEPEAt

dLYINt

INt-L

INt-E

EdrS-2

EdrS-2

EdrS-2

EdrS-2

LEVrSt

EdrS-2

MODULE 2 - User Input Parameters ( )

DISPLAY

PARAMETER

ON-dLY

OF-dLY

rEPEAt

dLYINt

INt-L

INt-E

USEr-1

User Input 1

 

N/A

rSt-L

N/A

N/A

OrSt-E

N/A

rSt

Reset Key

 

NO

NO

NO

NO

(SP1-YES)

NO

 

 

 

 

 

 

 

NO

 

MODULE 6 - Setpoint Parameters (

)

 

 

 

 

 

DISPLAY

PARAMETER

ON-dLY

OF-dLY

rEPEAt

dLYINt

INt-L

INt-E

SPSEL

Setpoint Select

 

SP-1

SP-1

SP-1

SP-1

SP-1

SP-1

ASN-1

Setpoint Assignment

t-dSP

t-dSP

t-dSP

t-dSP

t-dSP

t-dSP

ACt-1

Setpoint Action

LAtCH

ON-OFF

ON-OFF

t-OUt

ON-OFF

t-OUt

OUt-1

Output Logic

 

NOr

NOr

NOr

NOr

NOr

NOr

ON-1

Setpoint On

VALUE

t-Strt

VALUE

VALUE

t-Strt

t-Strt

SP-1

Setpoint On Value

 

T*

N/A

T1*

T1*

N/A

N/A

OFf-1

Setpoint Off

 

N/A

VALUE

VALUE

N/A

VALUE

N/A

SPOf-1

Setpoint Off Value

 

N/A

T*

T2*

N/A

T*

N/A

tOUt-1

Time-out Value

 

N/A

N/A

N/A

T2*

N/A

T*

tstP-1

Timer Stop

 

NO

0-OFF

NO

0-OFF

0-OFF

0-OFF

AUtO-1

Timer/Counter Auto Reset

 

NO

NO

0-OFF

NO

NO

NO

OrSd-1

Output Reset w/display Reset

 

NO

NO

NO

NO

NO

NO

Lit-1

Setpoint Annunciator

 

NOr

NOr

NOr

NOr

NOr

NOr

P-UP-1

Power-up State

 

OFF

OFF

OFF

OFF

OFF

OFF

* Refer to timing diagrams. These parameters are the actual Setpoint On/Off or Time-Out values set by the user for the specific application.

18

Image 18
Contents User’s Guide Servicing North America Safety Summary General DescriptionTable of Contents General Meter SpecificationsOptional PLUG-IN Cards and Accessories Communication Cards LDP6-CDCSetpoint Cards LDP6-CDS Installing the Meter Setting the JumpersIndicates factory setting To Install Installing PLUG-IN CardsWiring the Meter TOP ViewAC Power DC Power Sinking LogicSourcing Logic Sinking Output Logic Card Setpoint PLUG-IN Card TerminalsSourcing Output Logic Card RS232 CommunicationsTime synchronization between multiple Meter automatically adjusts the minutesReviewing the Front Buttons and Display With the HostProgramming the Meter Programming MenuModule 1 Timer Input Parameters Parameter MenuModule 2 User Input and Front Panel Function KEY ParametersDsp RtC-dRtC-t SP-3 SP-1SP-2 SP-4Module 3 Display and Program LOCK-OUT Parameters DLYINt Module 5 Timer Operating ModesModule 4 Cycle Counter Parameters INt-LINP OP OUt Module 6 S Etpoint a Larm P ArametersLAtCH « toOutput Reset with Display Reset Timer StopTIMER/COUNTER Auto Reset Setpoint POWER-UP StateModule 7 Serial Communications Parameters SPNtStrStp Register Identification Chart Command ChartCommand String Construction Command String ExamplesMeter Response Examples Auto/Manual Mode Register MMR ID UAbbreviated Transmission Setpoint Output Register SOR IDModule 8 REAL-TIME Clock Parameters SET Time SET DateSET DAY 12-59p +B/Problem Remedies Module 9 Factory Service OperationsRestore Factory Defaults Press DSP key to return to the Display ModeSp0f-4 Sp0f-2Sp0f-3 USEr-2ACt-n SP-1 SP-2 SP-3 SP-4ASM-n OUt-nPTC900/PTC901 Programming Quick Overview Accessories Part Number InformationWARRANTY/DISCLAIMER Shop online at omega.com

PTC900 specifications

The Omega Vehicle Security PTC900 is a sophisticated vehicle security system designed to provide comprehensive protection against theft and unauthorized access. This cutting-edge technology integrates advanced features and a robust design to ensure peace of mind for vehicle owners.

One of the standout characteristics of the PTC900 is its state-of-the-art immobilizer technology. The system incorporates a unique electronic key code that prevents the engine from starting unless the authorized key is present. This feature significantly deters potential thieves, making it exceedingly difficult to operate the vehicle without the proper authorization.

The PTC900 is equipped with a dual-stage shock sensor that detects both minor and significant impacts. When a disturbance is detected, the system emits a loud alarm, drawing attention and potentially scaring off intruders. This sensor capability allows for a tailored response to various threats, enhancing security without unnecessary disruptions from harmless movements.

Additionally, the Omega Vehicle Security system includes a remote keyless entry feature, allowing users to lock and unlock their vehicles from a distance conveniently. This technology not only provides ease of use but also reinforces the security system by eliminating the need for traditional keys that can be copied or misused.

Another remarkable aspect of the PTC900 is its user-friendly interface. The intuitive control panel enables quick adjustments and customizations to various security settings, allowing users to tailor the system to their specific needs. With clear indicators for system status, users can easily monitor their vehicle’s security at a glance.

The reliability of the Omega Vehicle Security system is further enhanced by its weather-resistant construction, ensuring durability under various environmental conditions. The compact design allows for seamless integration into different vehicle types without compromising aesthetics or functionality.

For those seeking enhanced peace of mind, the PTC900 also offers optional GPS tracking capabilities. This feature enables vehicle owners to monitor their vehicle's location in real time, providing an additional layer of security against theft. If the vehicle is stolen, owners can quickly share location data with law enforcement, increasing the likelihood of recovery.

In conclusion, the Omega Vehicle Security PTC900 stands out as a premium solution in vehicle protection. With its advanced immobilizer technology, dual-stage shock sensor, remote keyless entry, user-friendly features, and optional GPS tracking, it provides comprehensive security, ensuring that vehicle owners can enjoy their investments without fear.