Multi-Tech Systems Hub manual Compliance with BS6789 .1 and Part, Compliance with BS6328 Part

Page 39

Appendices

Compliance with BS6305 Clause 6.2, BS6320 Clause 7.2, and BABT/ SITS/82/005S/D

a.The modem is suitable for connection to the Public Switched Telephone Network (PSTN) provided by British Telecommunications plc or Kingston Communications (Hull) plc. Circuit supply by British Communications, Mercury Communication, or Hull City Council. Only direct exchange lines may be used, not shared service.

b.The modem is suitable for household, office, and similar general indoor use. It is not suitable for use as an extension to a payphone.

c.BT lines supplied must support either loop disconnect or multifrequency tone signalling.

d.REN (Ringer Equivalence Number).

The REN value of a unit is calculated from 3/n where n is the total number of units which can be connected in parallel which will still cause the standard bell (as defined in BS6305 Appendix D) to ring.

REN values of less than 0.3 cannot be assigned.

REN = 1

If a telephone or other device is connected in parallel with the modem, the combined REN

must not exceed 4. A BT supplied telephone may be assumed to have REN of 1.0 unless otherwise noted.

The approval of this modem for connection to the British Telecom public switched telephone network is INVALIDATED if the apparatus is subject to any modification in any material way not authorized by BABT or if it is used with or connected to:

i.internal software that has not been formally accepted BABT.

ii.external control software or external control apparatus which cause the operation of the modem associated call set-up equipment to contravene the requirements of the standard set out in BABT/SITS/82/005S/D.

All other apparatus connected to this modem and thereby connected directly or indirectly to the British Telecom public switched telephone network must be approved apparatus as defined in Section 22 of the British Telecommunications Act 1984.

Compliance with BS6789: Section 3.1 and Part 2

a.The modem is not capable of allowing Auto Call using '999' or other PABX emergency numbers.

b.Modes other than modes 1, 2, or 3 should not be used on the BT PSTN. This modem

is a mode 1 device.

c.Users are advised to check the numbers entered during the Auto Call set up phase prior to dialing.

d.The user should not issue any sequence of commands to the modem which would cause the modem to exceed the maximum allowable pause of 8 seconds from the time the modem goes off hook until dialing begins.

e.For correct operation of the call progress monitor, the power has to be properly connected and switched on.

Compliance with BS6328 Part 1

a.The modem is not suitable for use on circuits with British Telecommunications signaling at a normal frequency of 2280 Hz.

b.The modem does not require signaling or otherwise employ the frequency range dc to 200 Hz.

c.The modem does not require dc from the Private Circuit for correct operation. The modem may be damaged if connected, in a private circuit mode, to a circuit supplying dc current (the maximum permissible direct current is zero amps).

CommPlete 4000 Communications Server User Guide

39

Image 39
Contents User Guide Patents Record of RevisionsContents Appendices Product Overview System OverviewRASExpress Documentation Set OverviewChassis Technical SpecificationsPower Supply DimensionsCable Connections Safety WarningsUnpacking Rack MountingSBC Board SBC Board CablingShared Interrupt For Top Slots Identical Devices Required ISI Board CablingSerial Card Upgrades Power Supply Connectors Powering UpWhat you need to start Accessing RASExpressA8. Type the IP Subnet Mask CommPlete 4000 Communications Server User Guide B8. Type the IP Subnet Mask Using Dial-In Access Disconnecting Cables and Removal from Enclosure Hardware removal/ReplacementCover Mounting Screws Card Cage Removal/ReplacementRed Red Orange RedRed White Removing SBC Board Board Removal and ReplacementRemoving ISI Boards Hard Disk Drive Removal/ReplacementCdrom Removal/Replacement Floppy Disk Drive Removal/ReplacementPower Supply Removal/Replacement COM1, COM2, or LPT1 port does not respond correctly TroubleshootingSBC does not boot correctly or hangs after video appears No VideoDiagnostic Tests Invalid Time, Date or SetupKeyboard does not respond to key strokes Addendum for North American Products Limited WarrantyRecording CommPlete 4000 Information Out of Warranty Repair Costs On-line Warranty RegistrationTechnical Support Addendum for International ProductsOrdering Accessories ServiceContacting Technical Support Appendix A-Back Panel Connector Pinouts VGA 15-Pin ConnectorPinDescription Pin DB9 COM 1 Connector Pin Circular JackPin Description Pin Floppy Disk Drive Connector RJ-45 ConnectorPrinter Port Connector COM 2 Port ConnectorPinSignal Name Direction IOCS16 Hard Disk ConnectorAppendices FCC Part 15 Regulation Canadian Limitations NoticeIndustry Canada Compliance with Babt Requirements European Low Voltage Directive Example Diagram Showing Creepage Clearance DistancesCompliance with BS6328 Part Compliance with BS6789 .1 and PartEMC, Safety, and Terminal Directive Compliance