COMMAND MODE OPTIONS

The following LCDs are used to configure result code responses.

ENABLE/DISABLE RESPONSE

Use the Æ and Enter buttons to enable or disable the sending of result codes to the computer. Same as the Q0 and Q1 commands.

VERBOSE/TERSE RESPONSE

Use the Æ and Enter buttons to select verbose or terse result codes. Same as the V0 and V1 commands.

ENABLE/DISABLE CMD MODE

Use the Æ and Enter buttons to enable or disable the modem’s ability to accept AT commands.

SYNC/ASYNC OPTIONS

Use the Æ and Enter buttons to select the method of data transmission.

ASYNC, NORM?

Normal asynchronous transmission using the AT command set.

ASYNC, V.25bis?

Asynchronous transmission using the V.25bis command set.

SYNC, NORM?

Normal synchronous transmission using any command set.

V.25bis HDLC NRZ?

V.25bis synchronous transmission using NRZ encoding.

V.25bis HDLC NRZI?

V.25bis synchronous transmission using NRZI encoding.

V.25bis BISYNC?

V.25bis bisynchronous transmission.

RESET FACTORY DEFAULTS

Use the Æ and Enter buttons to reset Profile 0 and the modem’s active configuration to the factory defaults. Same as the AT&F&W command string.

CONNECT RATE OPTIONS

Use the Æ and Enter buttons to change the modem’s serial port and data transmission speeds.

SERIAL BAUD RATE

Use the Æ and Enter buttons to select the modem’s serial port speed. The valid range is 1200 to 115200 bps. Same as the $SB commands.

MODEM SPEED

Use the Æ and Enter buttons to select the modulation protocol to use in originating or answering a connection. This also selects the maximum transmission speed at which the modem can operate. Same as the +MS=[mod] - command.

Multi-Tech Systems, Inc. MT5600BA-V92 User Guide

24

Image 24
Contents MultiModem Revision Date Description Table of Contents Product Description Features FeaturesProduct Description Safety Warnings About AT CommandsTechnical Specifications Modem CompatibilityOperating Temperature Installation Two-Wire or Four-Wire Leased Line ConnectionConnect the Modem to Your System Connect the Modem to Your PCInstall the Modem Driver Connect the Modem to the AC Power OutletPower-On Test Installing the Modem DriverSetting Your Country or Region Code Using the LCD Panel Country or Region CodesUsing the Global Wizard Using AT CommandsInstall PhoneTools Using the Front Panel Modem ConfigurationLED Indicators Liquid Crystal Display LCD Option SelectionStatus Trunk Basic Options Trunk Basic Options Trunk Advanced Options Trunk Advanced Options Trunk Remote Configuration Options Trunk Diagnostic Options TrunkPhone Number Memory Options Trunk Caller ID Options TrunkSetting Country/Region Codes Trunk Caller ID Region SelectFunctionality of Menu Options StatusBasic Options Online OptionsCommand Mode Options Advanced Options RS232 OptionsCallback Security Remote Configuration Options Diagnostic OptionsPhone Number Memory Options Caller ID Options Region Select OptionsTwo-Wire / Four-Wire Setup Leased Line OperationFour-Wire Setup Dial BackupDial Backup and Leased Line Restore Setup Remote Configuration Basic ProcedureSetup Changing the Remote Configuration Password Changing the Remote Escape Character Setup Procedures Callback SecurityTurning Callback Security On and Off Assigning Callback Passwords Front Panel MethodAssigning Callback Phone Numbers Calling Procedure Callback Security Commands Default DescriptionTroubleshooting None of the Indicators LightModem Does Not Respond to Commands Modem Cannot Connect When DialingModem Cannot Connect When Answering Modem Disconnects While OnlineFile Transfer Is Slower Than It Should Be Data Is Being LostThere Are Garbage Characters on the Monitor Modem Doesn’t Work with Caller IDAppendix a Regulatory Compliance FCC Part 68 TelecomEMC, Safety, and R&TTE Directive Compliance Canadian Limitations NoticeInternational Modem Restrictions New Zealand Telecom Warning Notice South African NoticeUpgrade Overview Appendix B Upgrading FirmwareIntroduction Identify the Modem FirmwareDownload the Upgrade File Extract the Upgrade FilesUpgrade the Modem’s Firmware Clear Your Stored ParametersRestore Your Parameters Appendix C Installing a Modem Under Linux InstallationUsing the Modem to Call the Internet Standard Linux Serial Port DefinitionsCalling the ISP Answering CallsAppendix D Pin Descriptions RS-232 Pin DescriptionsRS-232 Cable Pinouts Leased Line PinoutsWeee Directive Appendix F Rohs HT/TS Substance Concentration Index #DBRegisters

PN S000408C specifications

The Multi-Tech Systems PN S000408C is a versatile and compact communication device designed for a wide range of applications in various industries. This device is primarily known for its robust performance, making it an ideal choice for developing Internet of Things (IoT) solutions, machine-to-machine (M2M) communications, and other telemetry applications.

One of the main features of the S000408C is its ability to support multiple communication protocols, which enhances its flexibility and interoperability with different systems. This device can seamlessly integrate with cellular, Ethernet, and serial interfaces, providing users the capability to implement diverse connectivity solutions. Its versatility enables it to function effectively in remote monitoring, data logging, and industrial automation scenarios.

The S000408C is engineered to work with multiple wireless technologies, including LTE, GSM, and CDMA, ensuring reliable connectivity across various geographical locations. This feature is essential for applications where consistent communication is necessary, such as in asset tracking and fleet management. Additionally, the device is compatible with various network configurations, making it suitable for both urban and remote deployments.

In terms of characteristics, the device stands out with its compact design, which allows for easy installation even in space-constrained environments. It features a rugged enclosure that is built to withstand harsh conditions, making it ideal for outdoor use. The S000408C is also equipped with power management capabilities, allowing for energy-efficient operation, which is crucial for battery-powered applications.

Moreover, the Multi-Tech S000408C prioritizes security, as it comes with built-in encryption features to protect data integrity during transmission. This aspect is particularly important for industries dealing with sensitive information, such as healthcare and finance.

The configuration process of the S000408C is straightforward, supported by comprehensive documentation and user-friendly software tools. This makes it accessible to developers and engineers, enabling them to rapidly deploy solutions without extensive training.

In conclusion, the Multi-Tech Systems PN S000408C is a powerful tool for businesses and developers aiming to harness the power of connectivity in their operations. With its multi-protocol support, robustness, and security features, it is well-positioned to meet the demands of today's connected world. As industries continue to evolve with the integration of IoT technologies, devices like the S000408C will remain at the forefront of enabling communication and operational efficiency.