Multi-Tech Systems PN S000408C manual Calling Procedure

Page 37

Chapter 6 – Callback Security

Calling Procedure

Use the following procedure to call a modem that has callback security enabled. Autoanswer must be enabled on the calling modem (S0=1 or S0=2).

1.Using a data communication program such as HyperTerminal, dial the number of the callback modem.

2.When the connection is established, the callback modem responds with a request for a password.

3.Type the password for your modem, and then press ENTER. You have three attempts to enter a valid password or be disconnected.

4.If the password is valid, the callback modem disconnects. Then, after a short delay, it calls the number associated with the password and establishes a working connection.

Note: If you are calling a direct connect number, you must append a hyphen (-) to the password. If the corresponding phone number has - as its first character, you will be able to go directly online with the callback modem. If the corresponding phone number has no - character, you will be prompted for a different password.

8.Press Æ, Æ to go to the ENTER NUMBER #2? LCD.

9.Repeat steps 3–7 to enter the next number.

10.Repeat as many times as necessary, up to memory location 30, until all numbers have been entered.

Warning: There is no way to review an entry to confirm that it has been entered correctly. If you attempt to look at a number entry by pressing the Enter button for an ENTER NUMBER #n? LCD, it is possible for you to accidentally erase the entry.

Multi-Tech Systems, Inc. MT5600BA-V92 User Guide

37

Image 37
Contents MultiModem Revision Date Description Table of Contents Features Product Description FeaturesProduct Description About AT Commands Safety WarningsModem Compatibility Technical SpecificationsOperating Temperature Two-Wire or Four-Wire Leased Line Connection InstallationConnect the Modem to Your System Connect the Modem to Your PCConnect the Modem to the AC Power Outlet Install the Modem DriverPower-On Test Installing the Modem DriverUsing the LCD Panel Country or Region Codes Setting Your Country or Region CodeUsing AT Commands Using the Global WizardInstall PhoneTools Modem Configuration Using the Front PanelLED Indicators Option Selection Liquid Crystal Display LCDStatus Trunk Basic Options Trunk Basic Options Trunk Advanced Options Trunk Diagnostic Options Trunk Advanced Options Trunk Remote Configuration Options TrunkCaller ID Options Trunk Phone Number Memory Options TrunkCaller ID Region Select Setting Country/Region Codes TrunkStatus Functionality of Menu OptionsOnline Options Basic OptionsCommand Mode Options RS232 Options Advanced OptionsCallback Security Diagnostic Options Remote Configuration OptionsPhone Number Memory Options Region Select Options Caller ID OptionsLeased Line Operation Two-Wire / Four-Wire SetupDial Backup Four-Wire SetupDial Backup and Leased Line Restore Setup Basic Procedure Remote ConfigurationSetup Changing the Remote Configuration Password Changing the Remote Escape Character Callback Security Setup ProceduresTurning Callback Security On and Off Front Panel Method Assigning Callback PasswordsAssigning Callback Phone Numbers Calling Procedure Default Description Callback Security CommandsNone of the Indicators Light TroubleshootingModem Cannot Connect When Dialing Modem Does Not Respond to CommandsModem Disconnects While Online Modem Cannot Connect When AnsweringData Is Being Lost File Transfer Is Slower Than It Should BeThere Are Garbage Characters on the Monitor Modem Doesn’t Work with Caller IDFCC Part 68 Telecom Appendix a Regulatory ComplianceCanadian Limitations Notice EMC, Safety, and R&TTE Directive ComplianceInternational Modem Restrictions South African Notice New Zealand Telecom Warning NoticeAppendix B Upgrading Firmware Upgrade OverviewIntroduction Identify the Modem FirmwareExtract the Upgrade Files Download the Upgrade FileUpgrade the Modem’s Firmware Clear Your Stored ParametersRestore Your Parameters Installation Appendix C Installing a Modem Under LinuxUsing the Modem to Call the Internet Standard Linux Serial Port DefinitionsAnswering Calls Calling the ISPRS-232 Pin Descriptions Appendix D Pin DescriptionsLeased Line Pinouts RS-232 Cable PinoutsWeee Directive Appendix F Rohs HT/TS Substance Concentration #DB IndexRegisters

PN S000408C specifications

The Multi-Tech Systems PN S000408C is a versatile and compact communication device designed for a wide range of applications in various industries. This device is primarily known for its robust performance, making it an ideal choice for developing Internet of Things (IoT) solutions, machine-to-machine (M2M) communications, and other telemetry applications.

One of the main features of the S000408C is its ability to support multiple communication protocols, which enhances its flexibility and interoperability with different systems. This device can seamlessly integrate with cellular, Ethernet, and serial interfaces, providing users the capability to implement diverse connectivity solutions. Its versatility enables it to function effectively in remote monitoring, data logging, and industrial automation scenarios.

The S000408C is engineered to work with multiple wireless technologies, including LTE, GSM, and CDMA, ensuring reliable connectivity across various geographical locations. This feature is essential for applications where consistent communication is necessary, such as in asset tracking and fleet management. Additionally, the device is compatible with various network configurations, making it suitable for both urban and remote deployments.

In terms of characteristics, the device stands out with its compact design, which allows for easy installation even in space-constrained environments. It features a rugged enclosure that is built to withstand harsh conditions, making it ideal for outdoor use. The S000408C is also equipped with power management capabilities, allowing for energy-efficient operation, which is crucial for battery-powered applications.

Moreover, the Multi-Tech S000408C prioritizes security, as it comes with built-in encryption features to protect data integrity during transmission. This aspect is particularly important for industries dealing with sensitive information, such as healthcare and finance.

The configuration process of the S000408C is straightforward, supported by comprehensive documentation and user-friendly software tools. This makes it accessible to developers and engineers, enabling them to rapidly deploy solutions without extensive training.

In conclusion, the Multi-Tech Systems PN S000408C is a powerful tool for businesses and developers aiming to harness the power of connectivity in their operations. With its multi-protocol support, robustness, and security features, it is well-positioned to meet the demands of today's connected world. As industries continue to evolve with the integration of IoT technologies, devices like the S000408C will remain at the forefront of enabling communication and operational efficiency.