Multi-Tech Systems PN S000408C manual Leased Line Operation, Two-Wire / Four-Wire Setup

Page 29

Chapter 4 – Leased Line Operation

Chapter 4 - Leased Line Operation

This chapter describes how to use the MultiModem II modem on a leased line.

A leased line is a private, permanent, telephone connection between two points. Unlike normal dialup connections, a leased line is always active. The modems automatically connect when they are attached to the line and are turned on. Because a leased line is always active, one of the two modems on the line must be configured as the originate modem and the other as the answer modem; it does not matter which is which.

In the event of an interruption, leased line modems automatically reconnect when the data line or power is restored. The modem also supports dial backup, which enables the modem to automatically switch to a dial-up connection if the leased line goes down.

The modem supports both two-wire and four-wire leased-line operation.

Two-Wire / Four-Wire Setup

1.For leased line operation, plug one end of a two-wire phone cable into the modem’s LEASED jack. Connect the other end to a leased line wall jack or terminals.

2.Turn on the modem.

3.Starting at the STATUS LCD, press the following buttons on the front panel: È, Æ, È, È, È, Æ. The CURRENT SETTING= LCD appears.

4.If the CURRENT SETTING= LCD shows ASYNC AT, press ÇÅ and go to step 7. If it shows anything else, press Æ to go to the ASYNC, NORM? LCD.

5.Press the Enter button to select normal asynchronous operation.

6.The OPTION SET LCD appears. Press ÇÅ to exit to the SYNC/ASYNC OPTIONS LCD.

7.Press ÇÅ, ÇÅ, ÇÅ, Æ, Æ, Æ, Æ. The 2 WIRE LEASE? ORIG LCD appears.

8.Choose one of two actions:

To set up the modem as the originate modem, press the Enter button.

To set up the modem as the answer modem, press Æ to display the 2 WIRE LEASE? ANSWER LCD, and then press the Enter button.

Note: One of the modems in a leased line pair must be configured as the originate modem, and the other as the answer modem, but it does not matter which is which.

9.The OPTION SET LCD appears. Press ÇÅ to exit to the ONLINE OPTIONS LCD, or Æ to exit to the CURRENT SETTING= LCD to verify the selection.

10.This completes the setup for two-wire leased line operation. Upon completion, the modem attempts to connect to the modem at the other end of the leased line. If the remote modem has not yet been configured for leased line operation, you may turn off the local modem until the remote one is ready.

Multi-Tech Systems, Inc. MT5600BA-V92 User Guide

29

Image 29
Contents MultiModem Revision Date Description Table of Contents Product Description Product Description FeaturesFeatures About AT Commands Safety WarningsModem Compatibility Technical SpecificationsOperating Temperature Two-Wire or Four-Wire Leased Line Connection InstallationConnect the Modem to Your System Connect the Modem to Your PCConnect the Modem to the AC Power Outlet Install the Modem DriverPower-On Test Installing the Modem DriverUsing the LCD Panel Country or Region Codes Setting Your Country or Region CodeUsing AT Commands Using the Global WizardInstall PhoneTools LED Indicators Using the Front PanelModem Configuration Option Selection Liquid Crystal Display LCDStatus Trunk Basic Options Trunk Basic Options Trunk Advanced Options Trunk Diagnostic Options Trunk Advanced Options Trunk Remote Configuration Options TrunkCaller ID Options Trunk Phone Number Memory Options TrunkCaller ID Region Select Setting Country/Region Codes TrunkStatus Functionality of Menu OptionsOnline Options Basic OptionsCommand Mode Options RS232 Options Advanced OptionsCallback Security Phone Number Memory Options Remote Configuration OptionsDiagnostic Options Region Select Options Caller ID OptionsLeased Line Operation Two-Wire / Four-Wire SetupDial Backup Four-Wire SetupDial Backup and Leased Line Restore Setup Setup Changing the Remote Configuration Password Remote ConfigurationBasic Procedure Changing the Remote Escape Character Turning Callback Security On and Off Setup ProceduresCallback Security Front Panel Method Assigning Callback PasswordsAssigning Callback Phone Numbers Calling Procedure Default Description Callback Security CommandsNone of the Indicators Light TroubleshootingModem Cannot Connect When Dialing Modem Does Not Respond to CommandsModem Disconnects While Online Modem Cannot Connect When AnsweringData Is Being Lost File Transfer Is Slower Than It Should BeThere Are Garbage Characters on the Monitor Modem Doesn’t Work with Caller IDFCC Part 68 Telecom Appendix a Regulatory ComplianceInternational Modem Restrictions EMC, Safety, and R&TTE Directive ComplianceCanadian Limitations Notice South African Notice New Zealand Telecom Warning NoticeAppendix B Upgrading Firmware Upgrade OverviewIntroduction Identify the Modem FirmwareExtract the Upgrade Files Download the Upgrade FileUpgrade the Modem’s Firmware Clear Your Stored ParametersRestore Your Parameters Installation Appendix C Installing a Modem Under LinuxUsing the Modem to Call the Internet Standard Linux Serial Port DefinitionsAnswering Calls Calling the ISPRS-232 Pin Descriptions Appendix D Pin DescriptionsLeased Line Pinouts RS-232 Cable PinoutsWeee Directive Appendix F Rohs HT/TS Substance Concentration #DB IndexRegisters

PN S000408C specifications

The Multi-Tech Systems PN S000408C is a versatile and compact communication device designed for a wide range of applications in various industries. This device is primarily known for its robust performance, making it an ideal choice for developing Internet of Things (IoT) solutions, machine-to-machine (M2M) communications, and other telemetry applications.

One of the main features of the S000408C is its ability to support multiple communication protocols, which enhances its flexibility and interoperability with different systems. This device can seamlessly integrate with cellular, Ethernet, and serial interfaces, providing users the capability to implement diverse connectivity solutions. Its versatility enables it to function effectively in remote monitoring, data logging, and industrial automation scenarios.

The S000408C is engineered to work with multiple wireless technologies, including LTE, GSM, and CDMA, ensuring reliable connectivity across various geographical locations. This feature is essential for applications where consistent communication is necessary, such as in asset tracking and fleet management. Additionally, the device is compatible with various network configurations, making it suitable for both urban and remote deployments.

In terms of characteristics, the device stands out with its compact design, which allows for easy installation even in space-constrained environments. It features a rugged enclosure that is built to withstand harsh conditions, making it ideal for outdoor use. The S000408C is also equipped with power management capabilities, allowing for energy-efficient operation, which is crucial for battery-powered applications.

Moreover, the Multi-Tech S000408C prioritizes security, as it comes with built-in encryption features to protect data integrity during transmission. This aspect is particularly important for industries dealing with sensitive information, such as healthcare and finance.

The configuration process of the S000408C is straightforward, supported by comprehensive documentation and user-friendly software tools. This makes it accessible to developers and engineers, enabling them to rapidly deploy solutions without extensive training.

In conclusion, the Multi-Tech Systems PN S000408C is a powerful tool for businesses and developers aiming to harness the power of connectivity in their operations. With its multi-protocol support, robustness, and security features, it is well-positioned to meet the demands of today's connected world. As industries continue to evolve with the integration of IoT technologies, devices like the S000408C will remain at the forefront of enabling communication and operational efficiency.