Multi-Tech Systems PN S000408C manual Remote Configuration Options, Diagnostic Options

Page 27

Chapter 3 – Using the Front Panel

Remote Configuration Options

The following LCDs are used to configure remote configuration options. For more information about remote configuration, see Chapter 5, “Remote Configuration.”

ENABLE/DISABLE R.C

Use the Æ and Enter buttons to turn remote configuration on or off.

REMOTE CONFIG. PASSWORD

Use to enter the remote configuration password. To scroll through a list of digits and characters, press the ÇÅ and È buttons. To go to the next position, press the Æ button. To back up or to exit without saving, press the Æ button several times. To save the password, press the Enter button.

Diagnostic Options

Use the following LCDs to turn loopback tests on and off.

ANALOG LOOPBACK

Press the Æ and Enter buttons to start the analog loopback test. The TEST IN PROGRESS LCD appears. To stop the test, press the Æ and Enter buttons again.

DIGITAL LOOPBACK

Press the Æ and Enter buttons to start the local digital loopback test. The TEST IN PROGRESS LCD appears. To stop the test, press the Æ and Enter buttons again. Same as the &T3 command.

REMOTE DIGITAL LOOPBACK

Press the Æ and Enter buttons to start the remote digital loopback test. The TEST IN PROGRESS LCD appears. To stop the test, press the Æ and Enter buttons again. Same as the &T6 command.

Note: Digital Loopback and Remote Digital Loopback tests must be performed using AT Commands. The LCD option to run these tests has been temporarily removed.

Phone Number Memory Options

Use the following LCDs to list, enter, and dial stored phone numbers. Up to four phone numbers can be stored. The number in memory location 0 is used for DTR dialing, if DTR dialing is enabled.

Note: Only 16 characters can be displayed at a time. To display characters 17–30, press the È button. To go to the previous LCD, press the Å button. To go to the next LCD, press the Æ button.

LIST PHONE NUMBERS

Press the Æ button several times to display the phone number stored in each memory location.

ENTER PHONE NUMBERS

Use to store up to four phone numbers in memory locations 0–3. Each number can have up to 30 characters. To scroll through a list of digits and characters, press the Ç Å and È buttons. To go to the next position, press the Æ button. To back up or to exit without saving, press the Æ button several times. To save the number, press the Enter button. Same as the &Z= commands.

DIAL STORED NUMBERS

Press the Æ and Enter buttons to dial a stored phone number. Same as the DS= commands.

Multi-Tech Systems, Inc. MT5600BA-V92 User Guide

27

Image 27
Contents MultiModem Revision Date Description Table of Contents Product Description Features FeaturesProduct Description About AT Commands Safety WarningsModem Compatibility Technical SpecificationsOperating Temperature Connect the Modem to Your PC InstallationTwo-Wire or Four-Wire Leased Line Connection Connect the Modem to Your SystemInstalling the Modem Driver Install the Modem DriverConnect the Modem to the AC Power Outlet Power-On TestUsing the LCD Panel Country or Region Codes Setting Your Country or Region CodeUsing AT Commands Using the Global WizardInstall PhoneTools Using the Front Panel Modem ConfigurationLED Indicators Option Selection Liquid Crystal Display LCDStatus Trunk Basic Options Trunk Basic Options Trunk Advanced Options Trunk Diagnostic Options Trunk Advanced Options Trunk Remote Configuration Options TrunkCaller ID Options Trunk Phone Number Memory Options TrunkCaller ID Region Select Setting Country/Region Codes TrunkStatus Functionality of Menu OptionsOnline Options Basic OptionsCommand Mode Options RS232 Options Advanced OptionsCallback Security Remote Configuration Options Diagnostic OptionsPhone Number Memory Options Region Select Options Caller ID OptionsLeased Line Operation Two-Wire / Four-Wire SetupDial Backup Four-Wire SetupDial Backup and Leased Line Restore Setup Remote Configuration Basic ProcedureSetup Changing the Remote Configuration Password Changing the Remote Escape Character Setup Procedures Callback SecurityTurning Callback Security On and Off Front Panel Method Assigning Callback PasswordsAssigning Callback Phone Numbers Calling Procedure Default Description Callback Security CommandsNone of the Indicators Light TroubleshootingModem Cannot Connect When Dialing Modem Does Not Respond to CommandsModem Disconnects While Online Modem Cannot Connect When AnsweringModem Doesn’t Work with Caller ID File Transfer Is Slower Than It Should BeData Is Being Lost There Are Garbage Characters on the MonitorFCC Part 68 Telecom Appendix a Regulatory ComplianceEMC, Safety, and R&TTE Directive Compliance Canadian Limitations NoticeInternational Modem Restrictions South African Notice New Zealand Telecom Warning NoticeIdentify the Modem Firmware Upgrade OverviewAppendix B Upgrading Firmware IntroductionClear Your Stored Parameters Download the Upgrade FileExtract the Upgrade Files Upgrade the Modem’s FirmwareRestore Your Parameters Standard Linux Serial Port Definitions Appendix C Installing a Modem Under LinuxInstallation Using the Modem to Call the InternetAnswering Calls Calling the ISPRS-232 Pin Descriptions Appendix D Pin DescriptionsLeased Line Pinouts RS-232 Cable PinoutsWeee Directive Appendix F Rohs HT/TS Substance Concentration #DB IndexRegisters

PN S000408C specifications

The Multi-Tech Systems PN S000408C is a versatile and compact communication device designed for a wide range of applications in various industries. This device is primarily known for its robust performance, making it an ideal choice for developing Internet of Things (IoT) solutions, machine-to-machine (M2M) communications, and other telemetry applications.

One of the main features of the S000408C is its ability to support multiple communication protocols, which enhances its flexibility and interoperability with different systems. This device can seamlessly integrate with cellular, Ethernet, and serial interfaces, providing users the capability to implement diverse connectivity solutions. Its versatility enables it to function effectively in remote monitoring, data logging, and industrial automation scenarios.

The S000408C is engineered to work with multiple wireless technologies, including LTE, GSM, and CDMA, ensuring reliable connectivity across various geographical locations. This feature is essential for applications where consistent communication is necessary, such as in asset tracking and fleet management. Additionally, the device is compatible with various network configurations, making it suitable for both urban and remote deployments.

In terms of characteristics, the device stands out with its compact design, which allows for easy installation even in space-constrained environments. It features a rugged enclosure that is built to withstand harsh conditions, making it ideal for outdoor use. The S000408C is also equipped with power management capabilities, allowing for energy-efficient operation, which is crucial for battery-powered applications.

Moreover, the Multi-Tech S000408C prioritizes security, as it comes with built-in encryption features to protect data integrity during transmission. This aspect is particularly important for industries dealing with sensitive information, such as healthcare and finance.

The configuration process of the S000408C is straightforward, supported by comprehensive documentation and user-friendly software tools. This makes it accessible to developers and engineers, enabling them to rapidly deploy solutions without extensive training.

In conclusion, the Multi-Tech Systems PN S000408C is a powerful tool for businesses and developers aiming to harness the power of connectivity in their operations. With its multi-protocol support, robustness, and security features, it is well-positioned to meet the demands of today's connected world. As industries continue to evolve with the integration of IoT technologies, devices like the S000408C will remain at the forefront of enabling communication and operational efficiency.