Multi-Tech Systems PN S000408C manual Remote Configuration, Basic Procedure

Page 32

Chapter 5 – Remote Configuration

Chapter 5 - Remote Configuration

Remote configuration is a network management tool that allows you to configure modems anywhere in your network from one location. With password-protected remote configuration, you can issue AT commands to a remote MultiModem II modem for maintenance or troubleshooting as if you were on-site.

Basic Procedure

The following steps are valid regardless of whether the connection is established by the local or the remote MultiModem II modem.

1.Establish a data connection with a remote MT5600BA-V92 modem.

2.Send three asterisks to initiate remote configuration. The remote modem responds:

Online Remote Access Remote password:

3.Type the remote configuration password, and then press ENTER. The default is “MULTITECH.” It is not case-sensitive.

If the password is incorrect, the word CONNECT appears, and the local modem is returned to online mode.

If the password is correct, an >AT_ command prompt appears.

4.Type AT commands to configure the remote modem. It is not necessary to precede the commands with “AT.”

5.When you have finished configuring the remote modem, type *E and press ENTER to exit remote configuration mode and return to online data mode. You can now break the connection in the normal way.

Note: The dialing command is not allowed in remote configuration mode.

Setup

Multi-Tech modems are shipped with a default setup password (MULTITECH). Because anyone who has an owner’s manual knows the default setup password, for security you should change the password and possibly also the remote configuration escape character.

Changing the Remote Configuration Password

The remote configuration password can be changed only from the front panel of the modem:

1.Turn on the modem.

2.Starting at the STATUS LCD, press È È È Æ Æ È Æ to access the ENTER PASSWORD LCD.

3.To change the password, press ÇÅ or È to select the first character of the password, and then press Æ to go to the next character. Repeat until you have entered the entire password.

4.To cancel the new password, press Æ until the password is erased. To save the new password, press the Enter button. The next time you remotely configure the modem you must use the new password.

Multi-Tech Systems, Inc. MT5600BA-V92 User Guide

32

Image 32
Contents MultiModem Revision Date Description Table of Contents Product Description Product Description FeaturesFeatures Safety Warnings About AT CommandsTechnical Specifications Modem CompatibilityOperating Temperature Installation Two-Wire or Four-Wire Leased Line ConnectionConnect the Modem to Your System Connect the Modem to Your PCInstall the Modem Driver Connect the Modem to the AC Power OutletPower-On Test Installing the Modem DriverSetting Your Country or Region Code Using the LCD Panel Country or Region CodesUsing the Global Wizard Using AT CommandsInstall PhoneTools LED Indicators Using the Front PanelModem Configuration Liquid Crystal Display LCD Option SelectionStatus Trunk Basic Options Trunk Basic Options Trunk Advanced Options Trunk Advanced Options Trunk Remote Configuration Options Trunk Diagnostic Options TrunkPhone Number Memory Options Trunk Caller ID Options TrunkSetting Country/Region Codes Trunk Caller ID Region SelectFunctionality of Menu Options StatusBasic Options Online OptionsCommand Mode Options Advanced Options RS232 OptionsCallback Security Phone Number Memory Options Remote Configuration OptionsDiagnostic Options Caller ID Options Region Select OptionsTwo-Wire / Four-Wire Setup Leased Line OperationFour-Wire Setup Dial BackupDial Backup and Leased Line Restore Setup Setup Changing the Remote Configuration Password Remote ConfigurationBasic Procedure Changing the Remote Escape Character Turning Callback Security On and Off Setup ProceduresCallback Security Assigning Callback Passwords Front Panel MethodAssigning Callback Phone Numbers Calling Procedure Callback Security Commands Default DescriptionTroubleshooting None of the Indicators LightModem Does Not Respond to Commands Modem Cannot Connect When DialingModem Cannot Connect When Answering Modem Disconnects While OnlineFile Transfer Is Slower Than It Should Be Data Is Being LostThere Are Garbage Characters on the Monitor Modem Doesn’t Work with Caller IDAppendix a Regulatory Compliance FCC Part 68 TelecomInternational Modem Restrictions EMC, Safety, and R&TTE Directive ComplianceCanadian Limitations Notice New Zealand Telecom Warning Notice South African NoticeUpgrade Overview Appendix B Upgrading FirmwareIntroduction Identify the Modem FirmwareDownload the Upgrade File Extract the Upgrade FilesUpgrade the Modem’s Firmware Clear Your Stored ParametersRestore Your Parameters Appendix C Installing a Modem Under Linux InstallationUsing the Modem to Call the Internet Standard Linux Serial Port DefinitionsCalling the ISP Answering CallsAppendix D Pin Descriptions RS-232 Pin DescriptionsRS-232 Cable Pinouts Leased Line PinoutsWeee Directive Appendix F Rohs HT/TS Substance Concentration Index #DBRegisters

PN S000408C specifications

The Multi-Tech Systems PN S000408C is a versatile and compact communication device designed for a wide range of applications in various industries. This device is primarily known for its robust performance, making it an ideal choice for developing Internet of Things (IoT) solutions, machine-to-machine (M2M) communications, and other telemetry applications.

One of the main features of the S000408C is its ability to support multiple communication protocols, which enhances its flexibility and interoperability with different systems. This device can seamlessly integrate with cellular, Ethernet, and serial interfaces, providing users the capability to implement diverse connectivity solutions. Its versatility enables it to function effectively in remote monitoring, data logging, and industrial automation scenarios.

The S000408C is engineered to work with multiple wireless technologies, including LTE, GSM, and CDMA, ensuring reliable connectivity across various geographical locations. This feature is essential for applications where consistent communication is necessary, such as in asset tracking and fleet management. Additionally, the device is compatible with various network configurations, making it suitable for both urban and remote deployments.

In terms of characteristics, the device stands out with its compact design, which allows for easy installation even in space-constrained environments. It features a rugged enclosure that is built to withstand harsh conditions, making it ideal for outdoor use. The S000408C is also equipped with power management capabilities, allowing for energy-efficient operation, which is crucial for battery-powered applications.

Moreover, the Multi-Tech S000408C prioritizes security, as it comes with built-in encryption features to protect data integrity during transmission. This aspect is particularly important for industries dealing with sensitive information, such as healthcare and finance.

The configuration process of the S000408C is straightforward, supported by comprehensive documentation and user-friendly software tools. This makes it accessible to developers and engineers, enabling them to rapidly deploy solutions without extensive training.

In conclusion, the Multi-Tech Systems PN S000408C is a powerful tool for businesses and developers aiming to harness the power of connectivity in their operations. With its multi-protocol support, robustness, and security features, it is well-positioned to meet the demands of today's connected world. As industries continue to evolve with the integration of IoT technologies, devices like the S000408C will remain at the forefront of enabling communication and operational efficiency.