Multi-Tech Systems PN S000408C manual Download the Upgrade File, Extract the Upgrade Files

Page 47

Appendix B – Upgrading the Firmware

5.If the firmware version number is greater than the firmware version number found in “Step 1: Identify the Modem Firmware,” your modem has an older firmware version. Continue with “Step 3: Download the Upgrade File.”

Warning: The first digit of the new firmware must match the first digit of the old firmware, or the modem may not work properly; e.g., if your current firmware version is 4.16, replace it only with 4.xx firmware, not 6.xx firmware.

Step 3 - Download the Upgrade File

1.If you are not already at the MultiModem II Firmware page of the Multi-Tech Web site, - follow the procedure in “Step 2: Identify the Current Firmware.”

2.Download the upgrade file for your modem by clicking its name, and save the file in a temporary folder on your hard disk.

3.In the same section of the Web page, click the Flash Wizard utility for your operating system to download it, and save it in the same folder.

Step 4 - Extract the Upgrade Files

1.Install the Flash Wizard utility by double-clicking the file name in Windows Explorer.

2.Extract the upgrade files by double-clicking the file name. The extracted files include a

.HEX file, which contains the upgrade data, and a Readme file.

3.Copy the upgrade .HEX file into the Flash Wizard folder, which, in a default installation, is at C:\Program Files\Multi-Tech Systems\Flash Wizard\.

Step 5 - Clear Your Stored Parameters

Before you flash your modem, you should record the parameters that are currently stored in it, so you can reprogram it after flashing. After you have recorded them, send the AT&F command to the modem to clear the stored parameters.

1.Run your favorite terminal program. If you are using Windows 2000+ / XP, you can use HyperTerminal.

2.In the program’s terminal window, type AT&V and press Enter to list your modem’s current parameters.

3.Record your parameters by saving the LCDs and sending them to your printer.

4.Type AT&F and press Enter to clear your stored parameters and reset your modem to factory default.

5.Close the terminal program.

Step 6 - Upgrade the Modem’s Firmware

Before you begin the following procedure, read the README.TXT file extracted from the upgrade archive file. Note the file name for the boot code (e.g., F35ALOAD.S37) and the file name for the new firmware (e.g., BKQG300G.HEX).

WARNING: Never install an older version of firmware over a newer version. Doing this WILL DESTROY THE FLASH PROM! If the flash PROM is destroyed, the modem must be sent in for repair.

1.Run Flash Wizard by double-clicking its icon or file name, or by selecting it from the Start menu. The Identifying Devices dialog box is displayed as Flash Wizard locates and identifies the devices connected to your system.

Note: If the message ERROR No valid devices detected is displayed, verify that the modem is turned on and that all cables are correctly and securely attached.

2.Click the modem to be upgraded, and then click Next to proceed.

3.Select the port to be upgraded from the Port list, select the appropriate .HEX file from the Hex File list, and then click Next to continue.

Note: Do not use FLASHLDR.HEX. This file is used internally by Flash Wizard.

4.The Progress dialog box appears, showing a status bar that indicates the progress of the upgrade.

Multi-Tech Systems, Inc. MT5600BA-V92 User Guide

47

Image 47
Contents MultiModem Revision Date Description Table of Contents Product Description Product Description FeaturesFeatures About AT Commands Safety WarningsModem Compatibility Technical SpecificationsOperating Temperature Connect the Modem to Your PC InstallationTwo-Wire or Four-Wire Leased Line Connection Connect the Modem to Your SystemInstalling the Modem Driver Install the Modem DriverConnect the Modem to the AC Power Outlet Power-On TestUsing the LCD Panel Country or Region Codes Setting Your Country or Region CodeUsing AT Commands Using the Global WizardInstall PhoneTools LED Indicators Using the Front PanelModem Configuration Option Selection Liquid Crystal Display LCDStatus Trunk Basic Options Trunk Basic Options Trunk Advanced Options Trunk Diagnostic Options Trunk Advanced Options Trunk Remote Configuration Options TrunkCaller ID Options Trunk Phone Number Memory Options TrunkCaller ID Region Select Setting Country/Region Codes TrunkStatus Functionality of Menu OptionsOnline Options Basic OptionsCommand Mode Options RS232 Options Advanced OptionsCallback Security Phone Number Memory Options Remote Configuration OptionsDiagnostic Options Region Select Options Caller ID OptionsLeased Line Operation Two-Wire / Four-Wire SetupDial Backup Four-Wire SetupDial Backup and Leased Line Restore Setup Setup Changing the Remote Configuration Password Remote ConfigurationBasic Procedure Changing the Remote Escape Character Turning Callback Security On and Off Setup ProceduresCallback Security Front Panel Method Assigning Callback PasswordsAssigning Callback Phone Numbers Calling Procedure Default Description Callback Security CommandsNone of the Indicators Light TroubleshootingModem Cannot Connect When Dialing Modem Does Not Respond to CommandsModem Disconnects While Online Modem Cannot Connect When AnsweringModem Doesn’t Work with Caller ID File Transfer Is Slower Than It Should BeData Is Being Lost There Are Garbage Characters on the MonitorFCC Part 68 Telecom Appendix a Regulatory ComplianceInternational Modem Restrictions EMC, Safety, and R&TTE Directive ComplianceCanadian Limitations Notice South African Notice New Zealand Telecom Warning NoticeIdentify the Modem Firmware Upgrade OverviewAppendix B Upgrading Firmware IntroductionClear Your Stored Parameters Download the Upgrade FileExtract the Upgrade Files Upgrade the Modem’s FirmwareRestore Your Parameters Standard Linux Serial Port Definitions Appendix C Installing a Modem Under LinuxInstallation Using the Modem to Call the InternetAnswering Calls Calling the ISPRS-232 Pin Descriptions Appendix D Pin DescriptionsLeased Line Pinouts RS-232 Cable PinoutsWeee Directive Appendix F Rohs HT/TS Substance Concentration #DB IndexRegisters

PN S000408C specifications

The Multi-Tech Systems PN S000408C is a versatile and compact communication device designed for a wide range of applications in various industries. This device is primarily known for its robust performance, making it an ideal choice for developing Internet of Things (IoT) solutions, machine-to-machine (M2M) communications, and other telemetry applications.

One of the main features of the S000408C is its ability to support multiple communication protocols, which enhances its flexibility and interoperability with different systems. This device can seamlessly integrate with cellular, Ethernet, and serial interfaces, providing users the capability to implement diverse connectivity solutions. Its versatility enables it to function effectively in remote monitoring, data logging, and industrial automation scenarios.

The S000408C is engineered to work with multiple wireless technologies, including LTE, GSM, and CDMA, ensuring reliable connectivity across various geographical locations. This feature is essential for applications where consistent communication is necessary, such as in asset tracking and fleet management. Additionally, the device is compatible with various network configurations, making it suitable for both urban and remote deployments.

In terms of characteristics, the device stands out with its compact design, which allows for easy installation even in space-constrained environments. It features a rugged enclosure that is built to withstand harsh conditions, making it ideal for outdoor use. The S000408C is also equipped with power management capabilities, allowing for energy-efficient operation, which is crucial for battery-powered applications.

Moreover, the Multi-Tech S000408C prioritizes security, as it comes with built-in encryption features to protect data integrity during transmission. This aspect is particularly important for industries dealing with sensitive information, such as healthcare and finance.

The configuration process of the S000408C is straightforward, supported by comprehensive documentation and user-friendly software tools. This makes it accessible to developers and engineers, enabling them to rapidly deploy solutions without extensive training.

In conclusion, the Multi-Tech Systems PN S000408C is a powerful tool for businesses and developers aiming to harness the power of connectivity in their operations. With its multi-protocol support, robustness, and security features, it is well-positioned to meet the demands of today's connected world. As industries continue to evolve with the integration of IoT technologies, devices like the S000408C will remain at the forefront of enabling communication and operational efficiency.