Troubleshooting – Safe Mode
Restoring Factory Defaults
To enter Safe mode:
1.While powering up Smartt 108/116 IP, press and hold down the Go Loccal button on the back panel of the uniit for three to four seconds.
The device boots up in Safe mode.
2.Wait until the unit finishees booting (one to two minutes).
3.Determine the IP addresss of the Smart 108/116 IP unit. The IP addresss depends on whether or not there is a DHCP server on the network. If there is, the DHCP server assigns an IP address to the Smart 108/116 IP unit. If there is no DHCCP server, the unit boots with the static IP address 192.168.2.155.
4.Open Internet Explorer and type into the Address box: http://IP addreess/config. (Do not start the addresss with https.)
The Login page appears.
Figure 46 – Login Page
5.In User, type username admin , and in Password, type SAFEmode (case sensitive). (This username and password works only in Safe mode.)
A menu appears.
Figure 47 – Safe Mode Menu
5.2 Restoring Facttory Defaults
You can restore all Smart 108/116 IP settings to their default values.
58 Smart 108/116 IP