For 10/100 Base-TX ports, plug a Category 5 (or better) twisted pair cable into one the RJ45 copper ports (1-6). Connect the other end to the far end station. Verify that the Port LED’s are ON once the connection has been completed. For Switch to Switch or Switch to Repeater connections, a crossover cable may be required if the connecting unit does not support the HP-MDIX auto cable detect feature. For 10/100BaseTX operation, the 600 Series Switch will sense & adapt accordingly.

A maximum number of 50 600 Series switches can be connected in a single ring.

CONNECTING MULTIPLE RINGS (608MFX Only)

For multiple rings, the connection between two network segments is made on two separate paths. Two of the 608MFX’s in a ring are connected together via a connection cable with an ITP cable (maximum length of 40m), and inform each other of their operating states. One of the 608MFX units is assigned the redundant function using the DIP switch setting “Stby on” (Standby Slave). The other 608MF X unit takes over the function of the Standby Master, with the DIP switch setting “Stby off” (see Figure 2). Please note that 604MFX units

cannot be used as Ring Couplers.

Because of the 50-unit ring limit, for larger networks, the user must configure multiple rings. By using the Master/Slave Standby approach to couple rings together, the user can enlarge the network by chaining segments.

Port Assignment in the Standby Mode

On the Standby Master and Standby Slave only port #1 (default standby port) can be used for the coupling to the neighboring ring. Connect the #1 ports together using a CAT5E crossover cable between switches. Ports 2-6 can be used just as normal switch ports.

Simultaneous Standby and Redundancy Manager Operation

A standby master or standby slave can adopt the function of a redundancy manager at the same time.

12/15/05

10

Image 10
Contents Hardware Installation Guide Industrial Ethernet Switch Installation Guide 12/15/05 Electrical Safety Laser Safety 604/608MFXE Version OnlySeries Industrial Ethernet Switch Key FeaturesInstallation Package ContentsUnpacking DIN-Rail Mounting Series Hazardous Location Installation RequirementsPersonnel Qualification Requirements Rack MountingApplying Power Connecting the Standard Ring Ring ManagerCannot be used as Ring Couplers Connecting Multiple Rings 608MFX OnlyPort Assignment in the Standby Mode Simultaneous Standby and Redundancy Manager OperationReplacing the Standby Master during operation 608MFXLED’s Fault red LED Displays and Operating ControlsDisplay Mode Meaning State = Port Status Port LED’sSelect/Set Button Ieee 802.1Q, Vlan Two-Pin Dip Switch SettingAging Time Ieee 802.1P, QOSSerial Interface Standby-Sync Port 608MFX OnlySerial Cable HyperterminalTroubleshooting FCC Statement12/15/05 Ordering Information Description Key Specifications Emissions and Safety ApprovalsWarranty Contact/Support InformationTron Limited Warranty 12/15/05