N-Tron 608MFX-ST, 604MFX-ST, 608MFXE-ST-40, 608MFXE-ST-80, 604MFXE-ST-40 manual Applying Power

Page 8

APPLYING POWER

1.Unscrew the flange & remove the DC Voltage Input Plug from the Header.

2.Install the DC Power Cables into the Plug(s) (observing polarity per the legend on the top of the unit). L1+ and L2+ are the +24V connections. M1 and M2 are the minus (-) returns for the L1 and L2 respectively. F1 and F2 terminals are across the contact switch that opens to signify a fault detection. Voltage/Current for F1/F2 is limited to 24V @ 100mA.

3.Plug the Voltage Input Plug back into the side header. All LED’s will flash ON Momentarily.

4.The unit will complete the power up cycle in approximately 20 seconds.

Note: Only 1 power supply is required to be connected to power for minimal operation. For redundant power operation, L1 and L2 terminals must be connected to separate DC Voltage sources. Use wire sizes 14-28 gauge.

Recommended 24V DC Power Supplies, similar to:

100VAC/240VAC:

N-Tron’s NTPS-24-1.3, DC 24V/1.3A,

Operating temp range -10°C to +60°C

12/15/05

8

Image 8
Contents Hardware Installation Guide Industrial Ethernet Switch Installation Guide 12/15/05 Electrical Safety Laser Safety 604/608MFXE Version OnlySeries Industrial Ethernet Switch Key FeaturesUnpacking Package ContentsInstallation Series Hazardous Location Installation Requirements Personnel Qualification RequirementsDIN-Rail Mounting Rack MountingApplying Power Connecting the Standard Ring Ring ManagerConnecting Multiple Rings 608MFX Only Port Assignment in the Standby ModeCannot be used as Ring Couplers Simultaneous Standby and Redundancy Manager OperationReplacing the Standby Master during operation 608MFXLED’s Fault red LED Displays and Operating ControlsDisplay Mode Meaning State = Port Status Port LED’sSelect/Set Button Two-Pin Dip Switch Setting Aging TimeIeee 802.1Q, Vlan Ieee 802.1P, QOSSerial Interface Standby-Sync Port 608MFX OnlySerial Cable HyperterminalTroubleshooting FCC Statement12/15/05 Key Specifications Emissions and Safety Approvals WarrantyOrdering Information Description Contact/Support InformationTron Limited Warranty 12/15/05