N-Tron 604MFX-ST, 608MFX-ST, 608MFXE-ST-40, 608MFXE-ST-80, 604MFXE-ST-40 Serial Cable, Hyperterminal

Page 17

Serial Cable

Connect the serial COM port of your PC and the 600 Series Switch using a normal null modem cable (or a straight through cable with a null modem adapter). You will require a cable with a 9-pin or 25-pin sub-D female connector for the PC end, and a 9-pin female sub-D connector for the 608MFX end.

The following table shows the pin-out and the connections for both types of cable:

PC Port

Signal Name

TXD

RXD

RTS

CTS

GND

DSR

DTR

25-Pin

9-Pin

 

604/608MFX

Female

Female

 

9-Pin Female

 

 

Pin

 

 

Pin #

Pin #

#

 

Signal Name

2

3

2

 

RXD

3

2

3

 

TXD

4

7

8

 

CTS

5

8

7

 

RTS

7

5

5

 

SG

6

6

4

 

DTR

20

4

6

 

DSR

Shielded cables and null modems are readily available from Radio Shack or a variety of computer shops.

Hyperterminal

The following configuration should be used in Hyperterminal:

Port Settings:

115200

Data Bits:

8

Parity:

None

Stop bits:

1

Flow Control:

None

12/15/05

17

Image 17
Contents Hardware Installation Guide Industrial Ethernet Switch Installation Guide 12/15/05 Laser Safety 604/608MFXE Version Only Electrical SafetyKey Features Series Industrial Ethernet SwitchUnpacking Package ContentsInstallation Personnel Qualification Requirements Series Hazardous Location Installation RequirementsDIN-Rail Mounting Rack MountingApplying Power Ring Manager Connecting the Standard RingPort Assignment in the Standby Mode Connecting Multiple Rings 608MFX OnlyCannot be used as Ring Couplers Simultaneous Standby and Redundancy Manager Operation608MFX Replacing the Standby Master during operationDisplays and Operating Controls LED’s Fault red LEDPort LED’s Display Mode Meaning State = Port StatusSelect/Set Button Aging Time Two-Pin Dip Switch SettingIeee 802.1Q, Vlan Ieee 802.1P, QOSStandby-Sync Port 608MFX Only Serial InterfaceHyperterminal Serial CableFCC Statement Troubleshooting12/15/05 Warranty Key Specifications Emissions and Safety ApprovalsOrdering Information Description Contact/Support InformationTron Limited Warranty 12/15/05