Multi-Tech Systems FR111 owner manual

Page 78

access circuit. Set the DLCI to indicate the PVC to terminate the trunk. The range of DLCIs is from 16 to 1007 with a default of 16.

The Committed Info Rate (CIR) option determines the data transfer rate at which the network is committed to handle under normal conditions. This rate is the average over a minimum increment of time. The CIR may be less than or equal to the Access Rate. When the CIR is ex- ceeded, but the data rate is below the Excess Burst Rate (Be), there is a possibility that data may be discarded. When the Be is exceeded, data will most likely be discarded. The default CIR is 32K.

The Excess Burst Rate (Be) option defines the maximum allowable data transfer rate the MultiFRAD can exceed the Committed Info Rate (CIR) during a time interval. The Be is the maximum additional data rate at which the MultiFRAD can present to the network during a time interval. The default Be is 24K.

The Management Type option defines a set of procedures and mes- sages to manage PVCs and the physical link at the user network interface. Three management types are used: Local Management Interface (LMI), Annex A, Annex D. The management type is determined by the network at subscription time.

The Polling Interval option defines a time period (T391) in which a Status Enquiry message is sent from the MultiFRAD to the network. The Status Enquiry message requests the status of the PVC(s) or verification of the status of a physical link. When the Status Enquiry message is sent by the MultiFRAD, the Polling Interval is restarted. The network responds with a status message that reports the status of the PVC or verifies the integrity of the physical link. The polling interval is 5 to 30 seconds with a default of 10 seconds.

The Full Status Counter option determines how many Polling Intervals take place before a full status (N391) is sent from the network. A Full Status Enquiry message is sent from the MultiFRAD to the network requesting status reports of all the PVCs on the physical link.

The Error Threshold Count option is used to indicate the threshold number of errors occurring during a full cycle of the Monitored Event Counter. After each full cycle of the Monitored Event Counter, if the actual number of errors equals or exceeds the error threshold, the trunk status is brought down and no data may be sent. The error count is reset at the beginning of each cycle of the Monitored Event Counter. The Error Threshold Count can range from 1 to 10 with a default of 3 and

78

Image 78
Contents Model FR111 Page Page Trademarks Contents Appendices Ascii Terminal Menu SystemIntroduction and Description Page Introduction MultiFRAD 100-SeriesAbout This Manual SetupSoftware Loading and Configuration Introduction and DescriptionService, Warranty and Tech Support Ascii Terminal Menu SystemTypical Application Ordering a Frame Relay LineHow to Configure a MultiFRAD Page Page FCC Regulations for Telephone Line Intercon- nection Page Canadian Limitations Notice Electrical/Physical/Environmental Specifications Data PortTrunk CompatibilityPage Front and Back Panel Descriptions Page Front Panel DataTrunk Data Connector Power ConnectorTrunk Connector Back PanelSwitch Settings DIP-SwitchesShunts ShuntsPage Setup Page Unpacking Safety Warnings DIP-Switch Settings Power Data V.35 Shunt ShuntsSoftware Loading Configuration Page Loading Software Page Page Configuring Your MultiFRAD using Windows Page Page Page Configuring your MultiFRAD using a Dumb Terminal NRZ C e s s r a t e 0 0 Enter Number, or P Previous Menu Page Selection Page Software Utility Descriptions Page MultiFRAD Main Menu Others Statistics Configuration Data PortDiagnostics DownloadHelp MultiFRAD VersionSync Mode Parameters Data Port ConfigurationMode Asynchronous/Synchronous SpeedInterFrame Timer in mS Between FramesEncoding Scheme Baud Rate CRC PresetAsync Mode Parameters Word LengthFlow Control ParityStop Bits PacingPass Xon EchoEIA Pass Through ENQ/ACK Trunk Configuration Data Link Connection Identifier DlciManagement Type Encapsulation Type Management Parameters Polling IntervalMonitored Event Error ThresholdFull Status Counter Committed Info Rate CIRBack to Back Excess Burst Rate BeStatistics Loop Tests Other TestsPage Ascii Terminal Menu System Page Configurations Menu Async Data Port Configuration CTSChannel Device Trunk Facility Sync Data Port Configuration NRZPage C e s s r a t e 0 0 Page Page Statistics View Statistics Page Reset Options Diagnostic TestsPage Watch Dog Test Flash Firmware UpgradeMemory Test Product and Firmware IDService, Warranty and Tech Support Page Limited Warranty Tech SupportRecording MultiFRAD Information Model Number Serial Number Firmware VersionService About the Multi-Tech BBSLogging on to the Multi-Tech BBS Downloading a FileAbout CompuServe If you don’t know the file nameAbout the Multi-Tech Fax-Back Service About the InternetUsing FlashPro to Upgrade MultiFRAD Firmware Upgrading the Flash PromPage Appendices Page Appendix a Cabling Diagrams Data connector RS232C/V.24 * CableTrunk Cable Pin IdentificationBack-To-Back Cable