3.2 System Setup

Selecting the 'DPCSS System Setup' line and pressing Enter will go into Set Up:

DPCSS System Setup

Version: 2.22

Auto scan duration: 10 sec

Error Message duration: 5 sec ignore Case in names

Server Name is Temporary

Port setup...

menu Window setup...

Server window setup...

Selecting “Port setup,” “menu Window setup,” or “Server window setup” will open one of three sub-menus to be discussed in the following pages.

The options at the main System Setup window can be selected by highlighting the desired option using the up/down arrows on your keyboard to select the option and scrolling through the values of each using either the +/- keys OR the “Enter” key to select your desired value.

Auto Scan Duration - Select the length of time, between 2 to 30 seconds, that each port will be scanned during auto scan.

Error Message Duration - Select the amount of time (2 to 15 seconds) each error message appears on the LCD as the system scans the ports.

Ignore Case in Names/Case Sensitive Names - This option lets you dictate whether the names entered in the “Jump to port...” mode need to be case sensitive, or not.

Server Name is Never On/Always On/Temporary - As you scroll through each port and/or as each port goes through auto scan, you have the option of having the Server Window with the connected port's name/number appear permanently, temporarily, or not at all.

Port Setup - discussed in a Section 3.3

Menu Window Setup - discussed in a Section 3.2.2

Server Window Setup - discussed in a Section 3.2.3

NOTE: System Setup options and values are automatically saved to the memory of the PC ServerSwitch 2x16.

www.lightwavecom.com

Page 11 of 24

Image 11
Contents September Lightwave Communications Table of Contents PC ServerSwitch 2x16 Front Panel PC ServerSwitch 2x16 IntroductionSpecifications PC ServerSwitch 2x16 featuresSystem Control PC ServerSwitch 2x16 System InformationVideo Keyboard / MouseNavigating the on-screen menus On-Screen MenusMain Menu Main Menu Options System Setup OptionsMain Menu Auto Scan Main Menu Jump to Port No Auto scan Enter port DisabledSystem Setup Prev unit Down System Setup Port SetupDpcss System Setup Menu Window SetupFront-panel LCD Display System Setup Server Window SetupFront Panel Controls Error MessagesOperational Safety Unpacking the Items InstallationInitial Start-Up PC ServerSwitch 2x16 Rear Panel View, ConnectionsPC Server Switch 2x16 -- Rear Panel Connections, 3 Servers Connecting CPUsCascading PC ServerSwitch 2x16 systems 3 units shown Cascading the PC ServerSwitchTurn the Auxiliary Unit On Connect Control CableConnect Video Cascade Cables Setting Factory Defaults System Maintenance FeaturesMaterials Flash Update StepsLightwave Communications