Linear RE-1 To Enter Programming Mode, To Exit Programming Mode & Save Changes, Call Forwarding

Page 28

RESIDENT PROGRAMMING QUICK REFERENCE

Some of the programming PPN’s may be commonly used by the resident. Following are quick references to the keystrokes required.

NOTE: The “###” is the default command prefix. The following example assumes that the default has not been changed.

To Enter Programming Mode

Press: Master Code

Master Code = the current 6-digit Master Programming Code

To Exit Programming Mode & Save Changes

Press:

Re-entering a Command After a Mistake

If an incorrect entry, or an incorrect key is pressed during programming, to clear the keypad:

Press:

Adding a Entry Code

Press: Code Code Relay Time Zone

Code = The new entry code: 1-999999, depending on code length

Relay = Relay output entry code will activate:

1 = Relay #1 2 = Relay #2 3 = Both Relays

4 = Relay #1 as priority user (no access restrictions)

Time Zone = 0 = no time zone; 1-7 to restrict access per time zone 1-7

Adding a Temporary Entry code

Press: Code Code Relay Time Zone Number

Valid From Valid Thru

Code = The new entry code: 1-999999, depending on code length Relay = Relay output entry code will activate:

1 = Relay #1 2 = Relay #2 3 = Both Relays

Time Zone = 0 = no time zone; 1-7 to restrict access per time zone 1-7 Number = Number of times (1-255) that the entry code is allowed access Valid From = First date (MMDDYY) that the entry code is valid

Valid Thru = Last date (MMDDYY) the entry code is valid.

Removing a Single Entry Code

Press: Code Code

Code = The entry code to remove.

Suspend or Activate a Single Transmitter

Press: Facility ID Action

Facility = Facility code 1-16 of transmitter (0 = no facility code)

ID = 5-digit ID number of transmitter

Action: 0 = Suspend transmitter; 1 = Re-activate transmitter

Maximum Number of Visitor Rings

Press: Rings

Rings = 1-15 Rings maximum

Visitor Talk Time Limit

Press: Limit

Limit = 15-255 Seconds allowed

Call Waiting Feature On/Off

Press: Call Waiting

Call Waiting: 1 = ON; 0 = OFF

Call Forwarding

Press: Forwarding Time Zone Telephone Number

Extension Delay

Forwarding: 0 = Call forwarding feature OFF

1 = Call forwarding feature ON at all times

2 = Call forwarding feature ON (scheduled by Time Zone) Time Zone = 1-7 (Call forwarding feature active during this Time Zone) Telephone Number = Up to 11-digit telephone number

Extension = Up to 4-digit telephone extension number

Delay = 1-25 seconds (delay between telephone number and extension)

Example:

Press: Telephone Number

“Do Not Disturb” Privacy Feature On/Off

Press:

 

 

 

Privacy

 

 

 

Time Zone

 

 

 

 

 

 

 

 

 

 

 

Privacy:

0

= Privacy feature OFF

 

1

= Privacy feature ON (scheduled by Time Zone)

 

2

= Privacy feature ON at all times

Time Zone = 1-7 (Privacy feature active during this Time Zone)

Automatic Door/Gate Open Time

Press:

 

 

Relay

 

 

 

1st Time Zone

 

 

 

2nd Time Zone

 

 

 

 

 

 

Relay:

1 = Relay #1

 

 

 

 

 

 

 

 

2 = Relay #2

 

 

 

 

 

 

 

1st Time Zone = Time Zone 1-7

2nd Time Zone = Time Zone 1-7 (enter “0” if the 2nd time zone is not used)

Setting Time Zones

Press: Time Zone Number Active Days Start Hour

Start Minute AM/PM End Hour End Minute AM/PM

Time Zone Number = 1-7

Active Days (Enter up to 8 digits):

1 = Sun; 2 = Mon; 3 = Tue; 4 = Wed; 5 = Thu; 6 = Fri; 7 = Sat; 8 = Holidays Start Hour = 1-12 Start Minute = 0-59 AM/PM: 0 = AM; 1 = PM

End Hour = 1-12 End Minute = 0-59 AM/PM: 0 = AM; 1 = PM

Setting the Holiday Days

Press: Holiday Number Month Day

Holiday Number = 1-10

Month = 1-12

Day = 1-31

26

Image 28
Contents RE-1 Contents FeaturesAccess Media System FeaturesProduct Description OperationInstallation Information Component Locations KeypadWiring Diagram Typical Gate Installation WiringTelephone Wiring Entry System MountingTelephone Wiring Options Intercom ModeRing Down Mode Shared LineCommand Prefix for Multiple Units Multiple Unit InstallationsShared Line Mode Gate Control Control WiringDoor or Pedestrian Gate Control POWER, BATTERY, & Ground Wiring Power WiringBackup Battery Optional Remote KeypadOptional Keyswitch Keyswitch InstallationCamera Installation Optional Cctv CameraProgramming with a Computer Programming AccessSystem Requirements NEW Connection Wizard will Start Click Next Select Networking TABClick Dial RE-1 willFrom the Start MENU, Click on Connect to Choose SET UP a DIAL-UP ConnectionFill in the Information for the Connection Connect WINDOW, Select Properties Click on CloseClick on USE the Following IP Address and Enter Connecting to the RE-1 with Windows Vista Click on Dial Start the ConnectionLocal Programming Access Remote Programming AccessProgramming with a Local Telephone or the Unit’s Keypad Remote Programming with a TelephoneProgramming Reference Programming ControlBasic System Programming Entry Code ProgrammingTransmitter Programming Telephone ProgrammingAdvanced System Programming Model MGT Gate Edge Transmitter Setup Relay #2 Alternate OptionsRemote Keypad Address Sense Input Alternate FunctionSpeakerphone Volume System AdjustmentsDigital Speech Volume RE-1 Operation To Enter Programming Mode To Exit Programming Mode & Save ChangesRe-entering a Command After a Mistake Call Waiting Feature On/OffDimension Drawing SpecificationsTroubleshooting Programming Worksheet Time ZonesEntry Code Relay # Time Zone Linear Limited Warranty Important Wireless Information