INSTALLATION INFORMATION
Before beginning installation, please review the entire instructions and become familiar with the system’s operation, wiring, and programmable options.
System Location
For pedestrian door or gate installations, mount the Entry System on a rigid wall near the controlled door. Avoid mounting the unit in a location where regular mechanical shock will occur due to a slamming door or spring loaded pedestrian gate.
For vehicular gate installations, mount the Entry System in clear view of the gate, but far enough from the gate so the user cannot touch the gate from the keypad.
★WARNING FOR ALL GATE INSTALLATIONS:TO AVOID SERIOUS INJURY OR DEATH, MAKE SURE THAT THE UNIT IS FAR ENOUGH FROM THE GATE SO THAT THE USER CANNOT TOUCH THE GATE WHILE OPERATING THE KEYPAD. HOWEVER, FOR SAFETY, THE GATE MUST BE FULLY VISIBLE FROM THE KEYPAD.
RFI Filter Installation
An
✦NOTE: To insure FCC Part 15 Class B compliance, the following steps must be performed at the time the
1.Open the ferrite RFI fi lter case by gently pulling on the side locking tab and swinging the case open (see Figure 1).
★CAUTION: The ferrite parts of the RFI filter are fragile.
DO NOT DROP THE FILTER ON A HARD SURFACE! Damage to the filter may result.
2.After completing the
✦NOTE: Be sure the filter is located no further than two inches from the rear case cover of the
NOTE: INSTALLATION OF THE RFI FILTER WILL
INSURE MAXIMUM RADIO RECEPTION RANGE
FOR ACCESS TRANSMITTERS
| RFI FILTER |
PULL ON PLASTIC TAB | INSTALLED |
WITHIN 2" | |
TO UNLOCK FILTER CASE | OF |
SWING FILTER
CASE OPEN
PHONE AND
TRANSFORMER WIRES
OUTSIDE OF FILTER
FERRITE
CORE
Figure 1. RFI Filter Installation
Telephone Wires
The quality of the system’s audio communications is related to the type of telephone wire and its installation. Noise and hum can be introduced into the telephone wires. Use only
•Minimum size of 24 AWG for up to 800 feet.
•Minimum size of 22 AWG for up to 1600 feet.
•Minimum size of 20 AWG for up to 2200 feet.
•Minimum size of 18 AWG for up to 3600 feet.
DO NOT ROUTE TELEPHONE AND AC WIRING INSIDE THE SAME CONDUIT. Route all telephone wires inside a dedicated conduit that is at least six inches away from any AC line wiring.
Power Supply
Use the supplied
DO NOT POWER ANY OTHER EQUIPMENT FROM THE SAME TRANSFORMER, use a separate power supply. Keep the system power wires as short as practical to reduce the chance of noise and hum pickup.
•For low voltage power wire runs up to 100 feet, use 18 AWG, THHN
•For low voltage power wire runs up to 200 feet, use 16 AWG, THHN
•Use 22 AWG or larger (depending on the load) for all other connections.
ALWAYS REMOVE POWER PRIOR TO SERVICING
Earth Ground
To avoid damage to the unit from static discharges, connect the
Removable Terminal Strips
For convenience, the
1.Be certain power is off before removing or installing these strips.
2.With a small screwdriver, gently slide the blade between the terminal strip and protective label.
3.Slightly pry fi rst one end, then the other, and then the middle. Repeat the process until the terminal strip can be removed straight off the circuit board by hand. Be very careful to not damage circuit board traces.
4.When
Do not remove or install one end fi rst.This will bend pins on the circuit board, which will damage the terminal strip internally. This damage is permanent and can not be repaired by simply straightening the pins on the circuit board.
✦NOTE: Unscrew the terminal screws several turns before inserting wires.
2