Table 7.1 | Problems and Suggested Solutions | |
|
|
|
Problem |
| Suggested Solution |
|
| |
One of the hard drives in a mirrored (RAID | Replace the failed drive with another drive that has the same or | |
1) array has failed. | greater capacity. | |
You insert a new drive with no | Press any key to enter the BIOS Configuration Utility | |
configuration into the slot which is already | configure the new drive. Mark the drive as one of the following: | |
part of a mirrored (RAID 1) array. | • Failed - If the AutoRebuild option is disabled in the configuration | |
|
| utility |
|
| • Rebuilding - If the AutoRebuild option is enabled in the |
|
| configuration utility |
You insert a new drive with no | Press any key to enter the BIOS Configuration Utility | |
configuration into the slot which is already | configure the new drive. | |
part of a striped (RAID 0) array or there is |
| |
a striped (RAID 0) array by itself in the |
| |
system. |
|
|
|
|
|
7.2Embedded SATA Software RAID Problem Report Form
Table