Table 6-5 Tunnel Accept Mode Settings

 

 

 

 

 

Tunnel Accept Mode

 

Description

 

Settings

 

 

 

Mode

 

Set the method used to start a tunnel in Accept mode. Choices are:

 

 

 

Disable = do not accept an incoming connection.

 

 

 

Always = accept an incoming connection (default).

 

 

 

Any Character = start waiting for an incoming connection when any

 

 

 

character is read on the serial line.

 

 

 

Start Character = start waiting for an incoming connection when the

 

 

 

start character for the selected tunnel is read on the serial line.

 

 

 

Modem Control Asserted = start waiting for an incoming connection as

 

 

 

long as the Modem Control pin (DSR) is asserted on the serial line until

 

 

 

a connection is made.

 

 

 

Modem Emulation = start waiting for an incoming connection when

 

 

 

triggered by modem emulation AT commands. Connect mode must

 

 

 

also be set to Modem Emulation.

 

 

 

 

 

Local Port

 

Set the port number for use as the network local port. The default local port

 

 

 

number for each supported serial line number progresses sequentially in

 

 

 

equal value so that Tunnel X : 1000X. For example:

 

 

 

Tunnel 1 : 10001

 

 

 

Tunnel 2 : 10002

 

 

 

 

 

Protocol

 

Select the protocol type for use with Accept Mode:

 

 

 

TCP (default protocol)

 

 

 

TCP AES

 

 

 

Telnet

 

 

 

 

 

TCP Keep Alive

 

Enter the time, in milliseconds, the XPort Pro Lx6 waits during a silent TCP

 

 

 

connection before checking if the currently connected network device is

 

 

 

still on the network. If the unit gets no response after 1 attempt, it drops

 

 

 

the connection. Enter 0 to disable.

 

 

 

 

 

Flush Serial

 

Set whether the serial line data buffer is flushed upon a new network

 

 

 

connection. Choices are:

 

 

 

Enabled = serial data buffer is flushed on network connection

 

 

 

Disabled = serial data buffer is not flushed on network connection

 

 

 

(default)

 

 

 

 

 

Block Serial

 

Set whether Block Serial is enabled for debugging purposes. Choices are:

 

 

 

Enabled = if Enabled, incoming characters from the serial line will not

 

 

 

be forwarded to the network. Instead, they will be buffered and will

 

 

 

eventually flow off the serial line if hardware or software flow control is

 

 

 

configured.

 

 

 

Disabled = this is the default setting; incoming characters from the

 

 

 

Serial Line are sent on into the network. Any buffered characters are

 

 

 

sent first.

 

 

 

 

 

Block Network

 

Set whether Block Network is enabled for debugging purposes. Choices

 

 

 

are:

 

 

 

Enabled = if Enabled, incoming characters from the network will not be

 

 

 

forwarded to the Serial Line. Instead, they will be buffered and will

 

 

 

eventually flow off the network side.

 

 

 

Disabled = this is the default setting; incoming characters from the

 

 

 

network are sent on into the Serial Line. Any buffered characters are

 

 

 

sent first.

 

 

 

 

XPort® Pro Lx6 Embedded Device Server User Guide

32

Image 32
Contents Embedded Device Server User Guide Warranty Intellectual PropertyContacts DisclaimerTable of Contents Line and Tunnel Settings Terminal and Host SettingsConfigurable Pin Manager Services SettingsMaintenance and Diagnostics Settings Advanced Settings Updating FirmwareBranding the XPort Pro Lx6 Appendix a Technical SupportList of Figures XPort Pro Lx6 Product LabelList of Tables XPort Pro Lx6 Embedded Device Server User Guide Using This Guide Purpose and AudienceSummary of Chapters Chapter DescriptionAdditional Documentation Document DescriptionApplications Key FeaturesIntroduction Protocol Support Troubleshooting CapabilitiesConfiguration Methods Addresses and Port Numbers Product Information LabelHardware Address IP AddressXPort Pro Lx6 Product Label Using DeviceInstaller Accessing XPort Pro Lx6 Using DeviceInstallerCurrent Settings Description Device Detail SummarySupports Configurable Pins GroupComments Device FamilyConfiguration Using Web Manager Accessing Web ManagerDevice Status 1Device StatusWeb Manager Components Help AreaWeb Manager Description See Navigating Web ManagerWeb Manager Pages Filesystem LineNetwork Protocol StackNetwork Settings Network Interface SettingsNetwork Interface Settings Network Interface Description SettingsTo Configure Network 1 Interface Settings Network Ethernet Network eth0 Link Settings Network 1 eth0 Link SettingsNetwork 1 Ethernet eth0 Description Link Settings To View Network 1 Interface StatusTo Configure Network 1 Link Settings Line and Tunnel Settings Line SettingsLine Configuration Settings Line Settings DescriptionLine Command Description Mode Settings To Configure Line SettingsLine Command Mode Settings To View Line Statistics Tunnel SettingsSerial Settings To Configure Tunnel Serial Settings Packing ModeTunnel Serial Settings Tunnel Packing Mode SettingsTo Configure Tunnel Packing Mode Settings Accept ModeTimeout Send CharacterTunnel Accept Mode Settings Tunnel Accept Mode Description SettingsTo Configure Tunnel Accept Mode Settings Connect ModeTunnel Connect Mode Settings Tunnel Connect Mode Description SettingsReconnect Timer HostTo Configure Tunnel Connect Mode Settings Disconnect ModeTunnel Disconnect Mode Settings Tunnel Disconnect Description Mode SettingsTo Configure Tunnel Disconnect Mode Settings Tunnel Modem Emulation SettingsTunnel Modem Description Emulation Settings Modem EmulationTo Configure Tunnel Modem Emulation Settings StatisticsTo View Tunnel Statistics Connect StringTerminal on Network and Line Settings Terminal and Host SettingsTerminal Settings To Configure the Terminal Network Connection To Configure the Terminal Line ConnectionConfigurable Pin Manager CPM Configurable PinsCurrent Configurable Pins CP StatusConfigurable Pin Manager CPM Group Current ConfigurationCPM Groups CPM Group StatusTo Configure CPM Settings Services Settings DNS SettingsTo View or Configure DNS Settings DNS SettingsFTP Settings Syslog SettingsTo Configure FTP Settings FTP SettingsHttp Settings To View or Configure Syslog SettingsHttp Settings Severity Log LevelTo Configure Http Settings To Configure Http AuthenticationHttp Settings Description Http Authentication Description SettingsUsing the CLI Maintenance and Diagnostics Settings Filesystem SettingsFile Display Settings File DisplayFile Modification Settings File Transfer SettingsFile Modification File TransferProtocol Stack Settings IP SettingsTo Configure IP Network Stack Settings Protocol Stack Description IP SettingsIcmp and ICMPv6 Settings To Configure Icmp Network Stack SettingsTo View ICMPv6 Network Stack Settings ARP SettingsTo Configure ARP Network Stack Settings Smtp SettingsTo Configure Smtp Network Stack Settings Default isDiagnostics Hardware To View Hardware InformationIP Sockets To View the List of IP SocketsPing Settings PingTo Ping a Remote Host TracerouteTo Configure the Diagnostic Log Output 10 Log SettingsLog MemoryThreads ProcessesTo View Process Information To View Thread InformationSystem Settings To Reboot or Restore Factory Defaults11 System Settings 12 CLI Configuration Default Settings13 Line Configuration Default Settings 14 Network Configuration Default Settings15 Tunnel Default Settings 16 Discovery SettingsAdvanced Settings Email SettingsTo View, Configure and Send Email Email Configuration Description SettingsCommand Line Interface Settings Basic CLI SettingsTo View and Configure Basic CLI Settings CLI Configuration SettingsXML Settings Telnet SettingsTo Configure Telnet Settings XML Export ConfigurationTo Export Configuration in XML Format XML Exporting ConfigurationXML Export Status Exporting StatusXML Import Configuration Import Configuration from Filesystem SettingsImport Configuration from Description Filesystem Settings To Export in XML FormatText List To Import Configuration in XML FormatWhole Groups to Import Updating Firmware Obtaining Firmware Loading New Firmware through Web ManagerLoading New Firmware through FTP Updating FirmwareBranding the XPort Pro Lx6 Web Manager CustomizationTo Customize Short or Long Names Short and Long Name SettingsShort and Long Name Customization Appendix a Technical Support North AmericaEurope, Middle East, Africa Emea Japan Asia / Pacific ApacOnline Appendix B Compliance Product Name ModelAppendix B Compliance RoHS NoticeAppendix C Binary to Hexadecimal Conversions Converting Binary to HexadecimalConversion Table Scientific CalculatorAppendix C Binary to Hexadecimal Conversions