Lantronix LX6 manual To Configure Line Settings, Line Command Mode Settings

Page 28

 

 

 

6: Line and Tunnel Settings

 

 

 

 

 

Line Settings

 

Description

 

Xon Char

 

Set Xon Char to be used when Flow Control is set to Software. Prefix decimal

 

 

 

with \ or prefix hexadecimal with 0x or prefix a single control character

 

 

 

<control>.

 

 

 

 

 

Xoff Char

 

Set Xoff Char to be used when Flow Control is set to Software. Prefix decimal

 

 

 

with \ or prefix hexadecimal with 0x or prefix a single control character

 

 

 

<control>.

 

 

 

 

 

Gap Timer

 

Set the Gap Timer delay to Set the number of milliseconds to pass from the

 

 

 

last character received before the driver forwards the received serial bytes.

 

 

 

By default, the delay is four character periods at the current baud rate

 

 

 

(minimum 1 msec). Gap Timer range is 1 to 5000 milliseconds (default value

 

 

 

is 4000 msec).

 

 

 

 

 

Threshold

 

Set the number of threshold bytes which need to be received in order for the

 

 

 

driver to forward received characters. Default value is 56 bytes.

 

 

 

 

 

 

Table 6-2 Line Command Mode Settings

 

 

 

 

 

Line Command

Description

 

Mode Settings

 

 

 

Mode

Set the Command Mode state of the Line. When in Command Mode, a CLI session

 

 

operates exclusively on the Line. Choices are:

 

 

Always

 

 

Use Serial String

 

 

Disabled

 

 

Note: In order to enable Command Mode on the Line, Tunneling on the Line must

 

 

be Disabled (both Connect and Accept modes). Also, custom baud rates are not

 

 

supported in Command Mode.

 

 

 

 

Wait Time

Enter the amount of time to wait during boot time for the Serial String. This timer

 

 

starts right after the Signon Message has been set on the Serial Line and applies

 

 

only if mode is “Use Serial String”.

 

 

 

 

Serial String

Enter the Text or Binary string of bytes that must be read on the Serial Line during

 

 

boot time in order to enable Command Mode. It may contain a time element to

 

 

specify a required delay in milliseconds x, formed as {x}. Applies only if mode is

 

 

“User Serial String”. It may contain a binary character(s) of the form [x]. For

 

 

example, use decimal [12] or hex [0xc].

 

 

 

 

Echo Serial String

Select Enable or Disable for Echo Serial String. Applies only if mode is “User Serial

 

 

String”. Select enable to echo received characters backed out on the line while

 

 

looking for the serial string.

 

 

 

 

Signon Message

Enter the string of bytes to be sent to the Serial Line during boot time. It may contain

 

 

a binary character(s) of the form [x]. For example, use decimal [12] or hex [0xc].

 

 

 

 

To Configure Line Settings

The following section describes the steps to view and configure Line 1 settings; these steps apply to other line instances of the device.

Using Web Manager

To configure a specific line, click Line in the menu and select Line 1 -> Configuration (Table 6-1).

XPort® Pro Lx6 Embedded Device Server User Guide

28

Image 28
Contents Embedded Device Server User Guide Warranty Intellectual PropertyContacts DisclaimerTable of Contents Line and Tunnel Settings Terminal and Host SettingsConfigurable Pin Manager Services SettingsMaintenance and Diagnostics Settings Advanced Settings Updating FirmwareBranding the XPort Pro Lx6 Appendix a Technical SupportList of Figures XPort Pro Lx6 Product LabelList of Tables XPort Pro Lx6 Embedded Device Server User Guide Using This Guide Purpose and AudienceSummary of Chapters Chapter DescriptionAdditional Documentation Document DescriptionIntroduction Key FeaturesApplications Configuration Methods Troubleshooting CapabilitiesProtocol Support Addresses and Port Numbers Product Information LabelHardware Address IP AddressXPort Pro Lx6 Product Label Using DeviceInstaller Accessing XPort Pro Lx6 Using DeviceInstallerCurrent Settings Description Device Detail SummarySupports Configurable Pins GroupComments Device FamilyConfiguration Using Web Manager Accessing Web ManagerDevice Status 1Device StatusWeb Manager Components Help AreaWeb Manager Pages Navigating Web ManagerWeb Manager Description See Filesystem LineNetwork Protocol StackNetwork Settings Network Interface SettingsNetwork Interface Settings Network Interface Description SettingsTo Configure Network 1 Interface Settings Network Ethernet Network eth0 Link Settings Network 1 eth0 Link SettingsNetwork 1 Ethernet eth0 Description Link Settings To View Network 1 Interface StatusTo Configure Network 1 Link Settings Line and Tunnel Settings Line SettingsLine Configuration Settings Line Settings DescriptionLine Command Mode Settings To Configure Line SettingsLine Command Description Mode Settings Serial Settings Tunnel SettingsTo View Line Statistics To Configure Tunnel Serial Settings Packing ModeTunnel Serial Settings Tunnel Packing Mode SettingsTo Configure Tunnel Packing Mode Settings Accept ModeTimeout Send CharacterTunnel Accept Mode Settings Tunnel Accept Mode Description SettingsTo Configure Tunnel Accept Mode Settings Connect ModeTunnel Connect Mode Settings Tunnel Connect Mode Description SettingsReconnect Timer HostTo Configure Tunnel Connect Mode Settings Disconnect ModeTunnel Disconnect Mode Settings Tunnel Disconnect Description Mode SettingsTo Configure Tunnel Disconnect Mode Settings Tunnel Modem Emulation SettingsTunnel Modem Description Emulation Settings Modem EmulationTo Configure Tunnel Modem Emulation Settings StatisticsTo View Tunnel Statistics Connect StringTerminal Settings Terminal and Host SettingsTerminal on Network and Line Settings To Configure the Terminal Network Connection To Configure the Terminal Line ConnectionConfigurable Pin Manager CPM Configurable PinsCurrent Configurable Pins CP StatusConfigurable Pin Manager CPM Group Current ConfigurationCPM Groups CPM Group StatusTo Configure CPM Settings Services Settings DNS SettingsTo View or Configure DNS Settings DNS SettingsFTP Settings Syslog SettingsTo Configure FTP Settings FTP SettingsHttp Settings To View or Configure Syslog SettingsHttp Settings Severity Log LevelTo Configure Http Settings To Configure Http AuthenticationHttp Settings Description Http Authentication Description SettingsUsing the CLI Maintenance and Diagnostics Settings Filesystem SettingsFile Display Settings File DisplayFile Modification Settings File Transfer SettingsFile Modification File TransferProtocol Stack Settings IP SettingsTo Configure IP Network Stack Settings Protocol Stack Description IP SettingsIcmp and ICMPv6 Settings To Configure Icmp Network Stack SettingsTo View ICMPv6 Network Stack Settings ARP SettingsTo Configure ARP Network Stack Settings Smtp SettingsTo Configure Smtp Network Stack Settings Default isDiagnostics Hardware To View Hardware InformationIP Sockets To View the List of IP SocketsPing Settings PingTo Ping a Remote Host TracerouteTo Configure the Diagnostic Log Output 10 Log SettingsLog MemoryThreads ProcessesTo View Process Information To View Thread InformationSystem Settings To Reboot or Restore Factory Defaults11 System Settings 12 CLI Configuration Default Settings13 Line Configuration Default Settings 14 Network Configuration Default Settings15 Tunnel Default Settings 16 Discovery SettingsAdvanced Settings Email SettingsTo View, Configure and Send Email Email Configuration Description SettingsCommand Line Interface Settings Basic CLI SettingsTo View and Configure Basic CLI Settings CLI Configuration SettingsXML Settings Telnet SettingsTo Configure Telnet Settings XML Export ConfigurationTo Export Configuration in XML Format XML Exporting ConfigurationXML Export Status Exporting StatusXML Import Configuration Import Configuration from Filesystem SettingsImport Configuration from Description Filesystem Settings To Export in XML FormatWhole Groups to Import To Import Configuration in XML FormatText List Updating Firmware Obtaining Firmware Loading New Firmware through Web ManagerLoading New Firmware through FTP Updating FirmwareBranding the XPort Pro Lx6 Web Manager CustomizationShort and Long Name Customization Short and Long Name SettingsTo Customize Short or Long Names Appendix a Technical Support North AmericaEurope, Middle East, Africa Emea Japan Asia / Pacific ApacOnline Appendix B Compliance Product Name ModelAppendix B Compliance RoHS NoticeAppendix C Binary to Hexadecimal Conversions Converting Binary to HexadecimalConversion Table Scientific CalculatorAppendix C Binary to Hexadecimal Conversions