GenTran ATS2001R manual Compatible Equipment, Compatible Generators, Compatible Circuit Breakers

Page 11

SECTION 2 – COMPATIBLE EQUIPMENT

2.1 Compatible Generators

In order for the OVATION™ Series ATS to function as designed, it must be connected to a permanently installed, automatic starting generator, with a continuous supply of fuel, such as gasoline, diesel, LPG or natural gas. Additionally, gasoline or diesel-powered generators must be equipped with automatic choke and electric/remote start. All OVATION™ Series ATS systems supports 2-wire (ON, +12V) or 4-wire (CRANK, ON, +12V, -12V) generator signaling.

Note: Many generators require additional control circuits to properly operate with OVATION™ Series ATS. Contact Gen/Tran or visit

http://www.gen-tran.com/content/support/installation_instructions.asp , see: Ovation™ Series ATS – Generator Connection Diagrams for additional information.

2.2 Compatible Circuit Breakers

Each OVATION™ Series ATS has been configured; factory tested and shipped with the UTILITY MAIN and GENERATOR MAIN circuit breakers installed. Compatible branch circuit breakers (supplied by installer) are as follows:

COMPATIBLE CIRCUIT BREAKER TYPES:

Siemens QAF (arc fault), QFH, QE, QEH, QFP, QNR, QNRH, QP, QPH, QF, QT, QPF (GFCI), QSAP (Surge Protector), HQP

Cutler-Hammer/Westinghouse Series BD, BR, BQ, GFC

Square D Series HOM*

GE Series THQL, THHQL (60 amp maximum)

*NOTE: Square D HOM series branch circuit breakers cannot be installed in the top right position on Models ATS2001D and ATS2001R. If you are planning to use Square D branch circuit breakers, please install them in other positions on the bus.

11

Image 11
Contents Ovation Series Safety Precaution Definitions Table of Contents General Description IntroductionStandard Configurations Retrofit NEW Construction or Retrofit How the Ovation Series Automatic Transfer Switch WorksKey Components Model ATS1001D/RModel ATS2002R Utility and Generator Source Circuit Breakers PowerPause Load Management Modules OptionalUser Interface Display UID Standards Compliance Remote PowerPause Relay Box OptionalSurge Protection Module Optional Compatible Circuit Breaker Types Compatible EquipmentCompatible Generators Compatible Circuit BreakersOther Items YOU MAY Need Preparing for InstallationPowerpause Load Management Priority Page Installation and Wiring Internal Wiring Diagrams Models ATS2001D/R Internal Wiring Diagrams Model ATS2002R Then Pull UP Here As a Generator subpanel Models ATS1001D/R ON/OFF RUN LoadCenter FunctionConnecting the Low Voltage Cable to the Generator Page Number Programming the SystemDial Name Model Generator ResetService TransferPreliminary Checks Startup and TestingEnergizing the Transfer Switch Testing the Transfer SwitchGenerator Battery Monitoring Re-Installing Covers and Labeling CircuitsProblem Possible Cause Solution Section TroubleshootingExercise, or Battery fails toButton commands Delay betweenProduct Registration Maintenance and ServiceMaintenance Exploded Views and Replacement Parts ListQTY PART# Description Type Model ATS1001DQTY PART# Description Type Model ATS1001RQTY Part Description Source Model ATS2001DQTY Description Source Model ATS2001RSource Model ATS2002RDescription 07/16/10 PN 530001 Rev D