GenTran ATS1001D, ATS2001R, ATS2001D, ATS1001R manual Model ATS2002R, Source

Page 34

Model ATS2002R, -22

ITEM

QTY

PART

DESCRIPTION

 

SOURCE

 

1

4

17728

Corner pad, polystyrene, 5.75x5.75x6.87, not shown

A

 

2

2

29880

Screw, 10-32x.5, RHPS, steel, zinc

C

 

3

1

32390

Screw, 8-32x.75, Hex, thread cutting, steel, zinc

C

 

4

8

32403

Screw, 8-32x.3/8, Hex, Type F, steel, zinc

C

 

5

4

32438

Screw, 10-32x.375, Type 23, Hex, steel, zinc

C

 

6

1

50512

Neutral/ground block assembly

B

 

7

1

50401

Enclosure, 200A ATS, 18x24, AL, NEMA 3R

B

 

8

1

50402

Cover, 200A ATS, NEMA 3R

B

 

9

1

50404

Cover, dead front, 200A ATS

B

 

10

1

50479

Label, carton, ATS Ovation™, 2002R, not shown

A

 

10-22

1

50479-22

Label, carton, ATS Ovation™, 2002R-22, not shown

A

 

11

1

50482

Actuator/Interlock Assm 200/200

B

 

12

1

50485

Label, circuit marking, not shown

A

 

13

1

50486

ATS Ovation™ Specification Sheet, not shown

D

 

14

1

50487

Screw, 8-32x1 PFL TAPT ST ZP

C

 

15

1

50488

Motor Assembly

 

B

 

16

1

50489*

Control Module Assembly

B

 

17

1

50497

Fuse Block, 20A, 600VAC, 10K AIC

B

 

17-22

1

50506

Fuse Block, 20A, 600VAC, 100K AIC

B

 

18

2

50498

Fuse 5A, 600VAC, 10K AIC

B

 

18-22

2

50507

Fuse 5A, 600VAC, 100K AIC

B

 

19

1

50500

Buss Assembly, 12 circuit, plastic, CU/TN

B

 

20

1

50502

Box, 21 3/8x7x26 7/8 PF-FOL, not shown

A

 

21

1

50582

Cable, motor to controller, 28" , 22AWG

B

 

22

1

50585*

Cable, AC voltage sense, 18AWG w/xformer

B

 

23

1

50590

Cable, current sense, 18AWG

B

 

24

1

50595

Cable, fuse block, 18AWG

B

 

25

1

51037

Warranty reply card, not shown

A

 

26

1

51080

Options Order Sheet, not shown

A

 

27

2

51101

Circuit breaker 200A, 2 pole, 120/240V, 10K AIC

B

 

27-22

1

511011

Circuit breaker 200A, 2 pole, 120/240V, 22K AIC

B

 

28

1

51121

Screw, Thumb grip, SS, 8-32x1.125"

B

 

29

1

51147

Label, GENTRAN, silver/green (340) , not shown

A

 

30

1

510950

Pigtail, neutral bond, 4AWG, green, 6"

B

 

31

1

72008

Label, "Gen, Util", ATS2002R, not shown

A

 

32

1

72009

Label, SN, not shown

A

 

33

1

72010

Label, SN, Control Module, not shown

A

 

34

2

72914

Screw, 8-32x.5, PTH, SS, SMS

C

 

35

1

500502

DO NOT RETURN card, not shown

A

 

36

1

510491

Label, 2" diam,

clear, not shown

A

 

37

1

530001

Manual: Installation, Operating and Maintenance, not shown

D

 

38

1

3700091-05

Label, product, ATS Ovation™, 2002R, 10K AIC, not shown

A

 

38-22

1

3700091-11

Label, product, ATS Ovation™, 2002R, 22K AIC, not shown

A

 

39

2

S7956W

Label, date code, .4375x.75, white, not shown

A

 

40

4

50509

Cable clip, Nylon 66, natural, large

B

 

41

1

50511

Cable clip, Nylon 66, natural, small

B

 

42

1

41029

Rivet, AL, .1875 x .376-.500, large flange

C

 

43

1

27408

Screw, 8-32x.1.25, RHMS, steel, zinc

C

 

44

1

50508

Screwdriver, mini, .100 straight blade, GT logo, not shown

A

 

TYPE:

 

 

 

 

 

 

A = Non-Field Replaceable Item (Call Factory)

B = Field Replaceable Item (Call Factory to order parts)

C = Available at local hardware store or home center

D = Download from www.-gen-tran.com website

*NOTE: When electrical parts marked with * are replaced, an ATS calibration procedure must be performed. Contact Gen/Tran for System Calibration Instructions, PN 530005.

34

Image 34
Contents Ovation Series Safety Precaution Definitions Table of Contents Introduction General DescriptionStandard Configurations How the Ovation Series Automatic Transfer Switch Works Retrofit NEW Construction or RetrofitModel ATS1001D/R Key ComponentsModel ATS2002R User Interface Display UID PowerPause Load Management Modules OptionalUtility and Generator Source Circuit Breakers Surge Protection Module Optional Remote PowerPause Relay Box OptionalStandards Compliance Compatible Circuit Breakers Compatible EquipmentCompatible Generators Compatible Circuit Breaker TypesPreparing for Installation Other Items YOU MAY NeedPowerpause Load Management Priority Page Installation and Wiring Internal Wiring Diagrams Models ATS2001D/R Internal Wiring Diagrams Model ATS2002R Then Pull UP Here As a Generator subpanel Models ATS1001D/R Function LoadCenter ON/OFF RUNConnecting the Low Voltage Cable to the Generator Page Dial Name Model Programming the SystemNumber Transfer ResetService GeneratorTesting the Transfer Switch Startup and TestingEnergizing the Transfer Switch Preliminary ChecksRe-Installing Covers and Labeling Circuits Generator Battery MonitoringTroubleshooting Problem Possible Cause Solution SectionDelay between Battery fails toButton commands Exercise, orExploded Views and Replacement Parts List Maintenance and ServiceMaintenance Product RegistrationModel ATS1001D QTY PART# Description TypeModel ATS1001R QTY PART# Description TypeModel ATS2001D QTY Part Description SourceModel ATS2001R QTY Description SourceModel ATS2002R SourceDescription 07/16/10 PN 530001 Rev D