SECTION 8 – MAINTENANCE AND SERVICE

8.1 Maintenance

To ensure that the generator will always be ready when required, it is important to start and exercise the generator regularly and keep the fuel tank filled with fresh fuel IF GASOLINE OR DIESEL. From the factory, the OVATION™ transfer switch will automatically perform the exercise program at least once every 7 days (installer-programmable from 0 to 28 days). It is not necessary to turn off any circuits in the load center when supplying generator power to the system, even when the utility power is operating normally. The system prevents back feeding generator power to the utility and, conversely, utility power to the generator.

There are no user-serviceable parts inside the OVATION™ Series ATS. For service, please contact your installer or Gen/Tran at 1-888- GEN-TRAN. NOTE: Gen/Tran warranty does NOT cover products that have been subject to misuse or unauthorized repair.

NOTE TO INSTALLER:

Please provide your company name and phone number inside the front door so that the customer will be able to contact you for service-related issues.

8.2 Factory Default Settings

Factory default settings at time of shipment are:

GENERATOR SIZE:

25Kw

GENERATOR EXERCISE SCHEDULE:

7 days

• TRANSFER LOAD DURING EXERCISE:

NO

• GENERATOR START DELAY AFTER UTILITY LOSS:

5 seconds

8.3 Product Registration

Complete enclosed Product Registration card and mail to GenTran to ensure you receive notification of product updates/bulletins.

8.4 Exploded Views and Replacement Parts List

Incorrect parts replacement and/or service can result in severe personal injury, death and/or equipment damage. Use only recommended GenTran service parts. Service personnel must be trained to perform electrical and mechanical service.

NOTE: When electrical parts marked with * are replaced, an ATS calibration procedure must be performed. Contact Gen/Tran for System Calibration Instructions, PN 530005.

29

Image 29
Contents Ovation Series Safety Precaution Definitions Table of Contents General Description IntroductionStandard Configurations Retrofit NEW Construction or Retrofit How the Ovation Series Automatic Transfer Switch WorksKey Components Model ATS1001D/RModel ATS2002R Utility and Generator Source Circuit Breakers PowerPause Load Management Modules OptionalUser Interface Display UID Standards Compliance Remote PowerPause Relay Box OptionalSurge Protection Module Optional Compatible Generators Compatible EquipmentCompatible Circuit Breakers Compatible Circuit Breaker TypesOther Items YOU MAY Need Preparing for InstallationPowerpause Load Management Priority Page Installation and Wiring Internal Wiring Diagrams Models ATS2001D/R Internal Wiring Diagrams Model ATS2002R Then Pull UP Here As a Generator subpanel Models ATS1001D/R Center LoadFunction ON/OFF RUNConnecting the Low Voltage Cable to the Generator Page Number Programming the SystemDial Name Model Service ResetTransfer GeneratorEnergizing the Transfer Switch Startup and TestingTesting the Transfer Switch Preliminary ChecksGenerator Battery Monitoring Re-Installing Covers and Labeling CircuitsProblem Possible Cause Solution Section TroubleshootingButton commands Battery fails toDelay between Exercise, orMaintenance Maintenance and ServiceExploded Views and Replacement Parts List Product RegistrationQTY PART# Description Type Model ATS1001DQTY PART# Description Type Model ATS1001RQTY Part Description Source Model ATS2001DQTY Description Source Model ATS2001RSource Model ATS2002RDescription 07/16/10 PN 530001 Rev D