Magnum 6KQ Managed Field Switch Installation and User Guide | (04/07) |
The Alarm Contacts are on the front left area (next to the DC power source) of the Magnum 6KQ unit and are green in color as shown in the picture.
3.66KQ Port Module (6KPM) Installation
Magnum 6KQ Switches are normally received from the factory with all
required 6K Port Modules installed.
NOTE: There may be situations where the 6K PMs need to be added or replaced. Any change in configuration of the modules can be done only via factory installation. There is no field upgrade option for 6KQ port modules. Please contact Tech Support (support@garrettcom.com) / RMA(rma@garrettcom.com) for changing modules.
The 6KQ port modules are not compatible with or
3.7Connecting a Management Console Terminal to Magnum 6KQ
The serial console port on the Magnum 6KQ is different from other
The Serial port
8 | 1 |
8 pin RJ45 female connector at the Magnum 6KQ front panel
Female
connector
Pin | Name | Description | Dir |
1 | RTS | Request To Send | OUT |
3 | TXD | Transceiver Data | OUT |
4 | GND | Ground | - |
5 | GND | Ground | - |
6 | RXD | Receive Data | IN |
8 | CTS | Clear To Send | IN |
8 1
Front
8 pin RJ45 male connector at the cables
Male
connector
www . GarrettCom . com