GarrettCom 6K25e manual Flow-control, Ieee 802.3x standard

Page 46

Magnum 6K25e Gigabit Fiber Switch

Installation and User Guide (10/07)

arrive at the highest order mode that both devices can support at that time. (Since auto- negotiation is potentially an externally controlled process, the original “highest order mode” result can change at any time depending on network changes that may occur). If the device at the other end is not an auto-negotiating device, the 6K25e’s RJ-45 ports will try to detect its idle signal to determine 10 or 100 speed, and will default to half- duplex at that speed per the IEEE standard.

General information -

Auto-negotiation per-port for 802.3u-compliant switches occurs when:

--the devices at both ends of the cable are capable of operation at either 10 Mb or 100Mb speed and/or in full- or half-duplex mode, and can send/receive auto-negotiation pulses, and . . .

--the second of the two connected devices is powered up*, i.e., when LINK is established for a port, or

--the LINK is re-established on a port after being lost temporarily.

NOTE Some NIC cards only auto-negotiate when the computer system that they are in is powered up. These are exceptions to the “negotiate at LINK – enabled” rule above, but may be occasionally encountered.

When operating in 100Mb half-duplex mode, cable distances and hop-counts

may be limited within that collision domain. The Path Delay Value (PDV) bit-times must account for all devices and cable lengths within that domain. For Magnum 6K25e Fast Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.

4.5Flow-control, IEEE 802.3x standard

Magnum 6K25e Switches incorporate a flow-control mechanism for Full- Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a long burst of activity causes the switch to save frames until its buffer memory is full. This is most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the 10Mb port is unable to keep up. It can also occur when multiple 100Mb ports are attempting to transmit to one 100Mb port, and in other protracted heavy traffic situations.

www . GarrettCom . com

40

Image 46
Contents Gigabit Fiber Switch Trademarks Contacting GarrettCom, Inc Canadian EmissionTable of Contents Introduction6K25E Managed Fiber Switch Port Modules RevisionsMagnum Line Network Standards and Compliance, hardware Technical SpecificationsPerformance Maximum 10 Mbps Ethernet Segment LengthsManagement Console connector Fiber Multi-mode connector types supportedFiber Single-mode connector types Power Supply InternalPer-port MDI or Mdix on RJ-45 Alarm Contact OptionalNebs Testing and Certification Nebs certified Agency ApprovalsOrdering Information For Gigabit module configuration options 6K PoE Modules with 48VDC Pass-Through6K PoE Modules with 48VDC Power Inside Product Description Magnum 6K25e Managed Fiber Switch Introduction Inspecting the Package and ProductWww . GarrettCom . com Magnum 6K25e and 6K25eR chassis Eight-port SFF fiber modules 6K8-MTRJ, 6K8-MLC, 100Mb fiberPort modules for the Magnum 100Mb fiber eightEight-Port Copper Module, 6K8-RJ45 The 6K25e-Series’s8-port New PoEPower Inside, model PI6KP8-45RJ MDIX, 10/100Mb 8-port Per the IEEE802.3af PoE Four-Port 10 Mb mm Fiber ST Modules Gigabit 1000Mbps port modules Packet Prioritization, 802.1p QOS Frame Buffering and Flow ControlManaged Network Software MNS-6K for Magnum 6K25e-Series Web-browser, at ftp//ftp.garrettcom.com„ Features Fiber-Built-In „ Managed switching for high performance Ethernet LANs„ Nebs and Etsi tested and certified „ RJ-45 ports are MDI/MDIX supported „ SFP Gigabit module being supported on Slot DApplications 6K 25e Installation Locating Magnum 6K25e SwitchesIeee Standard Media Type Max. Distance Port Module Fiber Connecting Ethernet MediaConnecting Fiber Optic ST-type, twist-lock CopperConnecting Single-Mode Fiber Optic Connecting Fiber Optic SC-type, Snap-InMedia Ieee Standard Media Ieee Standard Side View Duplex LC connector Front view Gigabit SFP Small Form-factor Pluggable Optical TransceiversTable-Top or Shelf Mounting SFP-SX SFP-LX10 SFP-LX25 SFP-ZX40 SFP-ZX70Rack-mounting for 19 Retma racks, regular Magnum 6K25es 1 Mountings for Magnum 6K25e units rack-mounted in a framePowering the Magnum Managed Fiber Switch Rack-mounting, Reverse version of the Magnum 6K25esWww . GarrettCom . com Preparation for Installing and Removing 6KPMs 6K25e Port Module 6KPM InstallationRemove Chassis Cover 1a Removing Chassis Cover Installing 6KPM Cards in the Magnum 6K25e Uplink 2f Securely latching up 6KPM Cards into a Magnum 6K25e Removing 6KPM Cards Console DB-9 Port Connecting the Console Terminal to Magnum 6K25e ManagementRemove 6KPM Card DB-9 Console port connector Pin Signal Description Switching Functionality 1 RS-232 DB-9 Console Com port Serial port pin assignmentsPWR Status LEDsUp-link MDI-MDIX on RJ-45 port modules, for port 1 only ACTAuto-CrossMDIX and Auto-negotiation, for RJ-45 ports Flow-control, Ieee 802.3x standard F10ST Introduction Magnum 6K25e Managed Fiber Switch Port Modules 6KPM Module Description 1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST twist lock Module @10Mb @100Mb Multi-mode FX-ST twist 1c 6KP4Lock Module Fiber functions in one Module of the 6K25e Switch Mode 100Mbps fiber opticMode SC-type connectors. It Provides an advantage Transceivers all in one module. ThisWww . GarrettCom . com Activity FULL/HALF Port@ 100Mbps Multi-Mode Fiber portLink Form Factor 9 6KP8-RJ45 Twisted Pair, 10/100Mb 8-Port Option in one 6K-unit PoE LEDs Summary Fig. the top 8-RJ4510/100 GBIC-SXSC Gigabit fiber1000Mb, multi-mode SC Connector 14 6KM-BLNK Before Calling for AssistanceWhen Calling for Assistance Return Material Authorization RMA ProcedureNo Problem Found Shipping and Packaging InformationSpecifications for Magnum 6K25E SWITCHES, DC Power Appendix B Internal DC Power Supply OptionsB3.0 Applications for DC Powered Switches B4.0 Installation Magnum 6K25es. see figure at rightB7.0 Troubleshooting Appendix C Internal DC Dual-Source Power OptionB4.1 UL Requirements for DC-powered units B5.0 OperationC4.0 Features and Benefits of the DUAL-SOURCE Design C5.0 InstallationExample Magnum 6K25eR-48VDC C5.1 UL RequirementsC6.0 Ordering Information Example Magnum 6K25eR-24VDC or Magnum 6K25eR-125VDCC7.0 Operation