SOFTWARE OVERVIEW

NAVIGATION WINDOW The navigation window in EnerVista P485/D485 Setup is the main tool for selecting the different levels of the configuration. There are three main levels in the navigation window, namely fieldbus, P485, and Modbus network.

Menu entries preceded by a plus symbol (+) contain more configuration parameters or sub-menus. To gain access to these parameters, the entry must be expanded by clicking the ‘+’ symbol.

By right-clicking entries in this window, a popup menu with functions related to this entry will appear. The options in this popup menu is often also available in the menu bar.

PARAMETER WINDOW The parameters available in this window is different depending on what is selected in the navigation window. It consists of a grid with parameter names and, on the same row, a field for editing.

The parameters can be displayed in two modes: alphabetic and categorized. Parameter values are entered either using selection box or by entering a value. Values can be entered either in decimal form (for example, 35) or in hexadecimal form (for example, 0x1A).

If a value is entered in decimal format, it will be converted automatically to the equivalent hexadecimal value.

INFORMATION WINDOW In the right bottom corner of EnerVista P485/D485 Setup, below the parameter window, lies the information window. It contains descriptions of currently marked parameter instances.

Figure 4-4: Information window

CONFIGURATION LINE In the lower-right corner of the main window, two lights indicate if a connection has been INDICATOR established between the PC running EnerVista P485/D485 Setup and P485. A green light

indicates that the connection is OK, and a red light indicates no connection.

4–10

P485 MODBUS TO PROFIBUS CONVERTER – USER GUIDE

Image 32
Contents P485 Modbus to Profibus Converter GE MultilinPage Table of contents P485 Modbus to Profibus ConverterSoftware Frame Miscellaneous Introduction Getting startedDocument conventions Input and output definitionAbout the P485 Modbus to Profibus Converter FeaturesFeatures Specifications Mechanical HousingOrdering CommunicationsElectrical installation InstallationQuick install Profibus connector pin assignments Pin Signal DescriptionConfiguration cable pin assignments P485 end Pin DescriptionConfiguration cable PC end Mechanical installation Indicators and switchesP485 status indicators Number Description State StatusProfibus installation procedure Input/output bytes required ModulesTroubleshooting Poor performanceData exchange OverviewAddress Contents Access Memory MapProtocol configuration BlocksData Exchange Introduction Installation procedureSoftware overview Using the EnerVista P485/D485 Setup software Select Configuration Wizard and click on OKTypical network arrangement Sub-network data flow Address Command Software Overview P485 Modbus to Profibus Converter User Guide Software Overview Configuration main window Configurator main windowInformation window Fieldbus configuration Function DescriptionP485/D485 configuration P485/D485 configurationModbus network configuration Parameter Description RangeSoftware Overview Communication model PLCBasic settings P485 scan listNodes MenuCommunication Model P485 Modbus to Profibus Converter User Guide Communication Model Frame and command editors Frame editorCommand editor Select command windowSelect ‘Add Command’ as described earlier Query ColumnMain window Modbus network and node monitors Modbus network monitorStart / Stop sub network scanning Update OFF Update on Node monitorCommand Area Advanced functions Control and status registersBits Name Description Code Name DescriptionCode Error Description Handshake bits themselves bits 14Input/output data during startup Fieldbus control systemAdvanced fieldbus configuration Mailbox commandAdvanced Functions Application example OverviewFor the MM2, we have Type Parameter Address Format Read/writeModbus user map setup Parameter User map data AddressMM2 meter user map setting System configuration System configurationSetup Software Starting Configuration Wizard DB9 pin DescriptionSelecting the SUB-NETWORK Properties Modbus network propertiesParameters configured for Pqmii Connect Devices to the SUB- Network 11 Connect devices to sub-networkSelect Parameters for Each Node 14 Select parameter window17 Configuration report 20 Save device file Queries21 Expanding the tree 23 Changing configuration parameters for a query 25 Opening a saved configuration file Profibus network setup Warranty MiscellaneousRevision history Release Dates10-2 P485 Modbus to Profibus Converter Index 6-3Power Supply