GE P485 instruction manual Fieldbus configuration, Function Description

Page 33

SOFTWARE OVERVIEW

OPTIONS WINDOW In the main window under tools, select options.

Table 4–1: Options window functions

Function

Description

 

 

Warning on delete

When something is to be deleted, a warning window will appear.

 

 

Warning on unsaved

When closing EnerVista P485/D485 Setup with unsaved data, a

data

warning window will appear.

 

 

Show Wizard when

Each time a new configuration is to be made, the Wizard window will

“New” menu is selected

appear.

 

 

Language next time the

Select which language the program should use the next time the

program is launched

program is launched. Presently, only English is supported.

 

 

Size of log buffer

Set the size of the log buffer (0 to 512 bytes).

 

 

Firmware download

Download the firmware to the P485. Use with caution.

 

 

Factory restore

Restores the software on the P485 carrier board, to it´s original state.

 

 

Block configuration

Use with caution. When this button is pressed, the configuration will

 

not be accessible and a new configuration has to be downloaded to

 

the module.

 

 

Create error log

Creates an error log file.

 

 

Fieldbus configuration

DESCRIPTION During start-up, the fieldbus interface is initialized to fit the configuration created in the EnerVista P485/D485 Setup software. Since EnerVista P485/D485 Setup supports both the P485 and D485 converters, the user must verify that the 'Fieldbus' parameter indicates the correct converter. Additionally, it is possible for advanced users to customize the network interface inside the converter to meet specific application demands (see Advanced fieldbus configuration on page 8–5for details).

Figure 4-5: Fieldbus configuration

P485 MODBUS TO PROFIBUS CONVERTER – USER GUIDE

4–11

Image 33
Contents GE Multilin P485 Modbus to Profibus ConverterPage P485 Modbus to Profibus Converter Table of contentsSoftware Frame Miscellaneous Getting started IntroductionInput and output definition Document conventionsFeatures FeaturesAbout the P485 Modbus to Profibus Converter Mechanical Housing SpecificationsOrdering CommunicationsInstallation Quick installElectrical installation Pin Signal Description Profibus connector pin assignmentsPin Description Configuration cable pin assignments P485 endConfiguration cable PC end Indicators and switches Mechanical installationNumber Description State Status P485 status indicatorsInput/output bytes required Modules Profibus installation procedurePoor performance TroubleshootingOverview Data exchangeMemory Map Address Contents AccessBlocks Protocol configurationData Exchange Installation procedure Software overviewIntroduction Select Configuration Wizard and click on OK Using the EnerVista P485/D485 Setup softwareTypical network arrangement Sub-network data flow Address Command Software Overview P485 Modbus to Profibus Converter User Guide Software Overview Configurator main window Configuration main windowInformation window Function Description Fieldbus configurationP485/D485 configuration P485/D485 configurationParameter Description Range Modbus network configurationSoftware Overview PLC Communication modelP485 scan list Basic settingsMenu NodesCommunication Model P485 Modbus to Profibus Converter User Guide Communication Model Frame editor Frame and command editorsSelect command window Command editorQuery Column Select ‘Add Command’ as described earlierMain window Modbus network monitor Modbus network and node monitorsStart / Stop sub network scanning Node monitor Update OFF Update onCommand Area Control and status registers Advanced functionsCode Name Description Bits Name DescriptionHandshake bits themselves bits 14 Code Error DescriptionFieldbus control system Input/output data during startupMailbox command Advanced fieldbus configurationAdvanced Functions Overview Application exampleType Parameter Address Format Read/write For the MM2, we haveParameter User map data Address Modbus user map setupMM2 meter user map setting System configuration System configurationDB9 pin Description Setup Software Starting Configuration WizardModbus network properties Selecting the SUB-NETWORK PropertiesParameters configured for Pqmii 11 Connect devices to sub-network Connect Devices to the SUB- Network14 Select parameter window Select Parameters for Each Node17 Configuration report Queries 20 Save device file21 Expanding the tree 23 Changing configuration parameters for a query 25 Opening a saved configuration file Profibus network setup Miscellaneous WarrantyRevision history Release Dates10-2 6-3 P485 Modbus to Profibus Converter IndexPower Supply