5.For all 1kVA & (-2) 2-3kVA models, connect the power cord to the UPS inlet located on the UPS rear panel. On (-1) 2 & 3Kva models the line cord is permanently attached to the UPS.

6.Connect the power cord(s) for the equipment to be protected to the UPS output receptacles.

7.For all 2 & 3kVA models remove the two screws securing the battery connector cover plate on the UPS module rear panel. Next remove the two screws securing the upper battery connector cover plate located on the battery module rear panel. Connect one end of the battery interconnect cable to the mating battery connector on the UPS. On the primary battery bank remove the battery fuse and connect the other end of the battery cable to the upper battery connector (located on the battery bank rear panel). Depress and hold the precharge pudhbutton while reinstalling the battery fuse

8.If additional extended battery modules are to be installed, perform the following:

a.Perform the preperation outlined in preceding paragraphs 3a, 3b, abd 3c.

b.Connect the supplied battery interconnect cable(s). Connect one end of the battery interconnect cable to the mating lower battery connector on the first battery module. On extended battery bank, depress the pre-charge pushbutton located on the rear panel, and hold while connecting the other end of the battery cable to the upper extended battery connector (located on the battery bank rear panel). For addition extended battery modules repeat step 8.

BATTERY MODULE INTERCONNECT WIRING

UPS

 

UPS Battery

 

 

Connector

 

 

 

Standard 2 & 3Kva battery Module or Optional 1Kva extended battery module

Battery

Interconnect

Cable

Battery

Interconnect

Cable

Optional extended battery module

Optional extended battery module

Battery

Interconnect

Typical battery fuse

Typical Battery/UPS pre-charge push-

 

Lower cover

button

 

plate shown

 

 

 

 

 

 

6

Image 8
Contents Owners Operating Manual Table of Contents SG Series ON-LINE UPS System Block Diagram Important Safety Instructions Input Power Factor Correction Extended Battery Bank OptionTrue Regenerative On-Line Design Microprocessor ControlSG Rackmount Installation Instructions Rackmount UPS Mounting Instructions --- ImportantNo Battery Backup is Provided When in this Mode Green Mode Disabled Enabled100-120V 200-240V Models OnlyBattery Module Interconnect Wiring UPSPage Optional Slide Mounting KIT Sgrmkit Slide Mounting DetailsSG Rackmount Extended Battery Bank Selection Guide For 1KVA ModelsUPS Front Panel Indicator and Function Keys OperationInverter Indicator LED Category two alarms Audible AlarmsCategory one alarms Front & Rear Panel Details All modelsSG1KRM-1TU SG1KRM-2TUSG2KRM-2TU & SG3KRM-2TU Typical Rear Panel Overview SG2KRM-1TU & SG3KRM-1TUTypical Rear Panel Overview Communications Interfaces LocationSupported Protocols RS-232 InterfaceDRY Contact & Opto Coupler Interface Board Options PIN & Jumper Assignment for the FalconUA88374 Relay Option Board UA88376 Relay Option BoardNo-bypass signal Typical Falcon Opto-coupler Interface CardPIN Assignment for the Falcon UA88373 OPTO-COUPLER Option BoardBattery Replacement Care & MaintenanceBattery Life vs. Temperature Storing the UPS and Batteries FCC ConsiderationsTechnical Support Requesting Technical Information or SupportSUPPORT@FALCONUPS.COM 800.842.6940 Falcon Web SupportLimited NEW Product Warranty Agreement General ProvisionsSG SeriesTM UPS Plus