Installing the
Guidelines for Installation
Locate the C2RPS‐POE within 152 cm (5 ft) of its power source and on a surface as shown in Figure 2‐2.
Caution: To ensure proper ventilation and prevent overheating, leave a minimum clearance space of 5.1 cm (2.0 in.) at the left, right, and rear of the switch.
Do not connect the switch to the AC power source until instructed to do so later in the installation process
Precaución: Para asegurar una buena ventilación y evitar que el sistema se sobrecaliente, deje un espacio mínimo de 5.1 cm (2 pulgadas) con respecto a los lados y a la parte posterior del aparato..
No conecte la fuente del poder a la fuente primaria hasta que no se le indique.
If the switch is being installed as a standalone switch, proceed to “Connecting
C2RPS‐POE Cable and AC Power Cord” on page 2‐7 for power connection instructions.
Figure 2-2 Area Guidelines for C2RPS-POE Installation on Flat Surface
À
|
|
| Á | |
|
|
|
| |
| Ã |
|
|
|
|
|
| Â |
|
1 | Approximately 152 cm (5 ft) from power source | 3 | 49.5 cm (19.5 in.) for proper ventilation | |
2 | 4.45 cm (1.75 in.) per | 4 | 21.5 cm (8.5 in.) for proper ventilation | |
| clearance depends on number of devices |
|
|
|
| stacked.) |
|
|
|