Enterasys Networks C2RPS-CHAS2 manual C2RPS-PSM Power Supply Module, 4 C2RPS-PSM front view

Page 19
C2RPS-PSM Power Supply Module

C2RPS-PSM Power Supply Module

C2RPS-PSM Power Supply Module

The C2RPS‐PSM provides the following:

Hot swap capability.

One 12 Vdc, 150 Watts of maximum‐continuous power output to a connected SecureStack C2 switch device.

Front panel Status LED that indicates if the PSM is operating correctly. Figures 1‐4 and 1‐5 show the front and rear view of the C2RPS‐PSM.

Figure 1-4 C2RPS-PSM (front view)

À Á

C2RPS-PSM

ÂFigure 1-4 C2RPS-PSM (front view)

1Intake cooling fans

2AC power LED

Power Figure 1-5 C2RPS-PSM (rear view)

3Captive screws (2)

Manual backgroundManual backgroundÂ

Figure 1-5 C2RPS-PSM (rear view)

Redundant Power Supply

AC LINE

100-240 VAC

50-60 Hz

2A MAX

 

 

 

 

À

Á

1 Redundant Power Supply connector

2 AC input connector

(12 Vdc inputs and PSM status outputs)

 

 

SecureStack C2 Installation Guide 1-3

Image 19
Contents Installation Guide SecureStack C2 Redundant Power Supply ChassisC2RPS-CHAS2 Page Enterasys Networks, Inc 50 Minuteman Road Andover, MA Industry Canada Notice Regulatory Compliance InformationProduct Safety Federal Communications Commission FCC NoticeVCCI Notice Electromagnetic Compatibility EMCCompatibilidad Electromágnetica EMC Elektro- magnetische Kompatibilität EMCDeclaration of Conformity You and Enterasys agree as follows Enterasys Networks, Inc Firmware License AgreementBEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT CAREFULLY READ THIS LICENSE AGREEMENT3. APPLICABLE LAW. This Agreement shall be interpreted and governed under the laws and in the state and 9. OWNERSHIP. This is a license agreement and not an agreement for sale. You acknowledge and agree that the Program constitutes trade secrets and/or copyrighted material of Enterasys and/or its suppliers. You agree to implement reasonable security measures to protect such trade secrets and copyrighted material. All right, title and interest in and to the Program shall remain with Enterasys and/or its suppliers. All rights not specifically granted to You shall be reserved to Enterasys viii About This Guide ContentsChapter 2 Installation Appendix A SpecificationsC2RPS-CHAS2 Specifications TablesContents of C2RPS-CHAS2 Carton Contents of C2RPS-PSM CartonAbout This Guide How to Use This GuideWho Should Use This Guide Refer to Related DocumentsThe following conventions are used in this guide Conventions Used in This Guidexiv About This Guide Refer to page IntroductionRPS Overview For information aboutFigure 1-3 SecureStack C2RPS-CHAS2 rear view with two PSMs C2RPS-CHAS2 ChassisFigure 1-1 SecureStack C2RPS-CHAS2 front view without PSM Figure 1-2 SecureStack C2RPS-CHAS2 front view with two PSMsFigure 1-4 C2RPS-PSM front view C2RPS-PSM Power Supply ModuleFigure 1-5 C2RPS-PSM rear view Figure 1-6 RPS Supporting Two SecureStack Switches RPS Deployment StrategiesGetting Help 1-6 Introduction Unpacking Chassis and Power Supply Modules InstallationRequired Tools Quantity Installing C2RPS-PSMsTable 2-1 Contents of C2RPS-CHAS2 Carton Table 2-2 Contents of C2RPS-PSM CartonFigure 2-1 C2RPS-PSM Installation Replacing an Installed C2RPS-PSMGuidelines for Rackmount Installation Installing C2RPS-CHAS2 into the RackFigure 2-2 Fastening the C2RPS-CHAS2 to the Rack Rack Mounting the ChassisFigure 2-4 Power Connectors on C2RPS-PSM rear view Connecting the PSM Cables and AC Power CordsFigure 2-3 C2RPS-PSM Cable This completes the installation Figure 2-5 C2RPS-PSM Cable and AC Power Cord Connections2-8 Installation Specification SpecificationsC2RPS-CHAS2 Chassis Specifications Table A-1 C2RPS-CHAS2 SpecificationsFigure A-1 C2RPS-PSM Redundant Power Supply Connector Pin Locations C2RPS-PSM SpecificationsC2RPS-PSM Redundant Power Supply Output Connector Table A-2 C2RPS-PSM SpecificationsFunction Compliance StandardsTable A-3 C2RPS-PSM Redundant Power Supply Connector Pin Functions Pin NumberA-4 Specifications