Installing C2RPS-CHAS2 into the Rack

Installing C2RPS-CHAS2 into the Rack

Note: If you plan to remove and not replace a C2RPS-PSM, immediately reinstall coverplates over any empty power supply slots to prevent EMI leakage from the chassis.

To install a PSM, proceed as follows:

1.Align the PSM with the slot, then slide the PSM forward until its front panel is flush against the chassis front panel.

2.Fasten the PSM to the chassis using the captive screws.

3.Perform steps 1 and 2 for each PSM being replaced. When completed, proceed to Connecting the PSM Cables and AC Power Cords” on page 2‐6.

Installing C2RPS-CHAS2 into the Rack

To install the chassis into a 19‐inch (48.3‐cm) rack, you need four user‐supplied screws to fasten the chassis to the rack rails.

After installing the PSM(s) as described back in Installing C2RPS‐PSMs” on page 2‐2, rack mount the chassis as follows:

1.Refer to the installation guidelines (“Guidelines for Rackmount Installation” on page 2‐4).

2.Install the chassis into the rack (“Rack Mounting the Chassis” on page 2‐5).

3.Connect the PSM cables and AC power cords (“Connecting the PSM Cables and AC Power Cords” on page 2‐6).

Guidelines for Rackmount Installation

The installation site must be within reach of the network cabling and meet the requirements listed below:

Chassis placement close enough to connect the 2‐meter (6.6‐foot) AC power cords from the PSMs to the AC power source.

Up to two three‐pronged power receptacles capable of delivering the current and voltage specified in C2RPS‐PSM Specifications” on page A‐2. Up to two AC outlets on independently‐fused circuits must be within 182 centimeters (6 feet) from the installation site. If there is an AC power source failure, this will prevent the powering down of PSMs due to a single source power failure.

Power cords and type of outlet are dependent on the country. In the United States, one power cord with an NEMA 5‐15P plug is provided with each C2RPS‐PSM.

An ambient temperature of between 5°C (41°F) and 40°C (104°F) must be maintained at the installation site with fluctuations of less than 10°C (18°F) per hour.

2-4 Installation

Image 26
Contents C2RPS-CHAS2 SecureStack C2 Redundant Power Supply ChassisInstallation Guide Page Enterasys Networks, Inc 50 Minuteman Road Andover, MA Federal Communications Commission FCC Notice Regulatory Compliance InformationProduct Safety Industry Canada NoticeElektro- magnetische Kompatibilität EMC Electromagnetic Compatibility EMCCompatibilidad Electromágnetica EMC VCCI NoticeDeclaration of Conformity CAREFULLY READ THIS LICENSE AGREEMENT Enterasys Networks, Inc Firmware License AgreementBEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT You and Enterasys agree as follows3. APPLICABLE LAW. This Agreement shall be interpreted and governed under the laws and in the state and 9. OWNERSHIP. This is a license agreement and not an agreement for sale. You acknowledge and agree that the Program constitutes trade secrets and/or copyrighted material of Enterasys and/or its suppliers. You agree to implement reasonable security measures to protect such trade secrets and copyrighted material. All right, title and interest in and to the Program shall remain with Enterasys and/or its suppliers. All rights not specifically granted to You shall be reserved to Enterasys viii Appendix A Specifications ContentsChapter 2 Installation About This GuideContents of C2RPS-PSM Carton TablesContents of C2RPS-CHAS2 Carton C2RPS-CHAS2 SpecificationsWho Should Use This Guide How to Use This GuideAbout This Guide Related Documents Refer toConventions Used in This Guide The following conventions are used in this guidexiv About This Guide For information about IntroductionRPS Overview Refer to pageFigure 1-2 SecureStack C2RPS-CHAS2 front view with two PSMs C2RPS-CHAS2 ChassisFigure 1-1 SecureStack C2RPS-CHAS2 front view without PSM Figure 1-3 SecureStack C2RPS-CHAS2 rear view with two PSMsFigure 1-5 C2RPS-PSM rear view C2RPS-PSM Power Supply ModuleFigure 1-4 C2RPS-PSM front view RPS Deployment Strategies Figure 1-6 RPS Supporting Two SecureStack SwitchesGetting Help 1-6 Introduction Required Tools InstallationUnpacking Chassis and Power Supply Modules Table 2-2 Contents of C2RPS-PSM Carton Installing C2RPS-PSMsTable 2-1 Contents of C2RPS-CHAS2 Carton QuantityReplacing an Installed C2RPS-PSM Figure 2-1 C2RPS-PSM InstallationInstalling C2RPS-CHAS2 into the Rack Guidelines for Rackmount InstallationRack Mounting the Chassis Figure 2-2 Fastening the C2RPS-CHAS2 to the RackFigure 2-3 C2RPS-PSM Cable Connecting the PSM Cables and AC Power CordsFigure 2-4 Power Connectors on C2RPS-PSM rear view Figure 2-5 C2RPS-PSM Cable and AC Power Cord Connections This completes the installation2-8 Installation Table A-1 C2RPS-CHAS2 Specifications SpecificationsC2RPS-CHAS2 Chassis Specifications SpecificationTable A-2 C2RPS-PSM Specifications C2RPS-PSM SpecificationsC2RPS-PSM Redundant Power Supply Output Connector Figure A-1 C2RPS-PSM Redundant Power Supply Connector Pin LocationsPin Number Compliance StandardsTable A-3 C2RPS-PSM Redundant Power Supply Connector Pin Functions FunctionA-4 Specifications