Enterasys Networks A2H124-24FX manual Installing Optional Mini-GBICs, Preparation

Page 31

Installing Optional Mini-GBICs

Installing Optional Mini-GBICs

This section describes how to install Mini‐GBICs in the SFP port slots 27 and 28 on the A2H124‐24FX. It is recommended that the optional Mini‐GBICs be installed first in a new installation.

Warning: Fiber-optic Mini-GBICs use Class 1 lasers. Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. When viewing the output optical port, power must be removed from the network adapter.

Advertencia: Los Mini-GBICS de fibra optica usan lasers de clase 1. No se debe usar instrumentos opticos para ver la potencia laser. El uso de los instrumentos opticos para ver la potencia laser incrementa el riesgo a los ojos. Cuando vean el puerto de la potencia optica, la corriente debe ser removida del adaptador de la red.

Warnhinweis: Mini-GBICs mit Fiber-Optik Technologie benutzen Laser der Klasse 1. Benutzen sie keinesfalls optische Hilfsmittel, um die Funktion des Lasers zu überprüfen. Solche Hilfsmittel erhöhen die Gefahr von Sehschäden. Wenn sie den optischen Port überprüfen möchten stellen Sie sicher, dass die Komponente von der Spannungsversorgung getrennt ist.

Caution: Carefully follow the instructions in this manual to avoid damaging the Mini-GBIC and the device.

The Mini-GBIC and the device are sensitive to static discharges. Use an antistatic wrist strap and observe all static precautions during this procedure. Failure to do so could result in damage to the Mini-GBIC or the switch. Always leave the Mini-GBIC in the antistatic bag or an equivalent antistatic container when not installed.

Precaución: Siga las instrucciones del manual para no dañar el Mini-GBIC ni del aparato, puesto que son muy sensible a las descargas de electricidad estática. Utilice la pulsera antiestática y tome todas las precauciones necesarias durante este procedimiento. Si no lo hace, podría dañar el Mini-GBIC o del aparato. Mientras no esté instalado, mantenga el Mini-GBIC en su bolsa antiestática o en cualquier otro recipiente antiestático.

Preparation

Before installing the Mini‐GBIC, proceed as follows:

1.Before removing the Mini‐GBIC from the antistatic packaging, it is recommended that you use an antistatic wrist strap (not supplied) to prevent damage from static discharge. To use the wrist strap, refer to the instructions provided with your antistatic wrist strap.

2.Remove the Mini‐GBIC from its packaging.

3.If there is a protective dust cover in the Mini‐GBIC connector, do not remove it at this time.

SecureStack A2 Installation Guide 3-3

Image 31 Contents
SecureStack A2 Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Page Vcci Notice Declaration of Conformity Enterasys NETWORKS, INC Firmware License Agreement Viii Page Page Contents Troubleshooting Figures Xiv Who Should Use This Guide About This GuideRelated Documents How to Use This GuideFollowing conventions are used in this guide Conventions Used in This GuideConventions Used in This Guide Xviii About This Guide Introduction A2H124-24FX OverviewStack Connections Redundant Power Supply CapabilityDescription of Mini-GBICs ConnectivityManagement Lanview Diagnostic LEDsSwitch Configuration Using WebView Switch Configuration Using CLI CommandsSupport@enterasys.com Getting Help 100BASE-FX Multimode Fiber-Optic Network Network Requirements1000BASE-T Twisted Pair Gigabit Ethernet Network 1000BASE-FX Fiber-Optic NetworkHardware Installation Unpacking the Switch Considerations Prior to InstallationRequired Tools Preparation Installing Optional Mini-GBICsInstallation Mini-GBIC with MT-RJ Connector Removing the Mini-GBIC Mini-GBIC with LC ConnectorInstalling the Rubber Feet Installing the Switch on a Flat SurfaceChassis Bottom, Rubber Feet Placement Guidelines for Flat Surface InstallationArea Guidelines for Switch Installation on Flat Surface Guidelines for Rackmount Installation Rack Mounting the SwitchAttaching Brackets and Installing in Rack Attaching the Rackmount Brackets Connecting Stacking CablesStacking Cable Connections About SecureStack A2 Switch Operation in a Stack Configuring Switches in a StackInstalling a New Stackable System of Up to Eight Switches Recommended Procedures for New and Existing StacksImportant Considerations About Using Clear Config in a Stack AC Power Connecting AC and RPS-SYS PowerSwitch Rear View RPS coverplate Screw holes for coverplate C2RPS-SYS Redundant Power SystemStack Initialization Overview What Is Needed Connecting to Console Port for Local ManagementDB9 female connector Serial interface cable Connecting to an IBM or Compatible Device13 Connecting a VT Series Terminal Connecting to a VT Series Terminal14 Connecting to a Modem Connecting to a ModemConnecting to the Network 15 Connecting a Fiber-Optic Cable Segment to MT-RJ Port Connecting Fiber-Optic Cables to MT-RJ Mini-GBIC Ports SecureStack A2 Installation Guide Connecting Fiber-Optic Cables to LC Mini-GBIC Ports Connecting to the Network Connecting UTP Cables to RJ45 Mini-GBIC Ports 16 Four-Wire Crossover Cable RJ45 Pinouts for 10/100BASE-TX TX1+ RX1 TX2+ TX3+ RX3 RX2 TX4+ RX4 Initial Logon to Switch Management Completing the InstallationCompleting the Installation Hardware Installation Troubleshooting Lanview LEDs of A2H124-24FX Using LanviewLED Down RPS Configuration Guide for proper setup Troubleshooting ChecklistConfiguration Guide for the IP address Refer to the SecureStack A2 Reset Password Switch Using the Reset Password SwitchUsing the Reset Password Switch Troubleshooting Specifications Table A-1 A2H124-24FX Switch Specifications Switch SpecificationsTable A-1 A2H124-24FX Switch Specifications Environmental Mini-GBIC Input/Output SpecificationsMGBIC-LC01/MGBIC-MT01 Specifications 1000BASE-SX Gigabit Ethernet SpecificationsMGBIC-LC09 Specifications 1000BASE-LX MGBIC-LC03 Specifications 1000BASE-SXMGBIC-02 Specifications 1000BASE-T MGBIC-08 Specifications 1000BASE-ELXRegulatory Compliance Console Port Pinout AssignmentsRegulatory Compliance Specifications Index Index-2