Using the Reset Switch
Table
Problem | Possible Cause | Recommended Action |
|
|
|
Port(s) goes into | Loop condition detected. | Verify that Spanning Tree is enabled. Refer to the |
standby for no |
| SecureStack B3 Configuration Guide for the instructions to |
apparent reason. |
| set the type of STA. |
|
| Review the network design and delete unnecessary loops. |
|
| If the problem continues, contact Enterasys Networks for |
|
| technical support. |
|
|
|
User parameters | Clear NVRAM was set using | Reenter the lost parameters as necessary. Refer to the |
(IP address, device | CLI commands. | SecureStack B3 Configuration Guide for the instructions to |
and module name, |
| configure the switch using CLI commands. |
etc.) were lost |
| If the problem continues, contact Enterasys Networks for |
when the switch |
| |
| technical support. | |
power was cycled. |
| |
|
| |
|
|
|
Using the Reset Switch
If you forget the switch login password, use the Reset switch to reset the login password to the default password, as described in the following procedure.
Figure 4-3 Reset Switch
À
1Reset switch