Figure 2-5. Basic 2161DS Console Switch Configuration
Network
Digital User
Configuration Port for updating firmware
ARI
Port
Servers
Analog User
Server 1
CAUTION: To reduce the risk of electric shock or damage to your equipment do not disable the power cord grounding plug. The grounding plug is an important safety feature. Plug the power cord into a grounded (earthed) outlet that is easily accessible at all times. Disconnect the power from the unit by unplugging the power cord from either the electrical outlet or the unit.
NOTE: If the building has
NOTE: The maximum supported cable length from switch to server is 10 meters.
To install the 2161DS Console Switch hardware:
1Remove the 2161DS Console Switch unit from the packing material.
2Connect a terminal or PC running terminal emulation software (such as HyperTerminal) to the configuration port on the back panel of the 2161DS Console Switch using the supplied serial cable. The terminal should be set to 9600 baud, 8 bits, 1 stop bit, no parity, and no flow control.
Installation
19