Furuno IF-NMEASC manual Adjustments, LEDs and Equipment Status, LED state and equipment status

Page 12

3.ADJUSTMENTS

3.1LEDs and Equipment Status

The six LEDs above the heading indication light, flash or go off according to equipment status.

GPS OUTPUT PROCESSING

Status LEDs

 

for SC-30

SENSOR1

 

CR33: Status LED for IF-NMEASC

SENSOR2

Heading Pitch Roll

Sentence Bps Output

Interval

Sentence Bps Output

Interval

Menu/ Enter

Cancel

LED state and equipment status

-

+

LED

LED state and equipment status

 

 

GPS

ON: Both GPS antennas in the SC-30 are receiving from five or more satel-

 

lites.

 

OFF: One of the GPS antennas is receiving from 3 or fewer satellites.

 

 

OUTPUT

ON: All data is output from the SC-30 normally.

 

Flashing: Motion (heading, roll, pitch) is output (heave is fixed at 0, position

 

and speed are normal) by dead reckoning.

 

OFF: Heading output is stopped.

 

 

PROCESSING

ON: GPS processor is functioning properly.

 

Flashing: Initializing for GPS.

 

OFF: Not enough satellites received.

 

 

SENSOR1

ON: Rate gyro normal on all three axes.

 

OFF: Rate gyro error.

 

 

SENSOR2

ON: Acceleration sensor normal on all three axes.

 

OFF: Acceleration sensor error.

 

 

CR33

Flashing: Valid NMEA 2000 data is input.

 

ON: No valid NMEA 2000 data is input.

 

OFF: CPU error, or no power.

 

 

4

Image 12
Contents Model IF-NMEASC Page Important Notices Safety Instructions Safety instructions for the operatorIii Table of Contents Foreword Word to the Owner of the IF-NMEASCSystem Configuration Mounting Procedure MountingEquipment List Name Type Code No Qty RemarksWiring Cable construction Adjustments LEDs and Equipment StatusLED state and equipment status Setting Up Nmea Ports Port no Sentence Baud rate bps Tx interval msOutput Processing Sentence Output interval ms Heading, Pitch and Roll Offsets Output ProcessingOperation MAINTENANCE, TROUBLE- Shooting Preventive MaintenanceCheck point Remedy Troubleshooting Symptom Possible trouble RemedyReplacing the Fuse Type Code No FuseSelf Test Self testMemory Clear This page is intentionally left blank Furuno Specifications of Interface Unit IF-NMEASC Jul.2307 R.Esumi Satellite Compass This page is intentionally left blank Page 00016689910